XXX Project:

Client:
Case:

Flow Rate For vaporization in the valves outlet Vapours and Liquid Flow
kg/h 95000 Rates and Properties shall be used
Normal/Design
Inlet Pressure
6,4
bar
Outlet Pressure
3,9
LIQUID FLOW

bar
Inlet Temperature
345
°C
Density
772
kg/m3
CV @ Flow Rate
78,691 0
Normal / Design
Valve Size
80 3
mm/inch

Flow Rate
kg/h 430
(Normal/Design)

Inlet Pressure
1,3
bar
Outlet Pressure
1,1
GAS/VAPOUR FLOW

bar
Inlet Temperature
215
°C
k (cp/cv) 1,4

MOLECULAR WEIGHT
18
u.m.a.
CV @ Flow Rate
49,335 0
Normal / Design
Valve Size
80 3
mm/inch

CV @ Flow Rate
128,03 0
VAPORIZATION

Normal / Design
Valve Size
0
mm/inch