Weekly Cleaning and Sanitation Performance Plant 1

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

Company Name: Document No.

Mogle Bottled Water Manufacturing OF/MBWM/235

Title Weekly Cleaning and Sanitation Performance Report Revision Page 1 of 2


No 00

Date:-_____________________________ Shift:-____

If the activities are performed make it (√) otherwise (X)

S/N Point of Cleaning Cleaning and Sanitation Activities Production Lines Remarks
Line 1 Line 2 Line 3
1 Chlorine Dosing Pump, Brush to remove any debris accumulations,
rinsing effectively and check for proper
Hosing line & Tank
functioning.

2 Sodium Bicarbonate Pump, Brush to remove any debris accumulations, soak


with 500ppm H2O2, rinse effectively and check
Hose & Tank
for residual.
3 Antiscalant Dosing Pump, Brush to remove any debris accumulations, soak
with 500ppm H2O2, rinse effectively and check
Hose Lines & Tank
for residual.
4 Sand Filter Back wash for 25minuts and rinse for 25minuts.
5 Activated Carbon Filter Back wash for 25minuts and rinse for 25 minuts.
6 Softener Tank  Regenerate as per regeneration procedure.
 Back wash for 25 minuts and rinse for
25minuts.
7 1µ Micro Filters Remove out each filter rods, wash manually &
Rinse with Pressurized water.
Flush and Rinse With Pressurized water
8 5µ Micro Filters Remove out each filter rods, wash manually and
Rinse with Pressurized water..
Flush and Rinse With Pressurized water
9 RO Membrane Unit  Conduct membrane CIP as per SOP using
recommended chemicals& concentration.
 Conduct membrane CIP with treated water
only. If possible use hot water at 35oC.
 If microbial growth is observed, soak with
500ppm H2O2 for 30Minuts and Rinse until it
gets free of residue.
10 RO Water Tank Soaking with 500ppm H2O2 for 30Minuts and
Rinse until it gets free of residue.
11 Pure Water Tank Soaking with 500ppm H2O2 for 30Minuts and
Rinse until it gets free of residue.
12 Ozonation Tank Soaking with 500ppm H2O2 for 30Minuts and
Rinse until it gets free of residue.
13 Ozone Generator Filter As per procedure
Titanium Filter  Conduct CIP for the titanium filter rods as
14 per the SOP using recommended chemicals.
 Cleaning with pressurized air and soak with
H2O2 with pure water. Flush and Rinse with
ozonized water
15 Fillers Cleaning fillers as per the SOP and soak with
500ppm H2O2, rinse effectively and check for
residual.
Company Name: Document No.:

Mogle Bottled Water Manufacturing OF/MBWM/235

Title Weekly Cleaning and Sanitation Performance Report Revision Page 2 of 2


No 00

16 Raw Water Reservoirs Washing by brush, soaked for 30’ by H2O2,


rinsing, checking residual chemical
(60m3)
17 Raw Water Reservoirs Washing by brush, soaked for 30’ by H2O2,
rinsing, checking residual chemical
(50m3)
18 Top roof filler machine Mopping, or washing (Clean by
appropriate material)
19 Filler Nozzles Conduct socking with H2o2& rinse by
ozonated Water
20 Preform dust sucker Cleaned by pressurized air

21 Other activities  Clean the conveyer


 Washing the wall
 Mop& Clean Preform hooper and
ozonated cap washer

Remark ______________________________________________________________________________

Prepared By __________________ Checked By __________________


Shift Chemist Senior Chemist

You might also like