Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 16

Footing Pile Cap Design

Project : Footing Number :


1.Input Data SI-Units FPS-Units
Column. width (b) = 0.30478 m 12.0 in
Column. depth (h) = 0.30478 m 12.0 in
2.Material Properties

Rebar fy = 413.8 Mpa 60.0 ksi

Concrete fc' = 20.7 Mpa 3.0 ksi

Modulus of Elasticity steel bars (Es) = 200,000 Mpa 29007.6 ksi


Modulus of Elasticity of Concrete (Ec) = 21,384 Mpa 3101.5 ksi
n = 9

3.Pile data (From Geo-Technical Report)


Pile diameter/width (D) = 0.5 m 19.7 in
safe load of pile (Capacity) = 890 KN 200.0 Kip
length of Pile (L) 12.2 m 480.3 in
4.Loadind Data
Axial Load (Px) = 0 KN 0.0 Kip
Axial Load (Py) 0 KN 0.0 Kip
Axial Load (Pz) 2,669 KN 600.0 Kip
Mx = 0 KN-m 0.0 Kip-ft
My = 0 KN-m 0.0 Kip-ft
Mz = 0 KN-m 0.0 Kip-ft

4. Spring Constant or Point Spring (Kv)


Area of Cross Section of Pile (A) = 0.1963 m2 0.0 in2
Spring Constant (K=(EA/L) = 344,154 KN/m 1965.2 kip/in
Footing Pile Cap Design
Engineer : Date :
5.Pile Arrangement
Required No. of Piles = 3.5
Use number of total pile = 9.0
X - direction FPS-Units Y - direction
number of row 3 number of column
number of pile on each row 3 number of pile on each column
spacing between pile 1.5 m 59.1 in spacing between pile
spacing at edge of footing 0.5 m 19.7 in spacing at edge of footing
total length 4 m 157.5 in total width
dx-1 1.5 m 59.1 in dy-1
dx-2 0 m 0.0 in dy-2
0.75
Download

www.civilmdc.com
Type of Pile cap Footing can be used in this sheet
Y

FPS-Units 11 12
3 X
3 21 22
1.5 m 59.1 in
0.5 m 19.7 in
4 m 157.5 in
1.5 m 59.1 in 11 12 13
0 m 0.0 in X
21 22 23

11 12 13 14
X
21 22 23 24

11 12 13

21 22 23 X

31 32 33

11 12 13 14

21 22 23 24 X

31 32 33 34
Remarks
1 "dx" is the distance from the center of pile to the X-axis (parallel ot Y-axis)
2 "dy" is the distance from the center of pile to the Y-axis (parallel ot X-axis)
3 "d at X-dir" is the distance from the center of pile to the critical section on X-axis
4 "d at Y-dir" is the distance from the center of pile to the critical section on Y-axis
5 if d at X-dir or Y-dir are negative sign, it means that the pile is located inside the critical section
in other words, positive means outside
6 "arm X-dir" is distance in Y-dir to be induced moment about X-axis or Mx
7 "arm Y-dir" is distance in X-dir to be induced moment about Y-axis or My
8 reinforcement in X-dir must be determined by "My" and bar arrangement is located in X-dir
9 reinforcement in Y-dir must be determined by "Mx" and bar arrangement is located in Y-dir
10 input moment "Mx" have to be located in X-dir and always have greater values than "My"
11 when "actual distance" in subject "checking shear" is input, the "sign of the distance have to be check and input follow the "actual value"
ollow the "actual value"
Footing Pile Cap Design
Project : Footing Number :
1.Input Data FPS-Units SI-Units
Column. width (b) = 20 in 0.5 m
Column. depth (h) = 15 in 0.4 m
2.Material Properties

Rebar fy = 72.5 ksi 500.0 Mpa

Concrete fc' = 3.5 ksi 24.1 Mpa

Modulus of Elasticity steel bars (Es) = 29,000 ksi 200000.0 Mpa


Modulus of Elasticity of Concrete (Ec) = 3,372 ksi 23256.3 Mpa
n = 9

3.Pile data (From Geo-Technical Report)


Pile diameter/width (D) = 20 in 0.5 m
safe load of pile (Capacity) = 108 Kip 480.4 KN
length of Pile (L) 540 in 13.7 m
4.Loadind Data
Axial Load (Px) = 0 Kip 0.0 KN
Axial Load (Py) 0 Kip 0.0 KN
Axial Load (Pz) 403 Kip 1792.6 KN
Mx = 0 Kip-ft 0.0 KN-m
My = 0 Kip-ft 0.0 KN-m
Mz = 0 Kip-ft 0.0 KN-m

4. Spring Constant or Point Spring (Kv)


Area of Cross Section of Pile (A) = 314.16 in2 0.20 m2
Spring Constant (K=(EA/L) = 1,962 Kip/in 343571.9 KN/m
Footing Pile Cap Design
Engineer : Date :
5.Pile Arrangement
Required No. of Piles = 4.29
Use number of total pile = 5.0
X - direction SI-Units Y - direction
number of row 3 number of column
number of pile on each row 4 number of pile on each column
spacing between pile 60 in 1.5 m spacing between pile
spacing at edge of footing 20 in 0.5 m spacing at edge of footing
total length 220 in 5.6 m total width
dx-1 60 in 1.5 m dy-1
dx-2 0 in 0.0 m dy-2
30
MODIFIED BY

ENGR. JAHIDUL ISLAM


JS HOMES engineers & consultants
Type of Pile cap Footing can be used in this sheet
Y

SI-Units 11 12
4 X
3 21 22
60 in 1.5 m
20 in 0.5 m
160 in 4.1 m
60 in 1.5 m 11 12 13
0 in 0.0 m X
21 22 23

11 12 13 14
X
21 22 23 24

11 12 13

21 22 23 X

31 32 33

11 12 13 14

21 22 23 24 X

31 32 33 34
Remarks
1 "dx" is the distance from the center of pile to the X-axis (parallel ot Y-axis)
2 "dy" is the distance from the center of pile to the Y-axis (parallel ot X-axis)
3 "d at X-dir" is the distance from the center of pile to the critical section on X-axis
4 "d at Y-dir" is the distance from the center of pile to the critical section on Y-axis
5 if d at X-dir or Y-dir are negative sign, it means that the pile is located inside the critical section
in other words, positive means outside
6 "arm X-dir" is distance in Y-dir to be induced moment about X-axis or Mx
7 "arm Y-dir" is distance in X-dir to be induced moment about Y-axis or My
8 reinforcement in X-dir must be determined by "My" and bar arrangement is located in X-dir
9 reinforcement in Y-dir must be determined by "Mx" and bar arrangement is located in Y-dir
10 input moment "Mx" have to be located in X-dir and always have greater values than "My"
11 when "actual distance" in subject "checking shear" is input, the "sign of the distance have to be check and input follow the "actual value"
ollow the "actual value"