$ File d:\Users\NELSON PEDRAZA\Desktop\CARLOS EDUARDO\8-MALIBU\4-SAFE\2-ETAPA III\

2-SAPP\CIM SOT 5.F2K saved m/d/yy h:mm:ss in KN, m, C


SAFE 12.2.0.S
UNITS KN m
$ TITLES
TITLE1 ""
TITLE2 ""
$ GRIDS
GRID "GLOBAL" X "" 10.49841
GRID "GLOBAL" X "" 47.66814
GRID "GLOBAL" Y "" 2.912066
GRID "GLOBAL" Y "" 21.00596
$ BEAM PROPERTIES
BEAMPROP "W18X35" E 1.99948E+08 U 0.3 W 76.97286
BEAMPROP "W18X35" TYPE G A 0.006645148 I 0.000212278 AS 0.0034258 J
2.106131E-07
BEAMPROP "W18X35" DSNSEC 1
BEAMPROP "W18X35" BDESIGN 0.1524 DDESIGN 0.44958 BBDESIGN 0.1524 BFDESIGN
0 DSDESIGN 0
BEAMPROP "W18X35" CT 0.044958 CB 0.044958
BEAMPROP "W18X35" FC 0 FY 0 FYS 0 FCS 0
BEAMPROP "ASEC1-W" E 2.485558E+07 U 0.2 W 0
BEAMPROP "ASEC1-W" TYPE R B 0.25 D 3
BEAMPROP "ASEC1-W" DSNSEC 0
BEAMPROP "ASEC1-W" BDESIGN 0.25 DDESIGN 3
BEAMPROP "ASEC1-W" CT 0.3 CB 0.3
BEAMPROP "ASEC1-W" FC 27579.03 FY 0 FYS 0 FCS 27579.03
BEAMPROP "ASEC1-W" E 2.485558E+07 U 0.2 W 0
BEAMPROP "ASEC1-W" TYPE R B 0.25 D 3
BEAMPROP "ASEC1-W" DSNSEC 0
BEAMPROP "ASEC1-W" BDESIGN 0.25 DDESIGN 3
BEAMPROP "ASEC1-W" CT 0.3 CB 0.3
BEAMPROP "ASEC1-W" FC 27579.03 FY 0 FYS 0 FCS 27579.03
$ SLAB PROPERTIES
$ COLUMN PROPERTIES
$ WALL PROPERTIES
$ SOIL PROPERTIES
$ POINT COORDINATES
$ LINE CONNECTIVITY
LINE "2A7" 11.65093 6.736867 10.49841 16.07681
LINE "2A8" 15.04302 2.93231 14.59793 6.543593
LINE "2A9" 14.49393 7.387408 14.38995 8.231025
LINE "2AA" 14.30433 8.925768 13.62893 14.40567
LINE "2AB" 13.52493 15.24945 13.09048 18.7744
LINE "2AC" 19.91978 3.828852 19.5126 7.146656
LINE "2AD" 19.40904 7.990493 19.23241 9.429695
LINE "2AE" 18.96444 11.61318 18.61684 14.44547
LINE "2AF" 16.25347 15.58482 15.72145 19.91426
LINE "2B0" 16.56454 13.0534 16.70133 11.9403
LINE "2B1" 18.50626 11.65771 21.53356 12.02914
LINE "2B2" 19.84766 13.80535 19.84351 20.75544
LINE "2B3" 24.48995 9.320923 25.01135 5.082971
LINE "2B4" 27.89402 5.437104 27.26209 10.51905
LINE "2B5" 24.5426 12.08686 24.54399 16.55561
LINE "2B6" 24.54425 17.40558 24.54527 20.70563
LINE "2B7" 27.24637 17.4057 27.24766 21.00575
LINE "2B8" 30.91924 17.40591 30.91855 21.00596
LINE "2B9" 29.0864 13.95699 29.08413 17.75578
LINE "2BA" 27.05888 14.60564 27.0606 11.70697
LINE "2BB" 31.11678 11.70707 31.11505 14.60586
LINE "2BC" 27.05926 13.95578 31.11544 13.9582
LINE "2BD" 30.2888 5.435908 30.91463 10.51835
LINE "2BE" 33.16916 5.082348 33.6814 9.321424
LINE "2BF" 33.62577 12.08734 33.62551 16.55604
LINE "2C0" 33.62475 17.40606 33.62411 20.70611
LINE "2C1" 38.2625 3.81555 38.66946 7.146364
LINE "2C2" 38.77256 7.990223 38.94842 9.429521
LINE "2C3" 36.63778 12.02993 39.66511 11.65882
LINE "2C4" 39.21523 11.61322 39.56427 14.46997
LINE "2C5" 38.3255 13.80631 38.32135 20.7564
LINE "2C6" 43.13846 2.912066 43.58169 6.543908
LINE "2C7" 43.68469 7.387949 43.78783 8.231668
LINE "2C8" 43.87247 8.926565 44.5414 14.40783
LINE "2C9" 44.64433 15.2512 45.07527 18.77648
LINE "2CA" 41.91483 15.58615 42.44353 19.91833
LINE "2CB" 41.47002 11.94131 41.60595 13.05511
LINE "2CC" 46.52636 6.72388 47.66814 16.06848
LINE "2CD" 11.15507 10.75529 14.03504 11.11067
LINE "2CE" 44.13897 11.1103 47.01937 10.7588
LINE "2CF" 15.00664 3.227523 19.91978 3.828852
LINE "2D0" 14.49393 7.387408 11.61298 7.04442
LINE "2D1" 12.65576 7.171814 12.8498 5.583465
LINE "2D2" 12.8498 5.583465 13.44537 5.656225
LINE "2D3" 13.44537 5.656225 13.41521 5.904399
LINE "2D4" 13.41521 5.904399 14.65784 6.057553
LINE "2D5" 19.77991 4.968557 24.94783 5.599267
LINE "2D6" 22.06335 3.737065 21.8818 5.225027
LINE "2D7" 19.91978 3.828852 19.96275 3.478785
LINE "2D8" 19.96275 3.478785 22.06359 3.735127
LINE "2D9" 25.01135 5.082971 27.89402 5.437104
LINE "2DA" 24.48995 9.320923 27.3672 9.673813
LINE "2DB" 30.77626 9.394641 27.40191 9.394641
LINE "2DC" 30.2888 5.435908 33.16916 5.082348
LINE "2DD" 33.6814 9.321424 30.81063 9.673779
LINE "2DE" 27.0606 11.70697 31.11678 11.70707
LINE "2DF" 33.23148 5.598043 38.40317 4.966889
LINE "2E0" 36.28301 5.225634 36.09899 3.730466
LINE "2E1" 36.09899 3.730466 38.22019 3.469299
LINE "2E2" 38.22019 3.469299 38.2625 3.81555
LINE "2E3" 38.2625 3.81555 43.17554 3.215962
LINE "2E4" 43.68469 7.387949 46.56559 7.04492
LINE "2E5" 43.5203 6.040875 44.74646 5.889907
LINE "2E6" 44.74646 5.889907 44.71592 5.64178
LINE "2E7" 44.71592 5.64178 45.31142 5.568461
LINE "2E8" 45.31142 5.568461 45.5087 7.170764
LINE "2E9" 44.68916 15.61853 47.57015 15.26651
LINE "2EA" 47.66814 16.06848 46.42284 16.22071
LINE "2EB" 46.42284 16.22071 46.47048 16.61045
LINE "2EC" 46.47048 16.61045 44.83457 16.8101
LINE "2ED" 42.31462 18.86203 45.04493 18.52826
LINE "2EE" 38.32201 19.65715 42.41166 19.65715
LINE "2EF" 38.32201 19.65715 33.62471 19.65706
LINE "2F0" 41.79879 19.65853 41.7994 20.95071
LINE "2F1" 33.62411 20.70611 33.62407 20.95455
LINE "2F2" 33.62407 20.95455 41.7994 20.95071
LINE "2F3" 33.62411 20.70611 30.91861 20.70559
LINE "2F4" 30.91921 17.60591 29.08422 17.60482
LINE "2F5" 29.08422 17.60482 27.24661 17.60538
LINE "2F6" 24.54527 20.70563 27.24755 20.70466
LINE "2F7" 24.54527 20.70563 24.54535 20.95882
LINE "2F8" 15.74819 19.65566 19.84417 19.65811
LINE "2F9" 19.84417 19.65811 24.54495 19.65665
LINE "2FA" 16.37463 19.65571 16.37524 20.96266
LINE "2FB" 16.37524 20.96266 24.54535 20.95882
LINE "2FC" 13.12119 18.52519 15.85081 18.86162
LINE "2FD" 10.57222 15.47867 13.45292 15.83372
LINE "2FE" 11.70396 16.62679 13.33046 16.82726
LINE "2FF" 11.70396 16.62679 11.7524 16.22982
LINE "300" 10.49841 16.07681 11.7524 16.22982
LINE "301" 14.30433 8.925768 19.22054 9.526373
LINE "302" 13.92749 11.98327 15.81964 12.21165
LINE "303" 15.81964 12.21165 15.74141 12.8598
LINE "304" 15.74141 12.8598 16.57574 12.96233
LINE "305" 16.70133 11.9403 18.8918 12.20502
LINE "306" 14.59793 6.543593 14.49393 7.387408
LINE "307" 14.38995 8.231025 14.30433 8.925768
LINE "308" 13.62893 14.40567 13.52493 15.24945
LINE "309" 16.56454 13.0534 16.25347 15.58482
LINE "30A" 18.96444 11.61318 19.22054 9.526373
LINE "30B" 19.22054 9.526373 19.23241 9.429695
LINE "30C" 19.40904 7.990493 19.5126 7.146656
LINE "30D" 24.48995 9.320923 24.5426 12.08686
LINE "30E" 24.5426 12.08686 27.06038 12.08836
LINE "30F" 21.53356 12.02914 24.5427 12.39835
LINE "310" 24.54399 16.55561 24.54425 17.40558
LINE "311" 33.6814 9.321424 33.62577 12.08734
LINE "312" 33.62577 12.08734 31.11655 12.08584
LINE "313" 36.63778 12.02993 33.62575 12.39917
LINE "314" 38.66946 7.146364 38.77256 7.990223
LINE "315" 38.94842 9.429521 39.21523 11.61322
LINE "316" 43.87247 8.926565 43.78783 8.231668
LINE "317" 38.94842 9.429521 43.85952 8.82045
LINE "318" 43.58169 6.543908 43.68469 7.387949
LINE "319" 41.47002 11.94131 39.28817 12.21027
LINE "31A" 41.59315 12.95022 42.42949 12.84725
LINE "31B" 42.42949 12.84725 42.35098 12.20191
LINE "31C" 42.35098 12.20191 44.244 11.97089
LINE "31D" 33.62475 17.40606 33.62551 16.55604
LINE "31E" 41.60595 13.05511 41.91483 15.58615
LINE "31F" 44.5414 14.40783 44.64433 15.2512
$ AREA CONNECTIVITY
$ BEAM ASSIGNS
BEAM "2A7" "W18X35"
BEAM "2A8" "ASEC1-W"
BEAM "2A9" "W18X35"
BEAM "2AA" "W18X35"
BEAM "2AB" "W18X35"
BEAM "2AC" "ASEC1-W"
BEAM "2AD" "W18X35"
BEAM "2AE" "W18X35"
BEAM "2AF" "W18X35"
BEAM "2B0" "W18X35"
BEAM "2B1" "W18X35"
BEAM "2B2" "W18X35"
BEAM "2B3" "W18X35"
BEAM "2B4" "W18X35"
BEAM "2B5" "W18X35"
BEAM "2B6" "W18X35"
BEAM "2B7" "W18X35"
BEAM "2B8" "W18X35"
BEAM "2B9" "W18X35"
BEAM "2BA" "W18X35"
BEAM "2BB" "W18X35"
BEAM "2BC" "W18X35"
BEAM "2BD" "W18X35"
BEAM "2BE" "W18X35"
BEAM "2BF" "W18X35"
BEAM "2C0" "W18X35"
BEAM "2C1" "W18X35"
BEAM "2C2" "W18X35"
BEAM "2C3" "W18X35"
BEAM "2C4" "W18X35"
BEAM "2C5" "W18X35"
BEAM "2C6" "W18X35"
BEAM "2C7" "W18X35"
BEAM "2C8" "W18X35"
BEAM "2C9" "W18X35"
BEAM "2CA" "W18X35"
BEAM "2CB" "W18X35"
BEAM "2CC" "W18X35"
BEAM "2CD" "W18X35"
BEAM "2CE" "W18X35"
BEAM "2CF" "W18X35"
BEAM "2D0" "W18X35"
BEAM "2D1" "W18X35"
BEAM "2D2" "W18X35"
BEAM "2D3" "W18X35"
BEAM "2D4" "W18X35"
BEAM "2D5" "W18X35"
BEAM "2D6" "W18X35"
BEAM "2D7" "W18X35"
BEAM "2D8" "W18X35"
BEAM "2D9" "W18X35"
BEAM "2DA" "W18X35"
BEAM "2DB" "W18X35"
BEAM "2DC" "W18X35"
BEAM "2DD" "W18X35"
BEAM "2DE" "W18X35"
BEAM "2DF" "W18X35"
BEAM "2E0" "W18X35"
BEAM "2E1" "W18X35"
BEAM "2E2" "W18X35"
BEAM "2E3" "W18X35"
BEAM "2E4" "W18X35"
BEAM "2E5" "W18X35"
BEAM "2E6" "W18X35"
BEAM "2E7" "W18X35"
BEAM "2E8" "W18X35"
BEAM "2E9" "W18X35"
BEAM "2EA" "W18X35"
BEAM "2EB" "W18X35"
BEAM "2EC" "W18X35"
BEAM "2ED" "W18X35"
BEAM "2EE" "W18X35"
BEAM "2EF" "W18X35"
BEAM "2F0" "W18X35"
BEAM "2F1" "W18X35"
BEAM "2F2" "W18X35"
BEAM "2F3" "W18X35"
BEAM "2F4" "W18X35"
BEAM "2F5" "W18X35"
BEAM "2F6" "W18X35"
BEAM "2F7" "W18X35"
BEAM "2F8" "W18X35"
BEAM "2F9" "W18X35"
BEAM "2FA" "W18X35"
BEAM "2FB" "W18X35"
BEAM "2FC" "W18X35"
BEAM "2FD" "W18X35"
BEAM "2FE" "W18X35"
BEAM "2FF" "W18X35"
BEAM "300" "W18X35"
BEAM "301" "W18X35"
BEAM "302" "W18X35"
BEAM "303" "W18X35"
BEAM "304" "W18X35"
BEAM "305" "W18X35"
BEAM "306" "W18X35"
BEAM "307" "W18X35"
BEAM "308" "W18X35"
BEAM "309" "W18X35"
BEAM "30A" "W18X35"
BEAM "30B" "W18X35"
BEAM "30C" "W18X35"
BEAM "30D" "W18X35"
BEAM "30E" "W18X35"
BEAM "30F" "W18X35"
BEAM "310" "W18X35"
BEAM "311" "W18X35"
BEAM "312" "W18X35"
BEAM "313" "W18X35"
BEAM "314" "W18X35"
BEAM "315" "W18X35"
BEAM "316" "W18X35"
BEAM "317" "W18X35"
BEAM "318" "W18X35"
BEAM "319" "W18X35"
BEAM "31A" "W18X35"
BEAM "31B" "W18X35"
BEAM "31C" "W18X35"
BEAM "31D" "W18X35"
BEAM "31E" "W18X35"
BEAM "31F" "W18X35"
$ SLAB ASSIGNS
$ COLUMN ASSIGNS
$ WALL ASSIGNS
$ SOIL ASSIGNS
$ RELEASE ASSIGNS
$ LOADS
$ LINEAR STATIC CASES
$ MODAL CASES
$ FUNCTIONS
END
$ END OF MODEL FILE