facades, exterior soffits or interior walls and ceilings. Installation accessories for Exposed Fastening with Screws or Rivets
Panel layout:
Panels may be installed using visible mechanical Fixing Recommended installation tools
fasteners, such as screws or rivets lacquered the HORIZONTAL VERTICAL SX3-L12, SX3 D12: Screw for mounting on metal
profiles. Drill capacity in aluminum: max. 3 mm
same finish as the panel. The panels are mounted on (1⁄8") and min. 2,5 mm (3⁄32"). Drill capacity in steel:
NATURCLAD-W X X max. 2 mm (5⁄64") and min. 1,5 mm (1⁄16"). Torx and
vertical profiles to create a ventilated chamber behind irius head.
NATURCLAD-B X X
the panels. In the event that the wall is not perfectly
vertically aligned, wall brackets or shims are used to NATURSOFFIT-W X X
SX Centering seat
T25W Adapter E420 Screwdriver
regulate the depth of the channel installation. NATURHARDPANEL-W X X Ensures the concentric insertion of
For SX3 screws with Torx head For SX3 screws with the screw to the panel, as well as
Irius head. its perpendicularity.
12 mm (1⁄2") 12 mm (1⁄2") 32 mm (1 1⁄2")
4,8 mm
6mm 8mm 10mm 12mm 14mm 16mm 18mm 20mm 22mm (.19")
NATURCLAD-W X X X X X X X X X
T20 W Adapter
NATURCLAD-B X X X X X X X X X 12 mm (1⁄2") 38 mm (1 1⁄2")
For TW-S screws with Torx head.
NATURSOFFIT-W X X X X X
SX3-D16 Screw for mounting on metal profiles
NATURHARDPANEL-W X X X X X X X X X specially designed for dry areas. Torx head.
Drill capacity in aluminum: max. 3 mm (1⁄8") and
min. 2,5 mm (3⁄32"). Drill capacity in steel: max.
2 mm (5⁄64") and min. 1,5 mm (1⁄16").
Substructure subframe:
SX Centering seat
Aluminium Ls, T and wall brackets T25W Adapter
For SX3 screws with Torx head Ensures the concentric insertion
of the screw to the panel, as well
16 mm (5⁄8") 30 mm (3⁄16")
as its perpendicularity.
2 3
How to install PARKLEX PRODEMA using exposed fastening with screws or rivets
Assembly instructions: – Acoustic protection: The panels also act as a barrier Dimensional Stability: Minimum Support Points per Panel:
for acoustic waves reducing the amount of noise coming
from the outside, although it doesn’t provide acoustic It must be kept in mind that the exterior panels will be For fastening the screws on PARKLEX PRODEMA panels
insulation properties.
Ventilation behind the panel is required. exposed to changing seasons over the years, and they it is required to do predrilled holes on the panel.
are composed of natural wood. Given that wood is a
For the installation of panels in ventilated façade mode, living material which suffers dimensional variations The distances between supporting points depend on the
the panels are installed on vertical profiles, creating an due to changes in humidity and temperature, it is panel thickness.
interrupted flow of air in the rear part of the panel.
important that the fixings used are the indicated by
Cladding panels must be installed as a ventilated façade; PARKLEX PRODEMA, allowing the panels to move and
therefore, they must be separated from the wall with a not blocking their free expansion and contraction. Distance between fasteners:
L
profiles, which are installed vertically, forming a chamber
E
with a free ventilated space of ≥ 20 mm (3⁄4”), except a
in those countries with specific technical documents. C All our cladding panels are resistant to vapor, water, snow THICKNESS MAXIMUM DISTANCE
Head ventilation:
1220 mm (4')
±0,3%
2440mm (96")
2440mm (96")
B. Vertical metal profile
– Solar protection: Thermal confort is improved inside C. Wall bracket
the building by preventing overheating in the summer, as D. Insulation
E. Screw
it facilitates ‘breathing’ of the façade. This reduces the
L. Metal sheet
amount of thermal energy that reaches the inside of the M. Screen
building. The internal structure is protected from direct a ≥ 20 mm (3⁄4") (except for specific technical documents)
radiation and from the elements
Exception
min. 6 - 8 mm
(1⁄4"- 5⁄16")
4 5
How to install PARKLEX PRODEMA using exposed fastening with screws or rivets
Distance from the edge of the panel to the panel PARKLEX PRODEMA also recommends using either Types of Fasteners:
perforation: GESIPA Accubird PRO CAS, GESIPA Powerbird PRO CAS
or GESIPA Accubird riveting guns to ensure a correct
The distance between the center point of the screw/ rivet application.
and the panel edge must be between 20-40 mm
( 3⁄4”–1 1⁄2”).
SCREW (for dry climates) RIVET
)
Countersunk screws are not allowed:
1 1⁄2" Metal profile Aluminum profile
m (3⁄4"-
0m
20-4 PARKLEX PRODEMA does not allow installing tongue SX3-D16 (5.5 mm x 32 mm) AP16 (5 mm x 18 mm)
and groove panels for exterior façades. This system is Torque of 5Nm (45 lb in)
1 1⁄2"
) fastened using countersunk screws that prevent the
m (3⁄4"-
-40m panels from moving, which is insufficient for the proper
20
functioning of the PARKLEX PRODEMA panels.
)
1 1⁄2"
(3⁄4"-
0mm
20-4
D7
D5
Diameter of holes for Screws or Rivets:
D8
D6
It is also very important for the fixing head to be
completely parallel with the panel surface. Be sure
that the head of the fastener doesn’t make an excesive
pressure on the panel and allows its movement due to
dilatations. It is recommended the use of a depth locator [ Floating point ] [ Floating point ]
during installation.
D5 - 5.5 mm (1⁄4") D7 - 5.1 mm (1⁄4")
D6 - 9.5 mm (3⁄8") D8 - 8.5 mm (11⁄32")
Parallel
Fixed Points
6 Floating Points 7
How to install PARKLEX PRODEMA using exposed fastening with screws or rivets
D3
Cladding Panel
A
Aluminum J Channel
Aluminum HAT Channel
Wall Fixing Screw
Gypsum Wall A
D1 - 5.5mm (1⁄4") D3 - 5.5mm (1⁄4")
D2 - 8.5mm (11⁄32") D4 - 8.5mm (11⁄32") A > 20 mm (3⁄4") A > 20 mm (3⁄4")
8 9
How to install PARKLEX PRODEMA using exposed fastening with screws or rivets
WINDOW SILL
A > 20 mm (3⁄4")
Window
Frame Sill
Sill Channel
WINDOW HEAD
A > 20 mm (3⁄4")
Gypsum Wall A
2 elementos Option A: 5
Option A: 4
Option B: 7
Option B: 6
Cladding Panel
A
Aluminum J Channel
Aluminum HAT Channel
A
1
Panel Fastener Metal
Water Resistant Barrier 3
Wall Fixing Screw
Aluminum J Channel
Aluminum HAT Channel
2 1
Wall Fixing Screw
Water Resistant Barrier Panel Fastener Metal
Ventilation Screen
Window
Gypsum Wall A Frame Head
Gypsum Wall
Aluminum J Channel
EXPOSED INSTALLATION SYSTEM
A
Cladding Panel
JAYS AND HATS
D Cladding Panel Panel Fastener Metal D
Panel Fastener Metal Wall Fixing Screw Aluminum HAT Channel
Water Resistant Steel Backing Plate
Aluminum J Channel Barrier 1. J Profile (1” deep): 10’ Aluminum
Wall Fixing Screw
2. Hat Profile (1” deep): 10’ Aluminum
Water Resistant Barrier 3. Centering Device for SX3 Screws
OPTION A:
Steel Backing Plate
4. SX3 15 L12-5 Irius Screws for Metal - Painted
Gypsum Wall A
5. E-420 Screwing Device for Irius Screws Available panel size
OPTION B: 96" x 48" | 2440 x 1220mm
6. SX3 15-D12-5 TORX Screws for Metal - Painted
7. 11/32” Titanium Coated Twist Drill Bit Panel thickness ≥ 8mm
10 11
How to install PARKLEX PRODEMA using exposed fastening with screws or rivets
5 Option A: 3 Option B: 6
3 4 5
1
2 1
vista general
2 1
How to install PARKLEX PRODEMA using exposed fastening with screws or rivets