Fault phenomena: Air conditioner does not cool, no air blowing out of the vents
1 Check whether the blower motor fuse Replace the blower motor fuse (F02)
is blown?
2 Check that the A/C control panel switch Replace the A/C control panel
is working properly?
3 Check that the blower motor speed Fault of blower speed control resistor
control resistor is normal?
4 Check for voltage input to the blower Blower motor wiring fault
motor?
Fault phenomena: Air conditioner does not cool, air blowing out of vents
1 Check that the A/C control panel A/C A/C switch is not on and compressor is
switch is on? not running.
3 Check for blown compressor supply Compressor fuse is blown, replace the
fuse in distribution box? fuse (F11)
7 All of the above tests are normal, and Replace the compressor.
the probable cause of failure is an
internal compressor failure, resulting
in no compression.