AGUA CALIENTE / HOT WATER / EAU CHAUDE / ACQUA CALDA / ÁGUA QUENTE
HIDROCOPPER 18 SLIM (HP 00-02)
2
HIDROCOPPER 18 SLIM+ (HQ 00-01)
UNE EN 14785
3
HIDROCOPPER 24 (HW 00-01)
HIDROCOPPER 24 SLIM (HX 00-01)
UNE EN 14785
4
Español. Página 6
English. Page 28
Français . Page 49
Italiano. Página 72
Português. Página 94
Notas|Notes|Notes|Annotazioni|Anotações
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
06/05/2021
5
Read carefully this manual before using the appliance.
Only that way, the best performance and maximum
safety will be got during its use.
28
INDEX
1.- TECHNICAL FEATURES. Page 30
2.- ADVICE AND RECOMMENDATIONS. Page 31
3.- FUEL. Page 32
4.- INSTALLATION. Page 32
5.- CLEANING AND MAINTENANCE. Page 40
6.- PROBLEMS AND RECOMMENDATIONS. Page 44
7.- WARRANTY. Page 47
8.- ELECTRICAL DRAWING. Page 117
29
1. TECHNICAL FEATURES.
HIDROCOPPER 18 HIDROCOPPER 24
SLIM SLIM+ SLIM
HV 00-03 HW 00-01
HP 00-02 HQ 00-01 HX 00-01
CONNECTIONS
Heating return – ring female “ 3/4 3/4
Safety valve discharge – thread
“ 1/2 1/2
female
Heat flow – thread female “ 3/4 3/4
Charge – Discharge – thread female “ 1/2 1/2
Gas output mm 100 100
Air entrance mm 60 60
AIR ADMISSION
Maximum air flow admission* m /h
3
202.8 237.4
Minimum draught recommended mBar / Pa 10 10
HYDRAULICS
8 L | -10/+100 °C
Expansion vessel
0,75 Bar | 3 Bar máx
Maximum working pressure Bar / KPa 2,2 / 220
Minimum working pressure Bar / KPa 0,8 / 80
Recommended working pressure Bar / KPa 1,2 / 120
Security discharge pressure Bar / KPa 3 / 300
Water volume inside boiler L
GENERAL FEATURES
Weight Kg 133 154 162 171 --
Capacity of the hopper ** Kg 23 36 36 32 40
Noise at level 9, 3 meters in length and 1.5
dB 46 46
meters in height
NOMINAL HEAT OUTPUT
Fuel drop level 1-9 9 9
Nominal heat output kW 18 23,6
Efficiency % 93 92
Consumption kg/h 4 5,1
Approximate autonomy H 6 6 6 6 8
CO content (with O 2 levels of 13%) % 0.02 0,02
Exhaust mass flow g/s 47 55
Average smoke temperature °C 150 150
Auxiliary power consumption W 120 48
REDUCED HEAT OUTPUT
Fuel drop level 1-9 1 1
Reduced heat output kW 9.5 9,5
Efficiency % 95 94
Consumption kg/h 2 2
Approximate autonomy H 12 16 16 16 20
CO content (with O 2 levels of 13%) % 0.02 0,02
Exhaust mass flow g/s 31 28
Average smoke temperature °C 70 90
Auxiliary power consumption W 35 26
30
2. ADVICE AND RECOMMENDATIONS.
2.1. All local regulations, including those referring to national and European standards must be met when installing
the boiler.
2.2. In order to prevent the risk of accident, a correct installation must be done following the instructions of this
manual. Your ECOFOREST distributor will be available to help you and provide you information related to
codes, assembly and installation norms in your area.
2.3. As ECOFOREST do not have direct control on the installation of your stove, ECOFOREST do not guarantee it
and do not bear the responsibility of any damage that could result from a bad use or a bad installation.
2.4. We carefully recommend the heat calculation to be made by a qualified heating engineer.
2.5. We recommend that a confirmed specialist sets up your pellets stove.
2.6. Maintenance work to be carried out at the end of the season or for every 500 kg of fuel burned, as well as any
repairs or equipment modifications, must be performed by authorized personnel.
2.7. The boiler must be installed on floors of sufficient bearing capacity and, if the existing construction does not
allow this, the floor must be adapted and made suitable, for example by fitting a load distribution plate.
2.8. Never use petrol, fuel for lanterns, kerosene nor any similar liquid. Keep this kind of fuel away from your boiler.
2.9. Do not try to turn on your boiler if some glass is broken.
2.10. Make sure the glass door of the fireplace is well closed while the boiler is in operation; also check the cleaning
hatches (if you have touched them).
2.11. Unauthorized modifications are forbidden. Use only spare parts provided by Ecoforest (see exploded view).
2.12. Do not overload the boiler; continuous heating efforts might cause premature aging and damage paint (it is
recommended not to exceed 250°C for gas outlet temperature).
2.13. Do not use the boiler as a burner.
2.14. Consider the configuration of the ANTI-ICING and ANTI-LOCK menus (see user manual). If the stove is not being
used over long periods of time and there is a risk of it freezing, empty the device to avoid breakage.
2.15. To prevent possible electrical shocks, only trained personnel should have access to the sides and the back of
the boiler.
2.16. The hydraulic circuit must always keep open a dissipation circuit greater than 30% of the total installation.
2.17. It is highly advisable to perform regular checks to assess the quality of the water in the system, especially if
more water is being added. If you use a water treatment product, make sure it is compatible with the materials
used in the heating installation. To do so, please contact the product’s manufacturer.
2.18. In order to refill the stove with fuel, the user must open the hopper lid and empty the contents of the fuel tank
carefully, to prevent it from overflowing.
Ensure that the lid is correctly closed after the hopper has been loaded.
In airtight installations, do not open the hopper during operation of the machine.
Hopper lid.
Fuel.
Lock and unlock decorative cover.
Drawing 1
2.19. FIRE IN THE EXHAUST. To prevent this situation from happening, observe the instructions set forth under
section 4 on how to install the gas outlet. What to do:
• The appliance will be turned off due to the excessive temperatures in the exhaust. Do not unplug the stove.
• Call fire brigade.
• The stove must be tested by Chimeney’s sweeps after the soot fire, before it is reused.
31
2.20. The appliance is intended to be permanently connected to water main with a normally closed valve; do not
use a hose-set.
Drawing 2
2.21. Elimination. The stove or boiler cannot be disposed of with household waste when its useful life is over. Please
dispose of the appliance in accordance with the relevant local regulations, in a correct and environmentally
friendly way. Put the product at the end of its useful life in the hands of the waste manager authorized by the
local authorities for transport to a suitable treatment plant.
3. FUEL.
Your stove is designed to operate with wood pellets; however, it can also work with other biomass fuels (ask
your dealer about this). If using a different type of biomass is possible, select it from the fuel selection menu (check
user manual). In most cases, the combustion basket is not the same as for wooden pellets.
ECOFOREST do not have any control on the quality of the fuel you use. For this reason, ECOFOREST cannot
guarantee the full output of your stove nor the eventual premature aging or eventual damage of the gas outlet. The
fuel’s minimum requirements are specified below:
Pellets Olive pits Almond shells
Diameter (mm) 6 —— ——
Length (mm) 5-25 —— ——
Granulometry (mm) —— 3-4 6-8
Calorific value (Kcal/kg) ≥ 4300 ≥ 3800 ≥ 3700
Ash (% mass) < 1.5 < 1.5 < 1.5
Humidity (%mass) < 12 < 12 < 12
Oils — — No oil content — —
Grill and/or specific strangler. ORIGINAL SPECIFIC SPECIFIC
4. INSTALLATION.
The below security distances and assembly diagrams are given for information only as an adaptation shall be
made depending on the norms in force regarding gas outlet, power, security minimum distances specific to geographic
areas.
Air inlets and water connections will be missed in all drawings as section 4.16 indicates the minimum security
distances to be respected for their installation.
ELECTRICAL CONNECTION.
The power socket to which the stove is plugged should meet the following requirements:
4.1. Ground connection must comply with the specific applicable regulations.
4.2. Differential switch with the correct amperage. It must comply with the specific applicable regulations (check
technical specifications of the stove).
32
4.3. Single-phase AC of ~230/240V – 50Hz and pure sine wave.
4.4. The plug must only be connected to a socket with the technical characteristics of the plug in question.
4.5. Easily accessible power socket. If the power socket can’t be accessed due to the characteristics of the electrical
installation, an all-pole disconnection switch must be installed.
4.6. The power cable provided by ECOFOREST is 1.4m long; you might need a longer one. Always use a cable with
ground plug and with an equal or greater section. Make sure the power cable is not placed under the stove or
close to hot or sharp surfaces that could damage it.
Drawing 3
33
• Install the pipe, thereby preventing anyone from
Pipe anchors. OBLIGATORY disassembling or moving the stove or pipe
without tools.
Aluminium belt and silicone of
RECOMMENDABLE • If the pipe is not equipped with sealing rings
high temperature (300°C).
• To compare the pressure of the circuit with which
Pressure gauge. RECOMMENDABLE
the boiler indicates.
• If the stove’s expansion tank is not big enough
Expansion vessel. OBLIGATORY
according to specific calculations.
• Installation of special features such as radiant
floor, areas operated by thermostatic valves,
Buffer tank. RECOMMENDABLE other stoves working in the same site, etc. The
device must be fitted with a buffer tank for proper
regulation.
• Depending on the material used for the hydraulic
Electrolytic sleeve. RECOMMENDABLE
circuit.
Flexible hose for hydraulic
connection resistant to constant RECOMMENDABLE • SLIM and SLIM+ models.
temperatures of 110 °C
Ventillation grills. OBLIGATORY • Insert stoves.
“DIFLUX” piping. OBLIGATORY • AIRTIGHT INSTALLATION "DIFLUX" mounting.
A Lateral wall. ≥E D
Back of the stove. Minimum separation
B that allows visualizing the label ≥ 80 mm
marking the stove.
C 1.5 x depth of stove. See dimensions
D Shelf. ≥ 400 mm
E Depth of stove. See dimensions A
B
E
Drawing 4
4.14. Gas output must be located in a ventilated area, not in closed or half-closed areas e.g. garage, corridor, air
space of the house or places where gas may concentrate.
4.15. The external parts of the stove may reach high temperatures that might burn when touching; it is
recommended to use a non flammable grid to avoid risk of burn for children and old people.
The end of the gas outlet flex should remain higher than the stove’s output. It is mandatory to install at least
two metres in length vertically to create natural current preventing smoke, odors or eventual cut of electric
supply.
The horizontal pipe must not be longer than 1 metre; greater lengths mean ash, condensation or corrosion
may build up in this area.
34
Faced with cut of electric supplies and unusual weather conditions (storms, strong winds) it is recommendable
to install an uninterruptible power supply (UPS) which we have available as an option. This apparatus only
feeds the exhaust vent.
4.16. Distances from doors, Windows, ventilation grids or air input to the house or building:
Drawing 5
4.17. The minimum distance from gas outlet to ground shall be minimum 65cm, depending however on the surface.
Gas may burn grass, plants, trees located near the gas outlet. In the event that the stove outlet is lower, suitable
safety measures should be taken. The outlet pipe should never be below the extractor itself.
4.18. The distance between gas outlet and public pavement shall be minimum 2.20 m. See your local regulations.
4.19. Never fix the gas outlet flex in a chimney or a flex already installed which diameter is 4 times as large as the
stove’s flex (Ø80 max. 200cm2 with flex of Ø100 max. 314 cm2). When installing the stove in higher section the
gas outlet must be channeled to the top.
If the tube that was installed previously was used with another type of heating (wood, oil, etc.), you MUST
clean it thoroughly, to reduce the risk of fire in the gas vent.
4.20. Gas outlet flex cannot be installed in a share pipe such as the pipe of an extractor hood, another stove or
heating system.
4.21. If gas outlet installation is wrong, combustion air’s homogeneity might be bad which could make the wall of
the house or the building dirty, aggregate trash inside the stove and thus be the source of premature
degradation of the spare parts and gas outlet pipe.
4.22. The air input pipe should not be drained with the risk of affecting the correct operation of the stove. For this
reason, and in order to facilitate fresh air input, it is necessary to set up a ventilation grid AT NOT LESS than
50cm both horizontally and vertically from gas output, see point 4.16.
Direct air currents shall also be avoided as they might prevent a correct operation of the stove and as a
consequence, heat performance.
Ventilation of the room must meet the minimum flow required according to specific regulations and the
maximum intake air flow of the machine.
Extraction fans can cause problems when operating in the same room or in the same space as the appliance.
4.23. In any case the design of the chimney termination will impede the free diffusion in the atmosphere of
combustion products. A metallic mesh with a gap of 3x3 cm can be placed to avoid the entry of birds or
unwanted objects.
4.24. If a testing module is installed to collect combustion gas readings and samples, it must be equipped with
hermetic and self-locking sealing.
Although we cannot keep track of or describe every single installation, option, or the local installation
regulations corresponding to your area, Ecoforest guarantees that the installations suggested below will enable
your stove to function properly, and to conform to minimum personal and material safety measures.
If you are installing your stove in a building, in addition to respect local regulations on gas flues, you should
consult with the residents’ association to avoid future problems.
Please read the entire manual carefully, especially the chapter on installation to ensure your stove operates
properly and at full power.
35
If the total pipe length exceeds 8m, it is recommended to increase one measure, being able to make the
whole assembly in the same diameter from the connection of the stove or increase section from 4 m.
4.25. The installation shown below is the most common. Please bear in mind that if the gas flue pipe located on the
outside of the dwelling is in an area where people pass by, insulated tube must be used.
Windbreak.
Stainless steel hose clamp.
T of 135° with outlet.
Insulator.
Wooden ground.
Non flammable floor protection.
Distance equal to or less than 2 metres.
Drawing 6
4.26. If for aesthetic, safety or municipal regulations we cannot install the stove as described above, we can always
install the pipe on the inside of the dwelling, paying special attention to the areas where the pipe touches
structures, and the minimum vertical and maximum horizontal lengths.
Windbreak.
Stainless steel hose clamp.
T of 90° with outlet.
Insulator.
Wooden ground.
Non flammable floor protection.
Elbow of 135°.
Distance equal to or over 2 metres.
MAXIMUM 1 metre.
Drawing 7
4.27. When fitting stoves in brickwork chimneys a perfect seal between the flexible and the rigid pipe must be
achieved. Similarly, the insulation to be placed at the contact areas between the pipe and possibly inflammable
zones must be taken into account. The tube end may be left inside the chimney itself, taking into account its
opening.
Once installation is complete, we must seal the chimney from the inside of the house.
36
Stainless steel hose clamp.
T of 135° with outlet.
Wooden ground.
Non flammable floor protection.
Isolated stainless steel flexible tube.
Rigid flexible pole adapter.
Minimum 200mm.
It must exceed roof height by 1 metre.
If the tube over 8 m in length, the next larger
size will be used.
Drawing 8
4.28. Installing a fitted stove in a brickwork chimney can be done using flexible piping in its entirety, as indicated in
drawing 9. We must take special care when sealing the chimney and gas venting to avoid gas blowing back
during storms.
Stainless steel hose clamp.
T of 135° with outlet.
Wooden ground.
Non flammable floor protection.
Stainless steel flexible tube.
Rigid flexible pole adapter.
Anti blow-back seal.
Minimum 200mm.
It must exceed roof height by 1 metre.
If the tube over 8 m in length, the next larger
size will be used.
Drawing 9
When installing a flexible tube for gas outlet be careful that this is not in contact or close to the circuit board
or combustible material.
Figura 10
37
EXAMPLES OF AIRTIGHT INSTALLATION.
Reduction of the air intake pipe section and gas output section is strictly forbidden.
Ignore section 4.22 in case of airtight installation.
It must be installed in a room with positive atmospheric pressure (minimum 5 pascals). Never make it
work in depression (airtight rooms or without the due air renovations).
Drawing 11
For these installations it is highly advised to modify the depression offset, according to the number of pipe
sections installed. See the following chart:
Drawing 12
* Check modification over the offset with the stove working on level 1 and 9 during 1 hour, controllong the right
combustión of the stove ( no smoke, no depressure excess, etc).
38
It is highly recommended to place a grid in the intake pipe to allow the free air circulation and avoid the
entrance of unwanted objects or little animals like birds.
Purger.
Drawing 14
An Ecoforest box is placed inside the fireplace. It contains the user manual, the installation and maintenance
manual, a keyboard and keyboard support, a WiFi antenna, a power cable, a room sensor and a cleaning brush. The
keyboard must be mounted with its holder.
Drawing 15
39
Screw the WiFi antenna to the docking station. This magnet base must be stuck to the back of the boiler. Once
assembled, the unit has to remain in a vertical position.
Antenna.
Magnet connection base.
Drawing 16
Place the magnet connection base with the antenna where appropriate. When possible, avoid the presence of
metal sheets around the antenna as the WiFi signal might be distorted.
WiFi upper view. WiFi plan view with no metal objects around.
40
Top.
Cleaning lever.
Drawing 17
Drawing 18
WEEKLY MAINTENANCE.
Ash box.
Drawing 19
IMPORTANT: If the boiler is operating while full of ash or residues, that might stretch the burn pot and its
support, the ashtray basket and even the burn pot, being the cause of bad operation or possible breakdown.
41
This is necessary to ensure correct operation and maintain the stove’s life duration. When winter ends, contact
your provider (if he did not contact you) and meet to carry out this maintenance; the following shall be done (the stove
must always be disconnected from power):
5.6. Cleaning of the heat exchanger. CAUTION! THE BOILER MUST BE UNPLUGGED BEFORE THIS OPERATION (very
important).
To access the exchanger, we have to open the lining’s top cover and the cover of the exchanger. Once we have
gained access from the top, we can remove the turbulator.
Pendulums and springs tend to wear, Ecoforest guarantees correct operation and with a minimum loss of
power with wear of up to 50% of their length.
Top cover.
Exchanger cover.
Cylinder of the turbulator.
Positioner.
Helical coupler of the turbulator.
Drawing 20
Cleaning outlet.
Drawing 21
It is recommendable to calculate the frequency with which you clean the outlet cleaning considering the hours
of operation, thus avoiding ash saturation.
Once you clean the walls of the stove, you must be sure that the cleaning outlet is securely closed, since the
proper operation of the stove depends on this cleaning.
5.8. Cleaning of the gas outlet circuit. Always with the boiler disconnected. (Very important).
For an optimal cleaning of the extractor’s collector, it is recommended to dismantle the extractor itself in order
to have full access to this zone for a better cleaning. Once the extractor is dismantled, clean it with a dry brush
and be careful with the turbine and structure.
When reassembling the exhaust it is COMPULSORY to replace the exhaust joint with a new one as you run the
risk of gas entering in our home.
42
Gas outlet extractor.
Drawing 22
5.10. Lubrication of the screw and spring of the gas security valve. It is placed in the right side of the boiler, just
above the cleaning outlet.
Lubrication point.
Drawing 23
5.11. Empty the hopper to take remaining pellets out to avoid pellets absorb humidity.
5.13. Cleaning of dirt which may be accumulated on the inside of the boiler (lower part, components, etc.). You can
access to it by the rear of thereof.
Cleaning brush.
Pipe of pellets fall.
Drawing 24
5.15. Lubrication of the brass tips of the endless shaft’s upper and lower parts with lubricant oil; a small quantity is
enough for all the season. This operation is ONLY recommended in case of noisy.
You get access to the lower tip from inside the hopper, you will see it clearly after removing all pellets.
In order to reach the upper tip, you have to dismantle the endless screw from the back side of the boiler; this
shall be necessary only in case of noise as it has been lubricated at manufacturing, with a high quality lubricant
sufficient for many years.
43
Reducing motor of endless.
Brass fitting and lubrication point.
Drawing 25
5.16. To ensure the proper operation of the safety valve, it must be discharged at the end of each season or once a
year. To manipulate the valve, the rear grille should be removed from the boiler. Once you have access, turn
the thread counterclockwise until the plunger activates the discharge and return it to its initial position.
Warning: The discharge valve must be connected to a drain trap and the water passage must be visible.
Security valve.
Drawing 26
IMPORTANT: After cleaning or fixing, make sure the boiler operates correctly. Once you turn the boiler off or
during the seasons when you do not use it, disconnect the stove to avoid electronic damages.
5.18. Controlling the combustion air inlet and gas outlet; make sure nothing prevents normal circulation (e.g. bird
nests).
5.19. It is recommended to clean the back side of the stove that you reach through the back grids or lateral doors,
in order to take eventual dust away that might have stacked during summer time.
6.1. Do not turn the boiler on and off successively because this might damage the electronical components and
motors ~230/240V - 50Hz.
6.2. Do not touch the boiler while your hands are wet. Though the boiler is equipped with ground plug, it remains
an electric machine that could cause electric discharge if handled incorrectly. A qualified technician only shall
resolve the eventual problems.
6.3. Do not remove any screw of the zones exposed to high temperature before they have been lubricated properly
with lubrication oil.
44
WHAT DO TO IF...
6.4. Make sure the boiler is connected and the plug is leading power.
6.5. Make sure the cable is not damage or cut.
While the boiler is disconnected, dismantle the right door of the boiler and check if any lead of the C.P.U. is
slack.
6.6. Check the C.P.U. pilot. If it is OFF, check also the fuse on the C.P.U.
PELLETS DO NOT FALL AND THE BOILER DOES NOT TURN ON:
Drawing 27
6.12. If the reducer motor receives current and rotate slower than usually, it may have something blocked such as a
screw, a piece of wood, etc. To solve this problem, you must empty the hopper and, even if necessary, to
remove the auger screen.
6.13. If when the reducer motor rotates makes a noisy is due to a lack of lubrication- you have to lubricate only the
auger screen, not the reducer motor, see point 5.15.
45
Burn pot.
Burn pot support.
Resistance air inlet.
Resistance drive.
Start-up resistance.
Resistance tube support.
Screw of resistance.
Resistance support guide.
Resistance support tube, badly fixed.
Resistance support tube, badly fixed.
Start-up resistance, badly fixed.
Resistance support tube; badly fixed.
Drawing 28
6.16. Pay special attention to the cleaning of the boiler as excess of dust may prevent the boiler from starting on.
6.17. Make sure the resistance heats, by moving your finger close to (but not touching) the hole that focuses heat
from the resistance (largest hole in the centre).
THE GAS OUTLET EXTRACTOR DOES NOT WORK OR DOES NOT WORK CORRECTLY:
6.18. Make sure the motor rotates properly by rotating it with your hand (the stove should be disconnected to do
so).
6.19. Check that power reaches the motor, by turning the boiler on.
6.20. Also check the exhaust connection strip and the C.P.U.
6.21. If the boiler accumulates heat and the pump does not move water towards the installation, contact your
dealer.
For the warranty to be considered as valid, the following conditions must be met:
• Hold a proof of purchase or a purchase note that contains the product’s serial number.
• The assembly and start-up of the machine shall be done by an approved technician who considers the
technical characteristics of the installation and connection of the machine; in any case, the installation shall
be done according to the instructions given in the instructions manual provided with the machine.
• The stove is used as indicated in the instructions manual provided with the stove.
• Atmospheric, chemical agents and/or unsuitable use of the product, lack of maintenance, unsuitable
handling or modifications of the product, inefficiency and/or unsuitability of the smoke outlet tube and/or
other causes that do not depend on the product.
• Superheating of the stove due to combustion of unsuitable material that does not correspond to the type
of pellets (wooden pellets) indicated on the manual provided with the stove.
• Transport of the product; it is highly recommended to carefully control the product at receipt and advise
the vendor immediately in case of any damage, by taking note of the anomalies on the transportation
ticket, and making a copy for the transporter. You have 24 hours to bring a written claim to your
distributor/transporter.
• Reimbursements will be accepted only if they have been previously accepted in writing by ECOFOREST, if
the stove is in perfect condition and given back in its original packaging, with a brief explanation of the
problem, copy of the ticket and invoice if you have it, fret paid and a written document stating your
acceptance of those conditions.
• ECOFOREST does not grant any compensation for any direct or indirect damages caused by the product or
resulting from it.
The following will have a limited guarantee of 6 months or 3,000 ignitions (whichever comes first):
• All parts that are subject to wear: the fiber sealing and ceramic glass found at doors, perforated baskets,
parts of the furnace (vermiculite, mullite, etc.), the ignition coil and the exhaust fan turbine (helix).
• Any fixed or movable part of the heater with a cosmetic default that does not affect operation.
47
• Changes in colour, cracks and slight differences in size when it comes to ceramic parts (if the heater or
boiler is equipped with them) cannot be considered a source of complaint, since these are intrinsic qualities
of this type of material.
• The building and/or plumbing works that you might have carried out for the installation of your stove or
boiler.
• For these machines that allow hot water production (thermos/flasks or storage): the pieces related to hot
water installation not provided by ECOFOREST. In the same way, the gauges or regulations of the product
that have to be done because of the type of fuel or due to the characteristics of the installation, are
excluded from the warranty.
• This warranty is valid only for the buyer and cannot be transferred.
• The replacement of pieces does not extend the warranty.
• Compensations will not be granted because of basic inefficiency of the stove or a heating calculation that
was not properly carried out for a determined period of time.
• This is the unique valid warranty and no one is authorized to bring any other on the name or on behalf of
ECOFOREST INTERVENTION DURING THE WARRANTY PERIOD.
• ECOFOREST does not grant any compensation for any direct or indirect damages caused by the product or
resulting from it.
• Modifications to the electrical connections, components or the structure of the stove not authorized by
ECOFOREST.
• Malfunctions or problems caused by non-original components or parts that were nor supplied by
ECOFOREST or its network of distributors.
The intervention query must be sent to the entity which sold the product.
ECOFOREST reserves the right to include modifications in the manuals, warranties and prices without prior
notice.
Any type of suggestion and/or claim must be sent, in writing, to:
Make sure you clearly expose the reason of your demand by bringing all the information necessary to avoid
misunderstanding of your query.
The interventions made within the warranty period include free repair, as per the laws in force.
JURISDICTION:
Both parties, by passing and accepting the order, are submitted to the judges and courts of Vigo (Spain),
expressly excluding any other court, including in case of payment made within another location in Spain or any other
country.
48
8. ESQUEMA ELÉCTRICO / ELECTRICAL DRAWING / SCHEMA ELÉCTRIQUE / SCHEMA
ELETTRICO / ESQUEMA ELÉCTRICO.
117
LEYENDA
LEGEND
LÉGENDE
LEGGENDA
LENDA
Presostato NTC ida Termopar
Pressure switch Heating supply NTC Thermocouple
Pressostat NTC Départ chauffage Thermocouple
Pressostato NTC andata Termocopia
Pressóstato NTC impulsão Termopar
NTC retorno
Return NTC
NTC retour PWM RJ45
NTC ritorno
NTC retorno
Antena WiFI Aire
Antenna WiFI Air
Antenne WiFI LED Air
Antenna WiFI Aria
Antena WiFI Ar
Fusible 3,15 A Cable fuerza Cinta plana
Fuse 3.15 A Power cable Control strip
Fusible 3,15 A Cablage forcé Câble plat
Fusibile 3,15 A Cavo alimentazione Nastro di controllo
Fusível 3,15 A Cabo força Cinta de controlo
Teclado
Keyboard
Clavier --- Micro-USB OTG
Tastiera
Teclado
Azul Rojo Gris
Blue Red Grey
Bleu Rouge Gris
Azzurro Rosso Grigio
Azul Vermelho Cinza
Marrón Negro Termostato rearme
Brown Black Thermostat rearm
Marron Noir Thermostat réarment
Marrone Nero Termostato riattivazione
Castanho Preto Termóstato rearme
Motor reductor Bomba Resistencia de encendido
Motor-reducer Water pump Ignitor
Motéur réducteur Pompe accélétrice Résistenciad’allumage
Motore riduttore Pompa acqua Resistenza di ascensione
Motor redutor Bomba d’água Resistência
Extractor
Exhaust blower
Extracteur
Estrattore
Extractor
118
CONTROL OF THE REVISIONS AND ANNUAL MAINTENANCE.
In order to optimize the functioning of your boiler ECOFOREST it is necessary to carry out the operations of
maintenance detailed in chapter 5 of the instructions manual. Those that shall be done annually must be carried out
by an authorized technician. Contact your distributor so that he sends you the qualified personnel required. Consider
than in order not to lose the warranty of your boiler, you must carry out this annual maintenance and for it to remain
valid, the technician who carries it out must fill in, sign (or stamp) the following forms:
120
Notas|Notes|Notes|Annotazioni|Anotações
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
124
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
125
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
126
POR FAVOR GUARDE LAS INSTRUCCIONES PARA FUTURAS CONSULTAS.
La instalación y el servicio de asistencia técnica deben realizarlas técnicos cualificados.
Reservados todos los derechos. Se prohíbe la reproducción total o parcial de este manual, por cualquier medio, sin el permiso expreso de ECOFOREST. El contenido de este manual
está sujeto a cambios sin previo aviso. El único manual válido es el facilitado por la empresa ECOFOREST.
A pesar de los esfuerzos realizados por asegurar la precisión del contenido de este manual en el momento de la impresión, podrían detectarse errores. Si este es el caso, ECOFOREST
apreciaría enormemente le fueran comunicados. Pese a todo, ECOFOREST no se hace responsable de los errores que puedan aparecer en éste manual.
Todos los manuales de instrucciones están disponibles y actualizados en nuestra página web.
S’IL VOUS PLAÎT CONSERVER LES INSTRUCTIONS POUR LES FUTURES CONSULTATIONS.
L’installation et le service d’assistance technique doivent être réalisés par des techniciens qualifiés. Tous les droits sont réservés. La reproduction entière ou partielle de ce manuel,
par quelque moyen, sans l’autorisation expresse d’ECOFOREST est interdite. Le contenu de ce manuel est sujet à des changements sans préavis. Le seul manuel valide est celui
fourni par l’entreprise ECOFOREST.
Malgré les efforts déployés pour assurer l’exactitude du contenu de ce manuel au moment de l’impression, des erreurs peuvent être détectées. Si tel est le cas, ECOFOREST vous
serait très reconnaissant de les signaler. Néanmoins, ECOFOREST n’est pas responsable des erreurs qui pourraient apparaître dans ce manuel.
Tous les manuels d'instructions sont disponibles et mis à jour sur notre site Web.