Table of Contens
1 On Board Display........................................................................................ 3
1.1 Display 1, Description: ............................................................................................... 3
1.2 Display 2, Description: ............................................................................................... 4
1.3 Examples : .................................................................................................................. 4
Part: 4 - AA 3
OTIS Field Component Manual No.: JAA26801AAFIVc
European and Transcontinental
Vintage: 02 / 1
Operations
Service Tool Manual Page: 3/5
Product MCS - LMCSS Date: 06-May-1998
Administration On Bord Display
1 On Board Display
The on Board Display provides two different displays with a length of 4 characters.
If the car is not moving the two displays will alternate every 2 seconds.
In case of elevator is in shut down mode and blocked, the level accuracy display will
change to "****"
- error code : 0 - 99
first event / error of the last run in case of no error display shows " ".
For the complete table of event codes refer to the Service Tool Manual - Reference List
of the Field Component Manual.
Stop distance from the middle of the non relevelling zone in [mm].
Values are displayed hexadecimal.
If the distance exceeds +15 or -15 [mm] the display will show: -- or ++
Shown is only the position in relation to the magnet switches not to the floor level!
**** indicates that an unsafe situation exists or an error has exceeded the maximum
number of retries and forced the system to block any further movement.
1.3 Examples :
1: car standing at floor 7 without error
2-07 <------alternating------> +1
level accuracy = +1 mm
no error
floor number = 7
moving direction = not moving
motion logic state = stand by
Part: 4 - AA 3
OTIS Field Component Manual No.: JAA26801AAFIVc
European and Transcontinental
Vintage: 02 / 1
Operations
Service Tool Manual Page: 5/5
Product MCS - LMCSS Date: 06-May-1998
Administration On Bord Display
7d04
floor number = 4
moving direction = down
motion logic state = normal run
elevator is blocked
error 2703 = DBSS drive fault
floor number = 7
moving direction = not moving