Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

SUNPAL POWER

CO., LTD SOLAR CONTROLLER

SOLAR CHARGE
CONTROLLER
CATALOG
SUNPAL POWER
CO., LTD SOLAR CONTROLLER

West Changjiang Road,Shushan District,


Hefei City,Anhui Province,China.

0086-551-65865992
info@sunpalpower.com
www.sunpalpower.com www.sunpalpower.com
SUNPAL POWER CO., LTD SOLAR CONTROLLER

Parameters
Parameter Value
Model ML4860

System voltage 12V/24V/36V/48V Auto

No-load loss 0.7 W ~ 1.2W

Battery voltage 9V ~ 70V

Max. solar input voltage 150V (25°C), 145V (-25°C)

Max. power point voltage range Battery voltage +2V to 120V

Rated charging current 60A

Rated load current 20A

Max. capacitive load capacity 10000uF

800W/12V
1600W/24V
Max. photovoltaic system input power
2400W/36V
3200W/48V

Conversion efficiency ≤98%

MPPT tracking efficiency >99%

compaensation interface
Temperature compensation factor -3mv/°C/2V (default)

Rs485 communicatio
Batter y voltage
Operating temperature -35℃ ~ +45℃

Temperature

interface
sensor
Waterproof level IP32

ML Series 4
3
7
8

2 1
9

5
6
Weight

Communication method
3.6kg

RS232 / RS485
Solar Charge and Discharge Controller Altitude ≤ 3000m

Product dimensions 285×205×93(mm)

ML4860
1 years
Comparison Table of Parameters for Each Type of Battery
Setting Voltage Sealed Lead-Acid Gel Lead-Acid Flooded Lead-Acid
Auto
INPUT
LCD DISPLAY
IP32 Battery Type Battery Battery Battery User (User-Defined)
12V/24V 150V Max.
Overvoltage
Disconnect Voltage 16.0V 16.0V 16.0V 9 ~ 17V

Main Features Equalizing Voltage 14.6V —— 14.8V 9 ~ 17V

Boost Voltage 14.4V 14.2V 14.6V 9 ~ 17V


• With the advanced dual-peak or multi-peak tracking technology, when the solar panel is shadowed or part of the panel fails resulting in
multiple peaks on the I-V curve, the controller is still able to accurately track the maximum power point. Floating Voltage 13.8V 13.8V 13.8V 9 ~ 17V
• A built-in maximum power point tracking algorithm can significantly improve the energy utilization efficiency of photovoltaic systems, and
Boost Restoring
raise the charging efficiency by 15% to 20% compared with the conventional PWM method. Voltage 13.2V 13.2V 13.2V 9 ~ 17V
• A combination of multiple tracking algorithms enables accurate tracking of the optimum working point on the I-V curve in an extremely Low Voltage Disconnect
Restoring Voltage 12.6V 12.6V 12.6V 9 ~ 17V
short time.
Under-Voltage Alarming
• The product boasts an optimum MPPT tracking efficiency of up to 99.9%. Restoring Voltage 12.2V 12.2V 12.2V 9 ~ 17V
• Advanced digital power supply technologies raise the circuit's energy conversion efficiency to as high as 98%. Under-Voltage
Alarming Voltage 12.0V 12.0V 12.0V 9 ~ 17V
• Different charging program options including those for gel batteries, sealed batteries and open batteries, customized ones, etc. are
available. Low Voltage
Disconnect Voltage 11.1V 11.1V 11.1V 9 ~ 17V
• The controller features a limited current charging mode. When the solar panel power exceeds a certain level and the charging current is Discharging Limit
larger than the rated current, the controller will automatically lower the charging power and bring the charging current to the rated level. Voltage 10.6V 10.6V 10.6V 9 ~ 17V
• Instantaneous large current startup of capacitive loads is supported. Over-Discharge
5s 5s 5s 1 ~ 30s
Delay Time
• Automatic recognition of battery voltage is supported.
Equalizing Duration
• LED fault indicators and an LCD screen which can display abnormality information help users to quickly identify system faults. Time
120Min —— 120Min 0 ~ 600Min
• Historical data storage function is available, and data can be stored for up to a year. Equalizing Charging 0 ~ 250D(0 refers to close
30Days 0Days 30Days equalizing charging function)
Interval
• The controller is equipped with an LCD screen with which users can not only check device operating data and statuses, but also modify
controller parameters. Boost Duration Time 120Min 120Min 120Min 10 ~ 600Min
• The controller supports standard Modbus protocol, fulfilling the communication needs of various occasions.

T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com


SUNPAL POWER CO., LTD SOLAR CONTROLLER

Parameters
Parameter Name Parameter Value
Model ML4830

System Voltage 12V/24V/36V/48V Auto

No-Load Loss 0.7 W ~ 1.2W

Battery Voltage 9V ~ 70V

Max Solar Energy Input Voltage <150V

Max Power Point Voltage Scope Battery Voltage +2V ~ 120V

Rated Charging Current 30A

Rated Load Current 20A

Max capacitive load capacity 10000uF

400W/12V
800W/24V
PV System Max Input Power
1200W/36V
1600W/48V

Conversion Efficiency ≤98%

MPPT Tracking Efficiency >99%

Temperature compensation coefficient -3mv/℃/2V(Default)

Temperature
Working Temperature -35℃ ~ +45℃

sensor
ML Series 7
Protection Level IP32
5
4
3 6 Weight 2.3Kg
2 1

Max Wiring Size 25 mm 2


Solar Charge and Discharge Controller
Communication Mode RS485, RS232

Altitude ≤ 3000m

ML4830 Product Size 226×182×81(mm)

5 years

Comparison Table of Parameters for Each Type of Battery


Auto
INPUT
LCD DISPLAY
IP32 Setting Voltage Gelled Lead-Acid
12V/24V 150V Max. Sealed Lead-Acid Open Lead-Acid
Battery Type Battery Battery Battery User (User-Defined)

Overvoltage
Disconnect Voltage 16.0V 16.0V 16.0V 9 ~ 17V
Main Features Equalizing Voltage 14.6V —— 14.8V 9 ~ 17V
• Advanced double-peak or multiple-peak tracking technology. When the panel has a shadow block or a part of the panel is damaged, I-
Boost Voltage 14.4V 14.2V 14.6V 9 ~ 17V
V curve shows multiple peaks. The solar charge controller can still accurately track the maximum power point.
• Built-in algorithm for maximum power tracking. This significantly raises energy utilization efficiency of photovoltaic systems, with charging Floating Voltage 13.8V 13.8V 13.8V 9 ~ 17V
efficiency 15% ~ 20% higher than traditional PWM solar charge controllers.
Boost Restoring
• Combination of multiple tracking algorithms that can track the optimum working point of I-V curve accurately in a very short period of Voltage 13.2V 13.2V 13.2V 9 ~ 17V
time. Low Voltage Disconnect
• MPPT tracking efficiency can be as high as 99.9%. Restoring Voltage 12.6V 12.6V 12.6V 9 ~ 17V
• Advanced digital power technology, with circuit energy conversion efficiency as high as 98%. Under-Voltage Alarming
12.2V 12.2V 12.2V 9 ~ 17V
Restoring Voltage
• Supporting charging procedures of gel batteries, sealed batteries, open batteries, lithium batteries and other types of batteries.①
Under-Voltage
• Current-limiting charging mode. When the power of a solar panel is too large, and the charging current is greater than rated current, the Alarming Voltage 12.0V 12.0V 12.0V 9 ~ 17V
solar charge controller automatically reduces charging power, thereby making the solar panel work at rated charging current. Low Voltage
11.1V 11.1V 11.1V 9 ~ 17V
• Supporting the start of capacitive load instantaneous large current. Disconnect Voltage
• Supporting automatic identification of battery voltage. Discharging Limit
Voltage 10.6V 10.6V 10.6V 9 ~ 17V
• LED indicator of malfunction, buzzer alarm, and liquid crystal display of abnormal information. This helps users identify system failures. Over-Discharge
• Supporting historical data storage for up to 5 years. Delay Time 5s 5s 5s 1 ~ 30s
Equalizing Duration
Time
120Min —— 120Min 0 ~ 600Min
Equalizing Charging 0 ~ 250D(0 refers to close
30Days 0Days 30Days equalizing charging function)
Interval

Boost Duration Time 120Min 120Min 120Min 10 ~ 600Min

T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com


SUNPAL POWER CO., LTD SOLAR CONTROLLER

Parameters
Model ML2420 ML2430 ML2440
System Voltage 12V/24VAuto

No-Load Loss 0.7 W~1.2W

Battery Voltage 9V~35V

Max Solar Energy Input


100V(25℃) 90V(-25℃)
Voltage
Max. power point voltage
Battery Voltage+2V to 75V
range
Rated charging current 20A 30A 40A

Rated load current 20A

Max. capacitive load


capacity 10000uF

260W/12V 400W/12V 550W/12V


Max. photovoltaic system
input power 520W/24V 800W/24V 1100W/24V

Conversion efficiency ≤98%

MPPT tracking efficiency >99%


ML2430/2440 ML2420
Temperature
compensation factor -3mv/℃/2V(default)

Operating temperature -35℃ ~+45℃

Temperature
Protection degree IP32

sensor
ML Series 4
3
7

2 1
5
6
Weight

Communication method
1.4Kg 2Kg

RS232
2Kg

Solar Charge and Discharge Controller Altitude ≤ 3000m

Product dimensions 210×151×59.5(mm) 238×173×72.5(mm) 238×173×72.5(mm)

ML2420/2430/2440
Comparison Table of Parameters for Each Type of Battery
1 years Setting Voltage Sealed Lead-Acid Gelled Lead-Acid
Flooded batter y User (User-Defined)
Batter y Type Batter y Batter y
Auto
INPUT IP32 Overvoltage
16.0V 16.0V 16.0V 9 ~ 17V
12V/24V 100V Max. LCD DISPLAY
Disconnect Voltage

Equalizing Voltage 14.6V —— 14.8V 9 ~ 17V

Boost Voltage 14.4V 14.2V 14.6V 9 ~ 17V


Main Features
Floating Voltage 13.8V 13.8V 13.8V 9 ~ 17V
• With the advanced dual-peak or multi-peak tracking technology, when the solar panel is shadowed or part of the panel fails resulting in
multiple peaks on the I-V curve, the controller is still able to accurately track the maximum power point. Boost Restoring
Voltage 13.2V 13.2V 13.2V 9 ~ 17V
• A built-in maximum power point tracking algorithm can significantly improve the energy utilization efficiency of photovoltaic systems, and
Low Voltage Disconnect
raise the charging efficiency by 15% to 20% compared with the conventional PWM method. Restoring Voltage 12.6V 12.6V 12.6V 9 ~ 17V
• A combination of multiple tracking algorithms enables accurate tracking of the optimum working point on the I-V curve in an extremely Under-Voltage Alarming
Restoring Voltage 12.2V 12.2V 12.2V 9 ~ 17V
short time.
• The product boasts an optimum MPPT tracking efficiency of up to 99.9%. Under-Voltage
Alarming Voltage 12.0V 12.0V 12.0V 9 ~ 17V
• Advanced digital power supply technologies raise the circuit's energy conversion efficiency to as high as 98%.
Low Voltage
• Charging program options are available for different types of batteries including gel batteries, sealed batteries, open batteries, lithium Disconnect Voltage 11.1V 11.1V 11.1V 9 ~ 17V
batteries, etc. Discharging Limit
Voltage 10.6V 10.6V 10.6V 9 ~ 17V
• The controller features a limited current charging mode. When the solar panel power exceeds a certain level and the charging current is
larger than the rated current, the controller will automatically lower the charging power and bring the charging current to the rated level. Over-Discharge
Delay Time 5s 5s 5s 1 ~ 30s
• Instantaneous large current startup of capacitive loads is supported.
Equalizing Duration
• Automatic recognition of battery voltage is supported. Time 120Min —— 120Min 0 ~ 600Min
• LED fault indicators and an LCD screen which can display abnormality information help users to quickly identify system faults. Equalizing Charging
30Days 0Days 30Days
0 ~ 250D(0 refers to close
Interval equalizing charging function)

Boost Duration Time 120Min 120Min 120Min 10 ~ 600Min

T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com


SUNPAL POWER CO., LTD SOLAR CONTROLLER

Parameters
Parameters Value
Model SR-MT2410

System voltage 12V 24V

Max. input power of solar panel 130W 260W

Rated charge/ discharge current 10A

No load loss <15mA

Max. input voltage of solar panel <150V

MPPT tracing efficiency >99%

Over voltage protection 16.5V 33.0V

Limited charge voltage 15.5V 31.0V

Equalizing charge voltage 15.2V 30.4V

Equalizing charge interval 30 days

Boosting charge voltage 14.4V 28.8V

Floating charge voltage 13.8V 27.6V

Over-discharge recover voltage 12.5V 25.0V

Over discharge voltage 11.0V 22.0V


(optional LCD display)
Boosting charge time 2 hours
SETUP

MT Series
Equalizing charge time 1 hour

Over temperature protection Yes

Light-operated voltage (on) 5V


MT Maximum Power Point Tracking Series
Light-operated voltage (off) 6V

Light-operated delay time 5min

MT2410 Working temperature -35℃ ~ +65℃;

Protection level IP64

P
Weight 430g
Pmax
LCD
Auto
IP64 Altitude ≤3000m
INPUT
150V Max. 0 LCD DISPLAY
12V/24V 1s
Dimension 143×71×37.4(mm)

Installation dimension 139×48(mm)


Main Features
• Adopting double crest or multi crest tracing technique, used for the condition when a part of solar panel is under shadow or parts of Load current≥1.25 times rated current, cut off the load within 10 seconds;
solar panel is damage. Overload protection
Load current≥1.5 times rated current, cut off the load within 5 seconds
• Built-in maximum power point tracking algorithm which could promote the energy utilization efficiency of pv system. The charging
efficiency is 15%~20% higher than PWM mode.
• It can find out the best working point of I-V curve within 1 minute. the MPPT efficiency could reach to 99.9%. 1.Reverse connection. 2.Inner over temperature. 3.The voltage of PV input
• Adopting advanced digital power supply techniques which makes the energy conversion efficiency reach up to 97%. Protections terminal is over value. 4.Over load 5.Reverse charging protection at night.
• Four charging stages: MPPT - equalizing charge- boosting charge- floating charge. 6. TVS lightning protection 7. Waterproof: IP 64
• With current-limiting charging mode. When the power of solar panel is oversized, the controller will lower charging power
automatically, which enable the system to work under the rated charging current.
• Have the fault code indication, it helps user confirm the system fault.
• Various load control methods. Could recognize day and night automatically.

T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com


SUNPAL POWER CO., LTD SOLAR CONTROLLER

Parameters
Parameters Value Note

Model HP2430/2440 HP2450/2460 HP4830/4840

Rated current 30A/40A 50A/60A 30A/40A

Automatic recognition of 12V/24V Automatic recognition of


12V/24V/36V/48V Default automatic
System voltage
identification
Manual setup
12V/450W 12V/600W
12V/450W 12V/600W 12V/750W 12V/900W 24V/900W 24V/1200W
Rated power 36V/1800W
24V/900W 24V/1200W 24V/1500W 24V/1800W 36V/1350W
48V/1800W 48V/2400W
The lower the system
No-load loss < 13mA/12V;< 15mA/24V <30mA voltage, the smaller
the no-load loss.
Max. Solar energy
<55V <110V
input voltage
Max. voltage at the
<34V <68V
battery end

Parameters
Battery type Default SLD
HP2450/2460/4830/4840 HP2430/2440 Flooded FLD Sealed SLD GEL GEL Lithium LI

Overvoltage protection 16.0V


Equalizing
charging voltage 14.8V 14.6V – –
Boost charging ×1/12V;
voltage 14.6V 14.4V 14.2V 14.4V
12/24V
×2/24V;

HP Series
AUTO
Solar Charge Controller

Floating charging
voltage 13.8V 13.8V 13.8V –
×3/36V;
USB Charging recovery
voltage 13.2V ×4/48V;
Over-discharge
HP Series Smart Solar Charge Controller recovery voltage 12.5V(settable with the keys)
Over-discharge
voltage 11.0V(settable with the keys)

HP2450/2460/4830/4840/2430/2440
Equalizing
30days – –
charging interval
Equalizing charging
time 1H – –

Boost charging time 2H –


Auto
IP30 Temperature
INPUT 5V 1A
compensation -3.0mV/℃/2V –
12V/24V
LCD DISPLAY PWM 55V Max. over current

Light control voltage Light control on 5V, light control off 6 V (light control on plus 1 V)
×1/12V;×2/24V;
Main Features Light control
judgment time 10minutes
×3/36V;×4/48V;

• Automatic system voltage identification. USB function Yes optional No


• Charging program options for sealed, GEL and flooded lead-acid batteries and lithium batteries are available. optional
Bluetooth fuction
• An upgraded 3-stage PWM charging algorithm is adopted. Application of an equalizing charge to the battery periodically or when over
discharged, can effectively prevent the battery from non-equalization and sulfuration, thus extending the battery's service life (with the Operating temperature -25℃to+55℃;
exception of GEL and lithium batteries).
• With temperature compensation employed, charging parameters can be automatically adjusted (with the exception of lithium batteries). IP protection degree IP30
• A wide range of load working modes facilitate the product's application to different types of street lights and monitoring devices.
• The product provides overcharge, over-discharge, overload protection, as well as short-circuit and reverse-connection protection. Net weight 390g 650g 650g
• By virtue of an advanced load starting method, large-capacitance loads can be started smoothly.
• A range of parameter settings and power-down saving functions are available ,thus requiring no repeated setting. Protection Battery plate reverse connection protection , a battery reverse connection protection , charging battery
board short circuit protection, charging the battery open circuit protection, charging over current protection,
• The product provides a dot matrix graphic LCD screen and a human-machine interface with 2 keys. functions overload protection, load short-circuit protection controller and over temperature protection.
• The user-friendly design of browser and dynamic interfaces ensures convenient and intuitive operations.
• (An optional communication function) provides a RJ12 data port (output of TTL232 level or bluetooth signals), with the data adopting the Dimensions 164.0×103.5×47.0(mm) 189.27×127.2×54.0 (mm) 189.27×127.2×54.0 (mm)
standard Modbus protocol, can be used together with our upper computer monitoring software or mobile phone APP.

T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com


SUNPAL POWER CO., LTD SOLAR CONTROLLER

Parameters
Parameters Value
Model SR-HP2410 SR-HP2420

Rated current 10A 20A

System voltage Automatic recognition of 12 V/ 24 V

Dimensions 103×71×36(mm) 130×75×38(mm)

No-load loss < 5mA/12V;< 10mA/24V

Max. Solar energy input voltage <55V

Max. voltage at the battery end <35V

Overvoltage protection 17.0V;×2/24V;

Equalizing charging voltage 14.6V;×2/24V;

Boost charging voltage 14.4V;×2/24V;

Floating charging voltage 13.8V;×2/24V;

Charging recovery voltage 13.2V;×2/24V;


HP2420 HP2410
Over-discharge recovery voltage 12.6V;×2/24V;

Over-discharge voltage 11.1V;×2/24V;

Equalizing charging interval 30 days

Equalizing charging time 1H

HP Series
Boost charging time 2H

Temperature compensation -3.0mV/℃/2V

Light control voltage Light control on 5V, ×2/24V; light control off 6V
HP Series Smart Solar Charge Controller
Light control judgment time 1minute

Operating temperature -25℃ to +55℃;

HP2420/2410 IP protection degree IP30

Net weight 100g 160g

Solar panel short circuit and reverse-connection protection


Auto
IP30 Protection functions
INPUT 5V 1A
12V/24V
LCD DISPLAY PWM 55V Max. over current Over-temperature, overload and short circuit protection

Note: parameter settings shall comply with the following rule, i.e. boost voltage > floating
Main Features charging voltage > over-discharge recovery voltage > over-discharge voltage.
• 12V/ 24 V system voltages are automatically recognized.
• An upgraded 3-stage PWM charging algorithm is adopted. Application of an equalizing charging to the battery periodically or when over
discharged, can effectively prevent the battery from non-equalization and sulfuration, thus extending the battery's service life.
• With temperature compensation employed, charging parameters can be automatically adjusted.
• A wide range of load working modes facilitate the product's application to different types of load.
• The product provides overcharge, over-discharge, overload protection, as well as short-circuit protection.
• By virtue of an advanced load starting method, large-capacitance loads can be started smoothly.
• The product provides a dot matrix graphic LCD screen and a human-machine interface with a key.
• The user-friendly design of browser and dynamic interfaces ensure convenient and intuitive operations.
• Boasting an industrial grade design, the product can function well in various tough conditions.
• TVS lighting protection is adopted.

T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com


SUNPAL POWER CO., LTD SOLAR CONTROLLER

Parameters
Parameters Value Remarks
Model HP2430N/2440N

Rated current 30A/40A

System voltage Automatic recognition of 12V/24V Default:


automatic
Manual setup identification

Rated power 12V/450W 24V/900W 12V/600W 24V/1200W


The higher the system
No-load loss < 22mA/12V;< 16mA/24V voltage, the lower the
no-load loss.

Max. Solar energy input voltage <55V

Max. voltageat the Battery type <34V

Parameters
battery end
Flooded FLD Sealed SLD GEL GEL Lithium LI Default SLD

Overvoltage protection 16.0V

Equalizing charging voltage 14.8 14.6 - -


HP2430/HP2440-N
Boost charging voltage 14.6 14.4 14.2 14.4
×1/12V;
Floating charging voltage 13.8 13.8 13.8 -
×2/24V;
Charging recovery voltage 13.2V

Over-discharge recovery voltage 12.5V(settable with the keys)

HP Series
Over-discharge voltage 11.0V(settable with the keys)

Equalizing charging interval 30 days - -

Equalizing charging time 1H - -


HP Series Smart Solar Charge Controller
Boost charging time 2H -

Temperature compensation -3.0mV/℃/2V -


HP2430N/HP2440N Light control voltage Light control on 5V, light control off 6 V (light control on plus 1 V)
×1/12V;
Light control judgment time ×2/24V;
10 minutes

Main Features USB function Yes

Bluetooth function optional


• Automatic system voltage identification
• Charging program options for sealed, GEL and flooded lead-acid batteries and lithium batteries are available. 232 Serial port communication function -25℃to+55℃;
• An upgraded 3-stage PWM charging algorithm is adopted. Application of an equalizing charge to the battery periodically or when over
Operating temperature optional
discharged can effectively prevent the battery from non-equalization and sulfuration, thus extending the battery's service life (with the
exception of GEL and lithium batteries). When temperature is above 60℃,charging function is turned
• With temperature compensation employed, charging parameters can be automatically adjusted (with the exception of lithium batteries). off, and the function is recovered when temperature is below 55℃;
Over temperature protection
When temperature is above 70℃,load starting function is turned
• A wide range of load working modes facilitate the product's application to different types of street lights and monitoring devices. off, and the function is recovered when temperature is below 60℃
• The product provides overcharge, over-discharge, overload protection, as well as short-circuit and reverse-connection protection.
• By virtue of an advanced load starting method, large-capacitance loads can be started smoothly. IP protection rating IP30
• A range of parameter settings and power-down saving functions are available, thus requiring no repeated setting. Net weight 700G
• The product provides a dot matrix graphic LCD screen and a human-machine interface with 2 keys. Battery plate reverse connection protection, a battery reverse
• The user-friendly design of browser and dynamic interfaces ensures convenient and intuitive operations. connection protection, charging battery board short circuit
Protection functions protection, charging the battery open circuit protection, charging
• (An optional communication function) provides a RJ12 data port (output of TTL232 level or bluetooth signals), with the data adopting the
over current protection, overload protection, load short-circuit
standard Modbus protocol, and can be used together with our upper computer monitoring software or mobile phone APP. protection controller and over temperature protection.
• Boasting an industrial grade design, the product can function well in various tough conditions.
Dimensions 166.0×118.2×52.6(mm)
• It features a backlit display, and the backlight will be turned on with a key pressed and turned off over a period of time.
• TVS lighting protection is adopted. Note: parameter settings shall comply with the following rule, i.e. boost voltage > floating
charging voltage > over-discharge recovery voltage > over-discharge voltage.

T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com


SUNPAL POWER CO., LTD SOLAR CONTROLLER

Parameters
Parameter Value
Model SR-LM10A

System voltage 12V/24V Auto

System current 10A

No-load loss <10mA/12V;10mA/24V

Solar energy input voltage <55V

Overvoltage protection 17.0V;×2/24V

Equal charging voltage 14.6V; ×2/24V(25℃), duration:1h

Ascending charging voltage 14.4V; 2/24V(25 , duration:2h

Float charging voltage 13.8V;×2/24V(25℃)

Return voltage during charging 13.2V;×2/24V(25℃)

Return voltage for over-discharging 12.5V;×2/24V

Undervoltage 12.0V;×2/24V

Over-discharging voltage 11.1V;×2/24V


LM10A
Temperature compensation -4.0mv/℃/2V;

Light-control voltage Light-control open 5V; light-control close 6V

Light-control judgment time 10min

LM Series
Working temperature -35℃ to +65℃;

Dimensions 124.7×69.4×34.0(mm)

Protection level IP30


LM series solar power intelligent PV controller Weight 106g

Over-charge, over-discharge, short circuit and over-load protection


Circuit protection
Anti- connection-reverse protection for solar battery and storage battery.

LM10A Notice1: If reverse connection of the storage battery, the controller would not be damage, but there is
the negative voltage output from the load will lead to the load damage.
LCD
Notice2: Time delay function when overload, the protection time is related to the ambient temperature.
Auto
INPUT
IP30 When overload, the overload protection will running auto. The first time is 5 seconds,the
PWM LCD DISPLAY LED DISPLAY
12V/24V 55V Max.
second time is 10 seconds, the third time is 15seconds, the fourth time is 30seconds and the
fifth time is 4hours or the second day it will recovery.
Main Features
• Automatic identification of 12V/24V system voltage.
• LED digital display and single key operations which makes operate simply and conveniently.
• Adopting ternary form charging algorithm, charge the storage battery in equalizing charge mode once a week .It can
prevent battery from imbalance and vulcanization effectively, also battery service life will be extended.
• Four working modes which made it convenient to use in all kinds of street lamps and monitoring devices.
• External temperature sensor can realize high-precision temperature compensation.
• Has the electricity protection data function .Parameter can be stored when the power system failure. No need to setting
again. It is very simple and convenient to use.
• Various status indications.
• Over charging protection, over discharging protection, over load, short circuit protection, reverse polarity protection
• TVS lightning protection.

T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com


SUNPAL POWER CO., LTD SOLAR CONTROLLER

RS232

Mobile phone&APP

System wiring diagram

BT-1

Accessories Series Bluetooth Adapter


RM-5 BT-1
• Realizes wireless monitoring and control function over the solarcharge controller

E4
• Supports cellphone APP, and boasts a plug and play feature andeasy setting
• Employs a dedicated Bluetooth chip with high performance andultra low power consumption
RJ45 LED DISPLAY Error Key • Adopts Bluetooth 4.0 and BLE technologies, boasting advantages ofquick communication, excellent anti-interference
capability, etc.
• Dispenses with external power source, being powered directlythrough the communication port
• Boasts a communication distance of up to 15 m
Main Features
• Adopts a 128*64 LCD screen, with the menus designed with numeric and graphic forms. Model
• With a graphical design, the main menu is artistic as well as informative: it can display up to 10 parameters and states. BT-1
• Able to read the historical data of a certain day.
Input voltage 5V-12V
• A low-power-consumption BLE4.0 feature enables more powerful functions when pairing with a mobile APP (optional).
• Employs two indicator lights to indicate controller abnormalities and communication errors respectively. Standby power consumption 0.04W
• Features a controller abnormality voice alarm function which can be switched on/ off.
• A backlight time setting function is available. Operating power consumption 0.05W
• Able to monitor live data and operating statuses of the controller .On/ off switching, clearing of historical data and
restoring to factory settings can all be done with this unit. Communication distance ≤15m
• Adoption of standard Modbus communication protocol.
Serial baud rate Fixed baud rate 9600bps
Parameters Communication mode RS232

Parameter Value Port type RJ12


LCD backlight on <35mA/12V
Static power consumption Standard network cable
LCD backlight off <25mA/12V Connection cable (parallel cable)

Baud rate RS232 66*51*15.5mm


Dimensions
Communication port 9600bps
Installation dimensions 57.5, φ3.2mm
Operating temperature -35℃ to +65℃;
Operating temperature -20°C to 75°C
Product weight 0.5kg
Protection degree IP67
Dimensions 115.82×115.82 (mm) (L×W)
Net weight 120g

T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com


SUNPAL POWER CO., LTD SOLAR CONTROLLER

Parameters
Adjustable
Parameter Value Default
or not
Model SR- D M120 SR- D M160

No-load loss 26mA/12V; 15mA/24V 28mA/12V; 17mA/24V

System voltage 12V/24V

Charging current 10A 15A

Max. solar panel power 130W/12V;260W/24V 200W/12V;400W/24V

Solar panel input voltage <60V

MPPT tracking efficiency >99%


Charging conversion
efficiency 90% ~ 96%
Load conversion
efficiency 90% ~ 96%

Output current 70mA~4200mA 70mA~5600mA √ 900mA

Load current accuracy ±3% (load current > 300 mA)

Max. load power 60W/12V;120W/24V 80W/12V;160W/24V


DM120 DM160 Load output voltage <60V
Over-voltage protection 17.0V; × 2/24V

Charging voltage limit 15.5V; × 2/24V

Lead-acid batteries
Equalizing charging voltage (Boost charging voltage+0.2V; ×2/24 V (25 °C)
LITHIUM BATTERY

14.6V
SOLAR CHARGE CONTROLLER
WITH STEP-UP LED DRIVER

Equalizing charging time 1 hour

MPPT Integrated Constant-Current Equalizing charging interval 30 days

Charge Controller for Solar Street Lights Boost charging voltage 7.5V~15.5V;×2/24V(25℃) √ 14.4V
Boost charging time 4 hours

Floating charging voltage √


DM120/DM160
7.5V~15.5V;×2/24V(25℃) 13.8V
Temperature
-3.0mV/℃/2V
compensation factor
Over-voltage protection (over charge voltage+2V);×2/24V(25℃) √ 16.6V
Whether charging is

batteries
Yes, No √ No

Lithium
prohibited below 0 °C
MPPT
Overcharge voltage 7.5V~15.5V;×2/24V(25℃) √ 14.6V
Main Features Overcharge recovery
voltage 7.5V~15.5V;×2/24V(25℃) √ 13.6V
• Features true MPPT functions, applicable to monocrystalline, polycrystalline and amorphous silicon solar panels serially connected in various
Over-discharge voltage 7.5V~15.5V;×2/24V(25℃) √ 11.0V
numbers, significantly improving the solar panels' energy utilization ratio.
• MPPT solar charging technology , the maximum solar input voltage Voc ≤ 60V . Over-discharge recovery
voltage 7.5V~15.5V;×2/24V(25℃) √ 12.6V
• The load is stepping up and constant current output which can support maximum 18pcs of LED beads connected in series • Adopts an
improved charging algorithm that supports 12 V and 24 V lead-acid batteries and lithium batteries, and the user can set the operating modes Light control voltage 5V~15V;×2/24V √ 10V
for lead-acid batteries or lithium batteries accordingly.
Light control delay 1~50min √ 1min
• Boasts a load triple-stage brightness adjustment and morning on design, with an operating duration adjustable from 0 to 15 hours and a
power settable from 0 to 100%. Operating temperature -35℃ ~ +65℃
• Features a system status log function, able to record a maximum of 7 days of system status, comprehensively and effectively monitoring the
system's conditions. Protection degree IP68
• Data communication adopts a multi-time two-way handshake protocol and a data compression algorithm, realizing precise and fast data Weight(g) 380 480
transmission.
• Features an intelligent power mode which can extend the battery life to its top limit by adjusting the load power automatically according to the Dimensions (mm) 114x88.3x24.5mm 142x88.3x24.5mm
remaining battery capacity.
• True constant current rather than current-limiting control ensures smooth and stable output current, effectively reducing LED light attenuation Note: parameter settings shall comply with the following rule, i.e. boost voltage > floating
and extending LED service life. charging voltage > over-discharge recovery voltage > over-discharge voltage.
• With an infrared remote control function, operations including setting parameters, reading status and viewing historical data can be conducted.
• A metal case and an IP68 waterproof level enable the device to operate in various kinds of tough conditions.
• An overheat protection function enables the device to scale down the load or shut off the load completely when its temperature exceeds a
certain point.
• A range of protection measures such as battery reverse-connection protection, LED short-circuit and open-circuit protection, etc., put the
system under comprehensive and constant guard.harging current and voltage, load operating status, controller operating status and other data,
and automatically triggers alarms when failures are detected.

T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com T: 0086-551-65865992 E: info@sunpalpower.com W: www.sunpalpower.com

You might also like