The Air Conditioner Not Working

Fault phenomena: Air conditioner does not cool, no air blowing out of the vents

Steps Diagnostic content Failure analysis/treatment

1 Check whether the blower motor fuse Replace the blower motor fuse (F02)
is blown?

2 Check that the A/C control panel switch Replace the A/C control panel
is working properly?

3 Check that the blower motor speed Fault of blower speed control resistor
control resistor is normal?

4 Check for voltage input to the blower Blower motor wiring fault
motor?

5 The above tests are normal, no wind Blower motor fault


blowing out of the system, service or
replace the blower motor.

Fault phenomena: Air conditioner does not cool, air blowing out of vents

Steps Diagnostic content Failure analysis/treatment

1 Check that the A/C control panel A/C A/C switch is not on and compressor is
switch is on? not running.

2 Check the A/C pressure switch? Pressure switch automatically protects


or fails, replace pressure switch

3 Check for blown compressor supply Compressor fuse is blown, replace the
fuse in distribution box? fuse (F11)

4 Check the compressor relay. Replace the distribution box


compressor relay (K8)

5 Check for proper compressor Compressor not running due to poor


grounding? grounding

6 Check for refrigerant. Too little refrigerant, resulting in a


system that does not cool

7 All of the above tests are normal, and Replace the compressor.
the probable cause of failure is an
internal compressor failure, resulting
in no compression.