Professional Documents
Culture Documents
No Load Test 210 Final
No Load Test 210 Final
A B C A B C
AB BC CA AB BC CA
V C V C V C V C V C V C
Stator 1 5.76 0.34 5.73 0.35 5.81 0.3 11.37 0.65 7.71 0.45 7.3 0.4
4 9 3
Stator 2 14.1 0.86 14.2 0.87 14.3 0.8 23.9 1.26 17.4 0.99 17. 1.0
5 5 9 7 4 93 2
Stator 3 12.8 0.78 12.8 0.79 12.6 0.7 22 1.2 15.9 0.91 15. 0.9
6 8 8 7 2 66 1
Stator 4 13.9 0.83 13.6 0.84 13.0 0.7 28.7 1.5 20.9 1.18 20. 1.1
9 2 8 9 5 39 5
Stator 5 5.83 0.35 6.19 0.36 6.08 0.3 11.68 0.64 7.95 0.44 7.9 0.4
5 4 6
DC VOLTAGE, CURRENT AND POWER
Stator 1
Stator 2
Stator 3
Stator 4
Stator 5
@210 rpm
Table 1. The phase voltage and phase current of the generator in delta configuration where in the
stators are connected in series connection.
V C V C V C V C V C V C
57.88 0.51 55.3 0.49 56.6 0.49 48.96 0.65 49.8 0.66 49.22 0.65
@210 RPM
Table 1. The phase voltage and phase current of the generator in delta configuration where in the
stators are connected in parallel connection.
V C V C V C V C V C V C
54.43 0.43 54.23 0.43 56.25 0.44 16.65 0.22 16.11 0.21 15.78 0.21
Table 1. The DC voltage, DC current and DC power of the generator in delta configuration and the
stators are connected in series connection.
Table 1. The DC voltage, DC current and DC power of the generator in delta configuration and the
stators are connected in parallel connection.
Table 1. The DC voltage, DC current and DC power of the generator in which the stators are in
series connection, delta configuration and rectified.
Table 1. The DC voltage, DC current and DC power of the generator in which the stators are in
parallel connection, delta configuration and rectified each.