B 8453 b162 Assembly Model

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

MATERIAL LIST FOR ONE BEAM MK'D B-8453-B162

TOTAL QTY REQUIRED : 1 No(s)


1773 86
MARK DESCRIPTION QTY MATERIAL LENGTH WGT T. WT. (KG)
1510 67 283 1 ASTM A992 1860 69.1 69.1
P098 UB254*146*37
P113 FLT10*70 1 ASTM A36/*** 234 1.3 1.3
P116 PL10*347 1 ASTM A36/*** 495 7.9 7.9
P227 FLT10*120 2 ASTM A36/*** 150 1.4 2.8
P369 PL10*210 1 ASTM A36/*** 234 3.6 3.6
P378 PL10*348 1 ASTM A36/*** 602 12.2 12.2
TOTAL WEIGHT FOR ONE ASSEMBLY 96.9
P378 BOLT LIST ONE ASSEMBLY B-8453-B162
SITE/SHOP BOLT DESCRIPTION QTY/ONE QTY/ALL GRADE FINISH
P369 Site M 16 x 40 4 4 A325M/A563 Nuts Galvanized
Site M 20 x 45 3 3 A325M/A563 Nuts Galvanized
Site M 24 x 55 3 3 A325M/A563 Nuts Galvanized

P098 P116

P227 P227 P113


245 1000 615

-
173
P098
40 1734 86 P113
3 ø 22 P227 1) SURFACE PREPARATION FOR GALVANIZATION:
UB254*146*37 x 1860 7 118 SANDBLASTING SA21/2.
P113

53
2) GALVANIZATION: ASTM A123/A123M

75

200
P098 P227
P378

46
3) WELDING WHERE NOT INDICATED SHALL BE CONTINUOUS
P098 P369

75
A A B
3 ø 22 P113 2 ø 18 FILLET WELD. DIMENSION "S" OF NON-DIMENSIONED FILLET

60
T1
P378 WELDS SHALL AT LEAST BE EQUAL TO:
53

S = 0.80 * T for Fy <= 250 MPa


P369
75

P378 P369 S = 1.00 * T for 250 < Fy <= 350 MPa T2

P227 P227 Where: S


75

P116
46

394
T = MIN (T1, T2) Fy = STEEL YIELD STRENGTH OF THE
ELEMENTS TO BE CONNECTED.

P116 4) THE MINIMUM FILLET WELD SIZE TO BE USED FOR


STRUCTURAL WELDS IS 5mm.

5) A MINIMUM SEAL WELD LEG SIZE OF 3mm FILLET WELDS

106
3 SHALL BE USED.
A B - B 6) ALL STRUCTURAL STEEL, INCLUDING PLATFORMS,
A - A
A HANDRAILS , LADDERS, CAGES, STAIR TREADS, CHEQUERED
B PLATES & GRATINGS SHALL BE HOT DIP GALVANIZED ONLY,
P116 EXCEPT CRANES, LIFTING BEAMS, MONORAILS, DAVITS WHICH
1308 491 60
ARE GALVANIZED AND PAINTED RAL 1004 SAFETY YELLOW.
- FOR DETAILS REFER TO PROJECT SPECIFICATION 14.192.028”

3 ø 26 3 ø 26

P369
SD-UJV
10

10
DOCUMENT STATUS SIGNED DATE
10

P116 P227 P113 P378 1 - ACCEPTED AS SUBMITTED (submit certified as final)

- -
10

10
REVISE AND RESUBMIT
- 2 -
INCORPORATE COMMENTS, UP-REV AND RESUBMIT
147 446 156 REJECTED - Document unacceptable, REVise and resubmit
42 75 75 42 3 -
- - (work can proceed where not impacted by this rejection)

12 12 4 - REVIEW NOT REQUIRED


35 115 234
3 ø 22 75
147

150 75 SCF - SUPPLIER CERTIFIED AS FINAL

223
P227
347

140

140

348
70 ISSUE OF CERTIFIED FINAL DOCUMENT DOES NOT RELIUPES SUPPLIER OF
210

RESPONSIBILITY OR LIABILITY UNDER THE CONTRACT/PURCHASE ORDER


170
60
200

85 67
P378
70

70
120

125
100

P113
- CWP No:A10-WP5.4-020-FI-MC-101
30

15

P369 12
P116 3 ø 26 12 3 ø 26
495 15 63 602
2 ø 18
234
295 75 75 50 -
76 134 392
-
- -
1860 OB RE-ISSUED FOR REVIEW UP 30/06/23 ET 30/06/23 EA 30/06/23
40 1820
OA RE-ISSUED FOR REVIEW UP 01/03/23 ET 01/03/23 EA 01/03/23
O ISSUED FOR REVIEW UP 02/02/23 ET 02/02/23 EA 02/02/23
3 ø 22 REV DESCRIPTION DWN DATE CHKD DATE APPD DATE
REVISIONS
53

This Document is confidential. The copyright therein is vested in Nigeria LNG Ltd, Nigeria.
75

P098 Recipient must obtain the written authority of the said company before wholly or partially duplicating.
All rights reserved.
75

PO No: 1423030
VENDOR DRAWING. No. NIGERIA LIQUEFIED NATURAL GAS
TGIL-AD-19589-310 NLNG - BONNY
- DRAWN: UP PROJECT
DATE: 30/06/23 NLNG TRAIN 7
CHECKED: ET
VENDOR NAME
DATE: 30/06/23
THOMPSON & GRACE INVESTMENTS LTD.
APPROVED: EA
LOCATION DISCIPLINE UNIT No
DATE: 30/06/23
BONNY ISLAND, NIGERIA CIV 2000
APPD. LNG:
TITLE
DATE: PO 1423030 Thompson & Grace: ASSEMBLY DRAWING
CONTRACTOR DRAWING. No.
1 No.BEAM REQUIRED AS DRAWN MARKED B-8453-B162 {QRCODE}
L020-CD-B-19589 FOR STEEL STRUCTURE FOR B-8453
Tekla structures

SCALE COMPANY PROJECT No. COMPANY DRAWING No. SHEET REV


B190170NTP
CAD REF: T-14.419.589-SHT160.dwg ORIGINAL SIZE: A1 CLASSIFICATION: MOST CONFIDENTIAL CONFIDENTIAL RESTRICTED UNRESTRICTED 1:10 CONTRACTOR PROJECT No.
N88480 T-14.419.589 160 OF 468 OB

You might also like