Wall Mounted Mini Split: Heat Pump / Cool Only Models - Available in 1.5 & 2 Tons
Wall Mounted Mini Split: Heat Pump / Cool Only Models - Available in 1.5 & 2 Tons
Wall Mounted Mini Split: Heat Pump / Cool Only Models - Available in 1.5 & 2 Tons
JUBAIL - (013) 341 6666 MADINAH - (014) 846 3771 JEDDAH - (012) 234 3630
RIYADH - (011) 472 5555 YANBU - (014) 321 2151 GIZAN - (017) 321 3915
QASSIM - (016) 364 6198 TABUK - (014) 423 2840 MAKKAH - (012) 546 4167
60Hz
Made
Made in Saudi in KSA
Arabia
Indoor Unit Specifications
Features
INDOOR UNIT MAZ18CCX MAZ18CHX MAZ24CCX MAZ24CHX
Bio Filter MODLE NUMBER*
OUTDOOR UNIT MRZ18CDGCI MRZ18CDGHI MRZ24CDGCI MRZ24CDGHI
MODE OF OPERATION COOL ONLY HEAT PUMP COOL ONLY HEAT PUMP
POWER INPUT - T1, (Watts) / EER 1 1469 / 12.25 1452 / 12.40 1781 / 12.35 1781 / 12.35
POWER INPUT - T3, (Watts) / EER 2 1747 / 8.7 1797 / 8.85 2128 / 8.55 2114 / 8.70
EVAPORATOR AIRFLOW (TURBO/HIGH /MEDIUM / LOW), CFM 710 / 680 / 570 / 520 700 / 640 / 590 / 520 700 / 650 / 600 / 520 735 / 690 / 570 / 510
Long Air Throw +12 Meters Wide Angle Air Throw SOUND PRESSURE LEVEL (1M), dBA 48.5/48/43/40 49/46.5/45.5/40 46.5/44/42/40 51/50/ 45 /40
CONDENSER FAN MOTOR FLA / LRA, AMPS 0.58 / 0.82 0.66/ 0.85
LIQUID - SUCTION - DRAIN PIPE DIA., INCHES 1/4, 5/8, 3/4" 3/8, 5/8, 3/4"
The long air throw of the unit ensures faster The wide angle louvers guides the air is evenly distributed across
air circulation and faster cooling / heating. the room and ensures that air reaches every corner (110O +). MINIMUM CIRCUIT AMPACITY, AMPS(INDOOR / OUTDOOR UNIT) 0.5 / 9.33 0.5/11.0
INDOOR UNIT 14.9 / 18.7 15.1 / 18.8 14.1 / 17.8 15.3 / 19.1
NET/GROSS WEIGHT, KG
OUTDOOR UNIT 47.1 / 51 49.2 / 52.5 60.9 / 65.5 62.5 / 67.3
Health Care (Bio Filter / Carbon Filter): INDOOR UNIT 1080x226x335 1080x226x335
Multi filtration system provides clean and healthier air to users. DIMENSIONS (LxWxH), MM
When air passes through pre filter and bio / carbon filter system, it eliminates bacteria, fungus, dust particles, unpleasant odour and OUTDOOR UNIT 845x363x702 890x342x673 946x410x810
harmful gases.
CONTINUOUS RESEARCH RESULTS IN STEADY IMPROVEMENTS. THEREFORE, THESE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
NOTE: 1. (T1) Cooling capacity and power input data @ 27º C DB / 19°C WB Indoor temperature & 35ºC DB outdoor temperature - ISO 5151 and SASO 2681 / 2663
Hydrophilic Coated Fins: 2. (T3) Cooling capacity and power input data @ 29º C DB / 19°C WB Indoor temperature & 46ºC DB outdoor temperature - ISO 5151 and SASO 2681 / 2663
Since the indoor heat exchanger has lower temperature, it may result in condensation of water drops over fins. By use of coated 3. Heating capacity & power input data @ Indoor 20º C DB / 15º WB Indoor temperature & 7ºC Outdoor temperature.
hydrophilic fins water drops accumulation will be reduced. This improves heat exchanger capacity by reducing air resistance passing At outdoor temperature less than -2 deg C, other source of heating must be used.
through heat exchanger. Thus improve for performance of the unit. 4. Refrigerant charge for outdoor units suitable for 5 meters of interconnecting pipe, for exact charge refer outdoor unit Nameplate.
5. Sound Pressur level is measured at a distance of 1 mtr. In Hemi Anechoic room.
TURBO
Turbo:
NORMAL Turbo feature is used for instant cooling or heating.During Turbo mode the set temperature and fan speeds are preset.