Professional Documents
Culture Documents
Official Ncm-Filter-Ampoule Procedures En-Us
Official Ncm-Filter-Ampoule Procedures En-Us
com
©NEOGEN Corporation, 2021. NEOGEN is a registered trademark of NEOGEN Corporation, Lansing, MI 48912 U.S. NCM-Filter-Assay_Procedure_V1
Call 800.234.5333 or visit NEOGEN.com
©NEOGEN Corporation, 2021. NEOGEN is a registered trademark of NEOGEN Corporation, Lansing, MI 48912 U.S. NCM-Filter-Assay_Procedure_V1
NEOGEN® FILTER ASSAY
PLEASE READ INSTRUCTIONS COMPLETELY BEFORE PERFORMING TEST.
Set-up Procedure
1 2 3
Assemble the manifold or filtration Using a gentle twisting motion, Using the same gentle twisting
flask that will supply the secure the funnel adapter into motion, secure the filter onto
vacuum source and complete the rubber stopper. the funnel adapter.
with the rubber stopper.
Test Procedure
1 2 3 4
Remove the filter cover and Briefly remove the filter and Add the culture media onto the Very briefly apply the vacuum so
carefully pour the sample onto its funnel adapter from the top of the filter. When doing so, that the media does not pool on
the filter. Apply the vacuum rubber stopper to release any be careful not to touch the filter top of the filter, and it is visible
just long enough to pull the remaining vacuum pressure. with the tip of the ampoule. underneath the filter.
sample through the filter (if Then, resecure the vacuum Note: The media has been soaked
using a manifold, open only into the stopper. correctly into the filter if there is
one valve at a time). a small pocket of air around the
bottom port. The filter should
be moist, but not oversaturated
or dry.
5 6 7
Remove and appropriately discard Remove filter from the funnel Place the filter into the incubator
the filter plastic funnel. Place adapter, and place a plug on the inverted so that the cover is on
the filter cover over the filter/ open bottom port. the bottom, and incubate for the
base assembly converting the appropriate time and temperature
unit into a petri dish for the for the utilized media.
sample incubation.
©NEOGEN Corporation, 2021. NEOGEN is a registered trademark of NEOGEN Corporation, Lansing, MI 48912 U.S. NCM-Filter-Assay_Procedure_V1