Burns 1997
Burns 1997
Liquid circulation in bubble columns influences many system properties such as mass
transfer and catalyst dispersion. Conditionsfavorable for liquid circulation often exist
only for highly turbulent slum'es. Experiments under conditions of lowered su$ace ten-
sion proved conclusively that uniform circulation can exist euen in the bubbly-flow
regime. Moreover, the measured circulating uelocity profile is more plug-shaped in the
center core than traditional models, which take a parabolic shape. These observations
led to the application of a circulation theory based on an energy-dissipationmodel for
turbulent eddy viscosity) which can be easily computed as a simple function of superji-
cial-gas uelocity. Two length scales were used in model calculations depending on flow
regime: bubble diameter for bubbly flow and column diameter for chum turbulence.
The liquid-velocity profile contained a tuned dimensionless proportionality constant,
which resulted in two different average values, k = 2.51 for bubbly flow and 0.0242 for
chum turbulence, when tuned to experimental data. The integral average eddy viscosity
is numerically equivalent to the eddy dispersion coeficient for bubbty flow. Predicted
liquid velocity compared vety favorably with new measured ualues under conditions of
low su$ace tension and with literature values.
Introduction
Bubble-column design is most often concerned with the profiles found in the literature often exhibit plug-shaped pro-
transfer of mass between phases either for separation or to files in the center of the column rather than parabolic, as
supply reactants to a liquid-phase reaction. In either case, a suggested by the predicted values (Hills, 1974; Menzel et al.,
priori knowledge of the mass-transfer characteristics is re- 1990; Ueyama and Miyauchi, 1979). Moreover, this problem
quired for design. However, it is well known that mass ex- is confounded by the lack of reliable liquid velocity data to
change is primarily determined by the global hydrodynamics test new velocity prediction theories. Another problem is the
present in the bubble'column (Shah et al., 1982; Rice et al., lack of detailed information on the system studied with a few
1993). This has been typically represented by correlations notable exceptions (Devanathan et al., 1990,1995; Hills, 1974,
based on system and physical properties. Although useful, 1976; Menzel et al., 1990; Rietema and Ottengraf, 1970; U1-
these correlations do little to elucidate the link between mass brecht and Baykara, 1981; Ueyama and Miyauchi, 1979).
transfer and the overall hydrodynamics on which they are Considering the successful dispersion model of Baird and
founded. Moreover, they do not explain the effect of the in- Rice (19751, a new turbulent (eddy) viscosity is introduced
duced liquid circulation patterns on mass transfer. containing an arbitrary proportionality constant, k. This al-
Attempts have recently been made using turbulent proper- lows, for the first time, a simple calculation of local turbulent
ties, such as Reynolds stresses, to explain the liquid hydrody- viscosity as a function of superficial gas velocity and a length
namics from a fundamental standpoint (Rice and Geary, 1990; scale. The velocity profile may be expressed as a simple alge-
Geary and Rice, 1992; Menzel et al., 1990; Luo and Svend- braic function of this single parameter, k. This parameter was
sen, 1991). These attempts have been somewhat successful, tuned to literature velocity data in both the bubbly-flow and
but the fundamental turbulent parameters, such as Prandtl's chum-turbulent flow regimes. The predicted velocity profiles
length scale and eddy viscosity, have been primarily based on not only fit the data well, but also matched the pluglike shape
single-phase turbulence data. Experimental liquid circulation of the data in the central core of the column. Most other
velocity-prediction models, especially those based on single-
Correspondence concerning this article should be addressed to R. G. Rice. phase turbulence data, yield profiles that are parabolic in
Current address of L. F. Burns: Emon Research and Development Laboratories,
Baton Rouge, LA 70805. shape. The present model is compared to liquid-circulation
(11)
(6)
Core region 5
A2
Buffer region, 6 I5 5 A: Buffer Region ---5
5
A2
Wall Region --5
5
d5
dr, (21)
Experimental Methods
Experiments to assess the voidage and liquid velocity were
where Q is the volumetric liquid flowrate in each of the three conducted to provide a database for comparison to velocity
respective regions. If expressed in terms of the interstitial liq- predictions. Because the column used in this study was per-
uid velocity, the total liquid mass balance becomes fectly aligned, a very stable bubbly-flow operating regime was
produced. As such, the initial experiments with tap-water sys-
tems indicated mainly stable bubbly flow without significant
circulation. Rice and Littlefield (1987) describe a technique
using a visual tracer (an acid-base reaction with phenol-
phthalein present) to gauge column verticality. Both their
column and the column used in this study were mounted on a
single pivot point (a ball bearing), which could be carefully
which after integration by parts, leads to the final constraint tilted in any direction with the help of a spring-loaded caliper
in terms of the defined velocity gradients: system attached halfway up the column (see Figure 5). Ad-
justment to the calipers were made, while the tracer was in-
jected into the column, to ensure a flat, plug-shaped front.
Skewed tracer fronts indicated nonverticality conditions. The
lowest level of axial dispersion corresponded to a “perfectly”
vertical column. Details of this system are given by Rice and
Littlefield (1987); Rice et al. (1990); Geary (1992); and Bums
(1995). The degree of accuracy obtained relative to using a
simple plumb is quite significant, with details described in
These final two constraints (Eqs. 22 and 25) allow implicit Rice and Littlefield (1987). An estimate of the liquid circula-
solutions for 6 and A. For both constraints, the velocity gra- tion was initially gauged using these acid-base dispersion
dient in each of the three regions, not the velocity itself, is tests, which are described in the following subsection.
sufficient to close the system if a specification is made re-
garding the value of the final unknown parameter, k . The
unknown value of the proportionality constant will be tuned Acid - base method
to experimental data taken from literature data and also from The acid-base neutralization technique was originally de-
new liquid circulation data to be presented shortly. signed to infer axial liquid dispersion coefficients. A concen-
Some authors have opted to employ yet another constraint trated base was slowly pumped into the bottom of the bubble
on the bubble column (to solve for unknown parameters), column into a slightly acidic solution containing an indicator,
usually in the form of the energy balance (Anderson and Rice, phenolphthalein. As the alkali reacted with the acid, the so-
1989; Geary, 1992; Ishii, 1975). This yields a balance between lution changed from a clear to a bright pink color, demarcat-
the rate of energy input and the energy dissipation rate in the ing the alkali region from the acidic region. The demarcation
bubble column that is influenced primarily by the interaction between the acid and alkali solutions took the form of a hori-
between phases or the “s1ip”between the gas and the liquid. zontal plane in the noncirculating, vertical bubble column
There is some contention regarding the exact form that the with the clear acid solution above the colored alkali solution.
equations describing the interphase interaction should .take The low level of local mixing in the bubble column tends not
(e.g., the slip force), which yields slightly different energy bal- to disrupt this demarcation plane, also called the line of neu-
ances, depending primarily on the style chosen for the slip tralization (LON), so that the LON slowly rises up the col-
force, F,, and energy dissipation rate (Rietema, 1982; Wallis, umn. Even at high gas flow rates, the LON could be easily
1969; Ishii, 1975). In addition, several expressions for the slip discerned and followed. This pink, alkali solution slowly as-
force exist (see the review article by Shaw et al., 19821, which cends the column, eventually neutralizing all of the acid. By
-
present experiments. The surface tension for all the lowered
surface-tension cases was measured to be 30 dyne/cm.
large surface area (6 mm long by 1 mm in diameter) that
should reduce the effect of small bubbles impacting the probe.
Unfortunately, the steel-clad probe measured both the mean
velocity and velocity fluctuations in all directions. However, it
allowed easy measurements on contaminated (surfactant-
Velocity measurements laced) systems.
Of the two traditional methods of measuring liquid veloc- The Pavlov tube and hot-wire anemometer/steel-clad probe
ity, hot-wire anemometry and the Pavlov tube, the latter were individually calibrated in the bubble column using tap
would not work under lowered surface-tension conditions water and then compared to one another. A representative
-
owing to the amount of surfactant used in the bubble column
(sodium dodecyl sulfate, SDS, concentration 1.475 mg/L
and 0.05% by volume of decyl alcohol). The Pavlov tube (Fig-
comparison plot is shown in Figure 2 for center-line measure-
ments at varying superficial gas velocities. The difference be-
tween the velocity measured by the hot-wire anemometer/
ure 4b) under these lowered surface-tension conditions would steel-clad probe and the Pavlov tube represents the fluctua-
I00
10
I
0. I I 10
0 I 2 3 4 uoc
(CmlS)
-
manometer system used ,a Merium Blue manometer fluid
(s.g. 1.25) to pick up small variations in pressure caused by
the liquid-velocity head. This system is not as accurate for
‘Oidage
Typically, the local voidage or gas holdup is determined
low velocity as is the hot-wire anemometer. This causes some using a conductance probe technique in which an insulated
variation at the low velocities, as seen in Figure 3. needle, exposed only at the tip, is immersed in a bubble field
0 m-:11
/7m
0.6 cm
I cm whether any bubbles had entered the tubing (Burns, 1995).
The hot-wire anemometer was a Dantec 56C17 main bridge
unit with multipurpose signal conditioner, linearizer, and
End View Side View
mean value unit. The steel-clad probe, Dantec catalog num-
ber 55R47, was connected to the unit using a 5-m coaxial
cable. Details of both the steel-clad probe and the Pavlov
tube are given in Figure 4. The unit was connected to a PC
L) Steel Clad
using Notebook for DOS to give automatic data acquisition.
Probe The acrylic bubble column was 13.97 cm internal diameter
and 240 cm in height, and is shown in Figure 5. Both the
Pavlov tube and the steel-clad probe were placed 116 cm up-
ward from the sparger of the column, although not at the
same time. The sparger used in this study was a rubber-sheet
sparger, otherwise known as the Flexisparger. The Flexi-
Figure 4. lsokinetic voidage sampling probe, Pavlov sparger had 151 holes drilled into its face in a 7-mm triangu-
tube, and the hot-wire anemometer/steel-clad lar pitch using a #79 drill bit, which resulted in a mean hole
probe. size of 0.353 mm. The performance of this same Flexisparger
0 IS
Liquid
W
0 10
0 05
0 00
0 01 02 03 04 05 06 07 08 09 1
5
Figure 6. Voidage data from the isokinetic sampling
Xanometer method in lowered surface tension water.
The lines are the fitted staircase model.
Diameter = 13.79 cm
Height = 240 cm
I Circulation velocities, inferred from anemometer measure-
ments, were entirely in the bubbly-flow regime with values as
high as 50 cm/s at the center line (Burns, 1995). Figure 7
shows data and theory for the liquid circulation velocity pro-
files at superficial gas velocities of 1.25 and 2.25 cm/s, both
of which are well within the bubbly-flow regime. Only two
model curves are illustrated to prevent clutter. Results for
__
40
20
3 0
-20
010
‘
I
‘ I
..Uog
l l l
= 6.4cm/sec -40
.Uog = 6.4C ~ S k, = 0.025
Oo5 ~ I1 .Uog
Uog
= 3.8 cm/sec
= 16.9 cdsec -60
000 I 00 01 02 03 04 05 06 07 08 09 10
0 01 02 03 04 05 06 07 08 09 1 5
5 Figure 10. Hills’ (1974) velocity data vs. fitted model for
Figure 9. Hills’ (1974) voidage data for varying U,, (de- U,, of 3.8, 6.4, and 16.9 cm/s (details in
tails in Table 2). Table 2).
Similarly, the buffer and wall region velocity profiles are then,
respectively,
where
and Manuscript received May 31, 1996, and revision receiued Feb. 7, 1997.