DATE: 2018.8.14
1. Scope:
This specification specifies brushless DC motor for Fan Coil Unit. Motor should meet
Motor can be set constant speed or constant torque working mode by the ToolBox.
2. Motor data
2.1 Rated parameter
Motor Model Voltage Current Output Efficiency Rotation Speed
Power
ZSK88-60-10AA 220Vac 0.75A 60W >75% CW/CCW 1300rpm
Current tolerance: +/-15%
2.2 Limitation Parameters
Input voltage:150Vac-264Vac. When the voltage is less than 150Vac,motor will stop,
When the voltage is more than 264Vac,There has the risk of damage during motor
working.
Maximum output power:Less than 120% of the rating.
2.3 Other motor parameters
Insulation class B
Motor structure IP20
Poles 10P
Operating type S1
Storage temperature(℃) -10~60
Storage humidity(%) ≤RH95
Ambient temperature(℃) -10~45
Ambient humidity(%) ≤RH85
Installation Axial/ horizontal installation
Material
No Part Name Material
1 End Frame 08F/ST12/SPCC/SPCD
2 End Cap 08F/ST12/SPCC/SPCD
3 Ball Bearing 6201ZZ/6202ZZ NSK
4 Magnet Wire 1UEWN/155
5 Stator core 50W800/1000/1300
6 Rotor Core 50W800/1000/1300
8 Shaft 45#
Insulation
15 PA66
Bobbin
100%
6.RoHS
All components conform with RoHS requirements.
Regal Beloit Corporation Proprietary-Do not distribute
www.regalbeloit.com 4
Version:0
7. Producer
Changzhou Regal Beloit (Changzhou) Co.,LTD
Address: No 1 Xin Heng Road, Xin Hua Village, Chun Jiang Town,
Xin Bei District, Changzhou City, Jiangsu Province, China
8. Package
The package of the motor can fully protect the motor in the process of transportation, and
it’s also can avoid the pollution and damp.
9.Reliability
9.1 High temperature test:
1) Stator in 150℃ ambient for 96 hours without applying voltage(not include
plastic cover)
2) Removing the water drops on the motors surface, put motor in normal ambient for
24 hours
load
the rubber in 120ºC 96 hours, the hardness should be less than 58 (Shore A).
9.7 Rotor locking:
When the motor in rotor locking condition, it won’t burn, and the motor will work
10.2 Should cut down power supplier of motor first when motor break down or smokes
10.3 Don’t apply voltage on the motor which high than max voltage
10.5 Don’t plug on/off motor when unit or power supplier is power on.
10.6 Consult to solve issue between both company when found anything can’t involve or