IRCON INTERNATIONAL LIMITED

REINFORCEMENT
UPGRADATION OF RAILWAY LINE FROM MAHO TO OMANTHAI
DETAILS
DETAILS(DIMENSIONS) OF PRECAST PAVERS
BLOCK BLOCK BLOCK BLOCK BLOCK DESIGNATION D & E
DESIGNATION DIMENSIONS DESIGNATION DIMENSIONS

125
125

3Nos. 8MM DIA BARS


5Nos. 8MM DIA BARS
10

450 205
125 125

PAVERS - D
389.7

PAVERS - A 131528Sq.mm.

(Reinforced)

475
205 125

225
10
Area = 0.1315 Sq.m Area = 0.097375 Sq.m
10
125
10

10
125 2 Nos.8 MM DIA BARS
225 125 125 5Nos.8MM DIA BARS
112.5 125

PAVERS - B PAVERS - E
65764Sq.mm.
389.7

(Reinforced)
475

Area = 0.06575 Sq.m Area = 0.059375 Sq.m


10

6Nos.8 DIA BARS 25mm


75 clear cover
125

10 400
10
10

700

6Nos. 8 DIA BARS


450 125
PAVERS - C

700
700

BALLAST
4Nos. 8 DIA BARS

194.9 20050Sq.mm. SEPARATOR


225

70
Area = 0.06575 Sq.m
400

Area = 0.3000 Sq.m


75
10
125
10

10
850

225
112.5 125
PAVERS - B/2
194.9

EDGE
RESTRAINT -F
225
400

Area = 0.032875 Sq.m


Area = 0.3000 Sq.m
REQUIREMENT IN NO.
NOTE:-
1. ALL DIMENSIONS ARE IN MM. PAVER BLOCK- A = 3500 Nos. PAVER BLOCK- D = 1300 Nos.
2. GRADE OF CONCRETE IS M-30 PAVER BLOCK- B = 5800 Nos. PAVER BLOCK- E = 1300 Nos.
3.THE SIZE OF EDGE RESTRAINT MAY CHANGE AS PER THE SITE
REQUIREMENTS. PAVER BLOCK- C = 475 Nos. BALLAST SEPARATOR = 1000 Nos.
PAVER BLOCK- B/2 = 476 Nos. EDGE RESTRAINT- F = 2000 Nos.