Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

DENSITY DENSITY DIFFEREN

TEMPERATURE OF FUEL OF CE IN Viscosity, Temp vs Density Chart


S/N Characteristic EHT Remarks Remarks
(℃) OIL WATER DENSITY (Cst) 120
(kg/m3) (kg/m3) (kg/m3)

1 15 991 999 8 5100


100
2 30 982 995 13 1200 Pour Point

3 32 981 995 14 1150


EHT can be configured at 40℃ to 80
4 40 976 992 16 710
50℃

5 45 973 990 17 520

6 50 970 988 18 380 60

7 52 969 987 18

8 54 968 987 19 Extrapolated


40

9 56 966 986 20 Extrapolated

10 58 965 986 20 Extrapolated


20
11 60 964 985 21 Flash Point Extrapolated

12 62 963 984 21 Extrapolated

13 64 962 984 22 Extrapolated 0


930 940 950 960 970 980 990 1000 1010

14 66 961 983 23 Extrapolated


DENSITY OF FUEL OIL (kg/m3) DENSITY OF WATER (kg/m3)

15 68 959 982 23 Extrapolated

16 70 958 982 24 Extrapolated

17 72 957 981 24 Extrapolated Pour @ 30 Deg C

18 74 956 980 25 Extrapolated Flash @ 60 Deg C

19 76 955 980 25 Extrapolated

20 78 953 979 26 Extrapolated

21 80 952 978 26 Extrapolated

22 82 951 978 27 Extrapolated

23 84 950 977 27 Extrapolated

24 86 949 976 28 Extrapolated

25 88 947 976 28 Extrapolated

26 90 946 975 29 Extrapolated

27 92 945 975 30 Extrapolated

28 94 944 974 30 Extrapolated

29 96 943 973 31 Extrapolated

30 98 941 973 31 Extrapolated

31 100 940 972 32 Extrapolated

You might also like