TUBOSER OIL FIELD INSPECTION

SERVICES
8, Rue Elbousten Route de Tunis Km2 3002
Sfax TUNISIA
Tél: (216 74) 239 878
Fax: (216 74) 239 893

MS & MAGNETIC PARTICLE INSPECTION


REPORT
Customer : Weatherford Inspection Report n° : 4886-1993
Work Order n° :81310270 Inspection Date : 04/JANUARY/2017
Work Location : Weatherford Base TRS Expired Date : 03/JULY /2017

Material Description : CONTROL PANEL FRAME


SN: CP0001
TL : 0.96m Width : 0.83m Height : 0.83m
Tare: 460Kg SWL: N/A GW: 460Kg

Inspection Standard : BS EN 12079/WEATHERFORD Procedure Ref : Tuboser MPI inspection Procedure 01


OPERATING MANUAL/ASTME709-08. January 2013 Revision 0/Weatherford Procedure
Inspection Methods : WMPI/VISUAL INSPECTION. Testing Equipment :
-DC Unit 12881 (Calibrated in 23/12/2016)
Inspection Category : MS AC Yoke Lifting Capacity :10lbs
Tested With Bloc Test n°:273 (Calibrated in 26/12/2016)
Inspection Frequency: 12 Months -NDT Chemicals:
White contrast (Pfinder 280 White contrast paint L1101721)
Areas Inspected: Indicated Areas/Stress Area. Black Mag Ink (Pfinder 250 Black Magnetic Ink L1101668)

>Visual Inspection:
-Check for worn: OK
-Check for Damaged : OK
-Check for Corrosion: OK
-Check for any visible cracks: OK
>NDE/MP Inspection According to API RP 8B Category
IV:
Control Panel Frame Wellding area Accepte
d

NDE/MP Inspection of Control Panel Frame


NDE/VISUAL INSPECTION RESULT:
Wellding area
- All critical areas of This Item were MPI inspected and
were found to be free of surface defects at time of
inspection.
Status:

ACCEPTED
Inspected by : KHALIL CHABBOUH
Qualification : ASNT Level II MT PT UT Lev I