VITROS XT 3400 Chemistry System1 Specifications

Measurement Principle: Time for Single Result:


• Colorimetric/Rate • Potentiometric: ~2.5 minutes
• Potentiometric (direct ISEs) • Colorimetric: ~6 minutes
• Immuno-rate • Immuno-rate: ~9 minutes
• Digital Imaging Measuring Technology • Real-time results data stream to LIS available
Reagents: Throughput*:
• No preparation, no mixing or reconstitution required • Maximum theoretical throughput without XT slides:
for Cartridges, Electrolyte Reference Fluid (ERF), up to 755 tests per hour (TPH)
or Immuno-Wash Fluid (IWF) • Maximum theoretical throughput with XT slides:
• Onboard stability up to 35 days up to 1,130 TPH
• Shelf life stability up to 18 months from date • Actual throughput will vary by test mix and
of manufacture sample workflow
• Onboard test capacity:
Sample Types:
–– Up to 5,340 tests (up to 10,680 with XT MicroSlides)
–– 97 reagent/diluent positions: • Serum, Plasma, Urine, CSF

°° 89 MicroSlide Cartridges (18, 50, 60, Sample Volume:


100, or 120 tests/cartridge) • Per assay: 2.7μL
°° 8 Diluent Bottle/Cup Positions
Consumables: Sample Capacity:
• VersaTips and Mixing Cup Arrays can be replenished • Continuous load and unload
without interrupting system operation. Reagents • 80 samples in Universal Sample Trays
replenished without interrupting incubation • Priority STAT tray processing
• Onboard capacity: capability
–– VersaTips: 315 Sample Indices using MicroSensor Technology
–– Mixing Cups: 50 • Detection and flagging of results affected by common
–– ERF: 800 tests interferences (Hemolysis, Icterus, Turbidity)
–– IWF: 300 tests • No Reagents or additional sample volume requirements.
• No additional consumables.
Calibration: • No impact on system workflow
• Up to 25 lots per assay with automatic lot switching
• MicroSlide assays stable up to lot change Sample and Reagent Management Incorporating
• Random-access calibration Intellicheck® Technology:
• Bar-coded calibrators for MicroSlide assays • Single-use Tip Metering verifies sample aspiration
and dispenses, eliminates carryover and addresses
System Startup: cross-contamination concerns
• 24-hour ready mode • Clot, bubble, low and high viscosity, thin layer fluid
• No manual primes, purges, washes or tubing maintenance and short sample detection
• No daily calibrations or calibration checks • Save-the-Sample Clot/Bubble Management
• Liquid level sensing
• MicroSlide and Mixing Cup Array Dispense Verification
• Diluent aspiration and dispense verifications
• Onboard IntelliReport provides complete traceability
and documentation of result quality

*Theoretical maximum. Individual results may vary.

orthoclinicaldiagnostics.com
VITROS XT 3400 Chemistry System1 Specifications
®

Sample Containers: Environment:


• Universal Sample Trays accommodate: • Operating temperature: 15°-30°C/59°-86°F
– 5mL, 7mL, 10mL collection tubes • Ambient relative humidity: 15%-75% RH
– Micro-collection containers • Altitude: up to 2,439 m/8,000 feet
– 0.5mL and 2.0mL cups • Plumbing: No water or drain required; self-contained
onboard waste management eliminates special
Sample Bar Code Identification:
requirements for off-board plumbing
• Autodiscriminates by simultaneously recognizing all
standard symbologies: Communications:
–– Code 128 • Laboratory Information System (LIS):
–– ISBT 128 –– Bidirectional interface for ASTM and HL7 protocols
–– Code 39 –– Broadcast download and Host Query
–– Codabar –– Results can be uploaded individually, as a group,
–– Interleaved 2 of 5 or as an entire sample
• Laboratory Automation System (LAS):
Dilution Capabilities:
–– AT ready at launch
• Auto reflex dilution
–– 1 LAS interface, point-in-space
• Operator requested dilution
• Ports:
• Off-board dilution calculation
–– RS 232 serial ports (for LIS and LAS)
Automatic Reflex Testing (based on user-configuration): –– USB ports (for printers)
• Reflex to different assays –– Ethernet ports (for e-Connectivity®, LIS)
• Reflex to the same assay
e-Connectivity® Interactive System Management:
Operator Interface: • Using the facility’s Internet connection or DSL, SSL
• Color-coded graphical user interface technology establishes a secure connection between
• Ergonomic flat, low-glare, LCD, 17-inch system and Ortho Clinical Diagnostics Technical Support
touchscreen monitor to enhance troubleshooting and increase uptime
• Numeric keypad on monitor • Automatic two-way data exchange to automatically
• Detached keyboard for maximum flexibility send and retrieve data
• Onboard documentation and animated Help (V-Docs) • Automatic download of system software updates
• Onboard maintenance documentation • Remote connectivity provides the ability to enable
remote diagnostics and remote control operation
Data Storage: • Enhance uptime with predictive alerts
• Read/write SSD drive for data input and archiving
• USB flash drive (memory stick) capabilities Acoustic Noise
• 10,000 sample programs • Idle: 57.7dB
• 25,000 samples with ability to archive and retrieve • Operating: 58.9dB
through CD-ROM or USB flash drive
System Dimensions:
• Width: 1.47 m/58.0 inches
• Depth: 0.87 m/34.2 inches
• Height: 1.33 m/52.6 inches
• Weight: 523 kg/1150 pounds
Power:
• Line Voltage: one dedicated 15 amp power line,
nominal 100-240V AC
• Line Frequency: 47-63 Hz