Part: 4 - AA 3

OTIS Field Component Manual No.: JAA26801AAFIVc


European and Transcontinental
Vintage: 02 / 1
Operations
Service Tool Manual Page: 1/5
Product MCS - LMCSS Date: 06-May-1998
Administration On Bord Display

MCS - LMCSS
On Board Display

Authorisation Date : 06 May 1998

Running on PCB : JBA26801AAF or higher

Software Version : GBA30085IAA

Date Author Page Comments


MAY - 98 F. Kunze FOD Berlin 1-5 replace

Copyright 1998, OTIS GmbH Berlin


No part of this manual may be copied or reproduced in any form or by any means without the prior written consent of OTIS GmbH.
Part: 4 - AA 3
OTIS Field Component Manual No.: JAA26801AAFIVc
European and Transcontinental
Vintage: 02 / 1
Operations
Service Tool Manual Page: 2/5
Product MCS - LMCSS Date: 06-May-1998
Administration On Bord Display

Table of Contens

1 On Board Display........................................................................................ 3
1.1 Display 1, Description: ............................................................................................... 3
1.2 Display 2, Description: ............................................................................................... 4
1.3 Examples : .................................................................................................................. 4
Part: 4 - AA 3
OTIS Field Component Manual No.: JAA26801AAFIVc
European and Transcontinental
Vintage: 02 / 1
Operations
Service Tool Manual Page: 3/5
Product MCS - LMCSS Date: 06-May-1998
Administration On Bord Display

1 On Board Display
The on Board Display provides two different displays with a length of 4 characters.

If the car is not moving the two displays will alternate every 2 seconds.

During running only the first display will be shown.

In case of elevator is in shut down mode and blocked, the level accuracy display will
change to "****"

display 1 : - motion logic state ( 1 char. )


- run direction ( 1 char. )
- floor number ( 2 char. )

display 2 : - level accuracy ( 2 char. )


- system is shutdown and blocked ( 4 char. )

For more detailed information use the SERVICETOOL menus:

- <M><2<>1<>1> MONITOR, STATUS and


- <M<>2<>2<>2> TEST, EVEVT LOGGING

1.1 Display 1, Description:

- motion logic state : 0 - A - run direction : u, d, -

0 shut down u up direction


1 motor generator stop d down direction
2 stand by - no direction
3 inspection stop
4 inspection run
5 learn stop - floor number : 0 - 99
6 learn run -- invalid floor number
7 normal run
8 relevelling run
9 reinitialization run
A recover run
Part: 4 - AA 3
OTIS Field Component Manual No.: JAA26801AAFIVc
European and Transcontinental
Vintage: 02 / 1
Operations
Service Tool Manual Page: 4/5
Product MCS - LMCSS Date: 06-May-1998
Administration On Bord Display

1.2 Display 2, Description:

- error code : 0 - 99
first event / error of the last run in case of no error display shows " ".

For the complete table of event codes refer to the Service Tool Manual - Reference List
of the Field Component Manual.

note: code 2103 is displayed as 13


codes 2810 to 2819 are displayed as 90 to 99

- Level Accuracy : +15 to -15 [mm]

Stop distance from the middle of the non relevelling zone in [mm].
Values are displayed hexadecimal.
If the distance exceeds +15 or -15 [mm] the display will show: -- or ++

Shown is only the position in relation to the magnet switches not to the floor level!

- System is shutdown and blocked:

**** indicates that an unsafe situation exists or an error has exceeded the maximum
number of retries and forced the system to block any further movement.

A RESET of the LMCSS is required to clear the blocking mode!

To see the reason of the shutdown use Service Tool menu:

<M><2<>2<>2>: TEST, EVEVT LOGGING

1.3 Examples :
1: car standing at floor 7 without error

2-07 <------alternating------> +1

level accuracy = +1 mm
no error
floor number = 7
moving direction = not moving
motion logic state = stand by
Part: 4 - AA 3
OTIS Field Component Manual No.: JAA26801AAFIVc
European and Transcontinental
Vintage: 02 / 1
Operations
Service Tool Manual Page: 5/5
Product MCS - LMCSS Date: 06-May-1998
Administration On Bord Display

2: car moving down at floor 4

7d04

floor number = 4
moving direction = down
motion logic state = normal run

3: car is blocked and in shutdown mode


( system reset is necessary to start new run )

0-07 <------alternating------> 73**

elevator is blocked
error 2703 = DBSS drive fault
floor number = 7
moving direction = not moving
motion logic state = shut down