AC PHASE VOLTAGE & CURRENT

Stator No. Phase Voltage Phase Current

A B C A B C

Stator 1 10.04 10.15 10.24 0.39 0.4 0.4

Stator 2 23.6 22.76 22.88 0.19 0.88 0.88

Stator 3 20.33 20.85 21.05 0.8 0.8 0.81

Stator 4 27.01 26.98 27.91 1.05 1.03 1.05

Stator 5 10.67 10.25 10.89 0.43 0.39 0.41

AC LINE-TO-LINE VOLTAGE AND CURRENT (DELTA CONFIGURATION IN SERIES AND


PARALLEL CONNECTION)

Stator No. ∆ - configuration (series) ∆ - configuration (parallel)

AB BC CA AB BC CA

V C V C V C V C V C V C

Stator 1 5.76 0.34 5.73 0.35 5.81 0.3 11.37 0.65 7.71 0.45 7.3 0.4
4 9 3

Stator 2 14.1 0.86 14.2 0.87 14.3 0.8 23.9 1.26 17.4 0.99 17. 1.0
5 5 9 7 4 93 2

Stator 3 12.8 0.78 12.8 0.79 12.6 0.7 22 1.2 15.9 0.91 15. 0.9
6 8 8 7 2 66 1

Stator 4 13.9 0.83 13.6 0.84 13.0 0.7 28.7 1.5 20.9 1.18 20. 1.1
9 2 8 9 5 39 5

Stator 5 5.83 0.35 6.19 0.36 6.08 0.3 11.68 0.64 7.95 0.44 7.9 0.4
5 4 6
DC VOLTAGE, CURRENT AND POWER

Stator No. Voltage Current Power

Stator 1 10.75 0.57 6.13

Stator 2 23.75 1.14 27.08

Stator 3 21.56 1.2 25.87

Stator 4 27.75 1.53 42.46

Stator 5 11.24 0.6 6.74

DC VOLTAGE, CURRENT AND POWER

Stator No. Voltage Current Power

Stator 1

Stator 2

Stator 3

Stator 4

Stator 5

@210 rpm
Table 1. The phase voltage and phase current of the generator in delta configuration where in the
stators are connected in series connection.

VOLTAGE AND CURRENT (STATORS CONNECTED IN SERIES)

Phase A Phase B Phase C Line AB Line BC Line CA

V C V C V C V C V C V C

57.88 0.51 55.3 0.49 56.6 0.49 48.96 0.65 49.8 0.66 49.22 0.65
@210 RPM
Table 1. The phase voltage and phase current of the generator in delta configuration where in the
stators are connected in parallel connection.

VOLTAGE AND CURRENT (STATORS CONNECTED IN PARALLEL)

Phase A Phase B Phase C Line AB Line BC Line CA

V C V C V C V C V C V C

54.43 0.43 54.23 0.43 56.25 0.44 16.65 0.22 16.11 0.21 15.78 0.21

Table 1. The DC voltage, DC current and DC power of the generator in delta configuration and the
stators are connected in series connection.
Table 1. The DC voltage, DC current and DC power of the generator in delta configuration and the
stators are connected in parallel connection.

DC VOLTAGE, DC CURRENT AND DC POWER OUTPUT (STATORS CONNECTED IN SERIES


AND PARALLEL)

Stators connected in series Stators connected in parallel


Voltage Current Power Voltage Current Power

64.2 0.89 57.13 20.32 0.28 5.68

Table 1. The DC voltage, DC current and DC power of the generator in which the stators are in
series connection, delta configuration and rectified.

Table 1. The DC voltage, DC current and DC power of the generator in which the stators are in
parallel connection, delta configuration and rectified each.

DC VOLTAGE, DC CURRENT AND DC POWER OUTPUT (STATORS CONNECTED IN


PARALLEL AND RECTIFIED EACH)

Stators connected in series Stators connected in parallel


Voltage Current Power Voltage Current Power

21.1 0.18 3.79 70.8 0.9 63.72