Professional Documents
Culture Documents
Electrical Plan
Electrical Plan
Electrical Plan
A A
A o p o p
A A A
l l
REF
j i g h
k
m
l n
Sm l
Sn
Sij Sgh
Skl
q q
q q
Sopq
B Sef
Sab
B B B
Scd
f d d b b
f
REF
e c a REF
REF
d d b b
f f
q
q q q
C C C C
1 3 5 7 1 3 5 7
TITLE
A A
A A A A
g h b g h
b d d
Sf Se
a c Scd e
f
Sab
b b d d j
i
Sj
Si
s s s s
B B B B
k l
Sk Sl
Spqr
Smno
n o q
p
r
m
C C C C
1 2 3 4 5 6 7 1 2 3 4 5 6 7
TITLE
A A
A A A A
f g
e
b
Se
Sbc
a
Sd Sa
c
h d i
Sh Si
RANGE REF
t t t t
B B B B
j
l n o p s
Spq
Slm
Sk Sr
Sn r
So REF
REF
k
Ss
m
Sj
q
RANGE
RANGE
C C C C
1 2 3 4 5 6 7 1 2 3 4 5 6 7
TITLE
8 REF OUTLET 1 HP 1840 230 8 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE REF OUTLET 1 HP 10 9 REF OUTLET 1 HP
30 AMP
9 REF OUTLET 1 HP 1840 230 8 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
11 REF OUTLET 1 HP
10 REF OUTLET 1 HP 1840 230 8 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE WATT-HOUT METER
11 REF OUTLET 1 HP 1840 230 8 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
BRANCH CKT. NO. LOAD DESCRIPTION VA VOLTS AMPERES CB RATING / AT SIZE OF WIRE & CONDUIT
2 8-100w LIGHTING OUTLET 800 230 3.48 15 2.0 MM² THHN WIRE IN 15MM
13MM ø UPVC PIPE
2 1 22-100wLIGHTING OUTLET
3 CONVE. OUTLET 2520 230 10.95 20 3.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
30 AMP 20 AMP
4 ACU OUTLET 1.5 HP 2300 230 10 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
ACU OUTLET 1.5 HP 4 3 CONVE. OUTLET
5 ACU OUTLET 1.5 HP 2300 230 10 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
30 AMP 30 AMP
6 ACU OUTLET 1.5 HP 2300 230 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
10 ACU OUTLET 1.5 HP 6 5 ACU OUTLET 1.5 HP
7 ACU OUTLET 1.5 HP 2300 230 10 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE 30 AMP
TITLE
BRANCH CKT. NO. LOAD DESCRIPTION VA VOLTS AMPERES CB RATING / AT SIZE OF WIRE & CONDUIT
1 14-100w LIGHTINGOUTLET 1400 230 6.09 15 2.0 MM² THHN WIRE IN 15MM ø UPVC PIPE
SYMBOLS: ELECTRICAL GENERAL NOTES:
2 10-100w LIGHTINGOUTLET 1000 230 4.35 15 2.0 MM² THHN WIRE IN 15MM
13MM ø UPVC PIPE
3 2GANG- CONVE. OUTLET 3600 230 15.65 20 3.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
CEILING LIGHT 1. ALL ELECTRICAL INSTALLATIONS HEREIN AND OTHER RELATED WORKS TO BE DONE IN
4 2GANG- CONVE. OUTLET 2160 230 9.39 20 3.5 MM² THHN WIRE IN 15MM ø UPVC PIPE THIS BUILDING SHALL BE IN ACCORDANCE WITH THE PROVISIONS AND STANDARDS OF
CONVENIENCE OUTLET THE FOLLOWING:
5 ACU OUTLET 1.5 HP 2300 230 10 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
10 REF OUTLET 1 HP 230 8 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
PANEL BOARD - PB
1840
11
1.6 THE EXISTING CITY/MUNICIPAL ORDINANCES AND,
RANGE OUTLET 5000 230 21.74 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
1.7 THE BUREAU OF LABOR STANDARDS.
12 RANGE OUTLET 230 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE CIRCUIT
5000 21.74
2. ALL ELECTRICAL INSTALLATIONS HEREIN SHALL BE DONE UNDER THE DIRECT
HOMERUN
13 RANGE OUTLET 5000 230 21.74 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER. HE SHALL BE RESPONSIBLE
TOTAL 154.7
KILOWATTHOUR IN THE INTERPRETATION OF THE PLANS AND SPECIFICATION AND THE REQUIRED
35580
METER
STANDARDS OF THE ELECTRICAL CODE.
3. MATERIALS AND EQUIPMENT TO BE USED SHALL HAVE INSPECTED COMMODITY
Sa 1 Gang Switch
COMPUTATIONS: MINIMUN CAPACITY OF MAIN FEEDER
CLEARANCE (ICC) LABEL FOR FOREIGN MADE PRODUCTS AND P.S. MARK FOR LOCAL IN
80% ACTUAL LOAD: DEMAND FACTOR = 35580 x 80% = 28464 I= 175AMP (.80)
I= 140 AMP
Sab 2 Gang Switch NATURE OF THE BUREAU OF PRODUCT STANDARD (BPS).
TOTAL CONNECTED LOADS IL = 28464/230 = 123.76 AMPS
FOR MAIN PANEL PROTECTION USED: 3 Gang Switch
4. PROVIDE GROUNDING WIRE TO ALL OUTLETS AND LIGHTING CIRCUITS, ALL NON CURRENT
Sabc
2P-175 AMP ACB
CARRYING METAL PARTS SHALL BE GROUNDED AND BOBDED INCLUDING FENCE AND
FOR MAIN FEEDER WIRE LINE
USED: 2-60 THNN IN 140mm ø PVC PIPE
GATE.
5. ALL PANEL BOARDS, MAIN DISTRIBUTION PANELS, ETC., SHALL HAVE GROUNDING BUS FOR
BRANCH CIRCUITS AND SUB FEEDER GROUNDING SYSTEM SHALL BE BONDED TO THE
MAIN & NEUTRAL FEEDER
2 - 60mm TW WIRE NEAREST METAL WATER PIPE.
ON 140MM ø UPVC PIPE 6. MOUNTING HEIGHT FOR ALL WIRING DEVICES AND PANEL BOARDS SHALL BE.
95MM ø UPVC PIPE
6.1 LIGHTING OUTLETS 1.40M ABOVE FLOOR FINISH.
6.2 CONVENIENCE OUTLETS 0.30M ABOVE FLOOR FINISH.
6.3 TELEPHONE OUTLETS 0.30M ABOVE FLOOR FINISH.
15 AMP 15 AMP 6.4 PANEL BOARDS & CABINETS 1.40M ABOVE FLOOR FINISH.
10-100w LIGHTINGOUTLET 2 1 14-100wLIGHTING OUTLET 7. WIRING METHODS SHALL BE AS FOLLOWS:
7.1 SERVICE ENTRANCE RESISTS INTERMEDIATE METALLIC
20 AMP 20 AMP
CONDUIT (IMC).
2GANG- CONVE. OUTLET 4 3 2GANG- CONVE. OUTLET 7.2 LIGHTING AND POWER SYSTEM POLYVINYL CHLORIDE (PVC).
30 AMP 30 AMP 7.3 TELEPHONE OUTLETS POLYVINYL CHLORIDE (PVC).
ACU OUTLET 1.5 HP 6 5 ACU OUTLET 1.5 HP
7.4 ALL VIBRATING EQUIPMENTS LIQUID TIGHT FLEXIBLE METAL
30 AMP 30 AMP
CONDUIT.
8. NO CHANGES OR MODIFICATION SHALL BE MADE WITHOUT THE DESIGNERS WRITTEN
REF OUTLET 1 HP 8 7 ACU OUTLET 1.5 HP
30 AMP 30 AMP CONSENT.
REF OUTLET 1 HP 10 9 REF OUTLET 1 HP 9. ALL WORKS SHALL BE EXECUTED IN A WORKMANSHIP MANNER AND SHALL PREVENT A
30 AMP 30 AMP NEAT AND ORDERLY ACCEPTANCE. ALL WIRING SHALL BE CONCEALED IN THE LEAST
RANGE OUTLET 12 11 RANGE OUTLET POSSIBLE WAY.
30 AMP
13 RANGE OUTLET
TITLE