Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PGC1000. The most effective


solution for monitoring
HRVOCs in flare gas.

To achieve federally mandated Ozone requirements in Houston-Galveston area, the Texas


Commission on Environmental Quality has required the monitoring of HRVOC emissions from flares.
ABB’s PGC1000 is the most cost-effective solution for monitoring HRVOCs in flare gas. The PGC1000
offers low installation cost, low utility requirements, low maintenance and unmatched performance.

Scan the QR code for more information.


abb.com/upstream

PGC1000
The most effective solution
for monitoring HRVOCs in
flare gas.

Low installation cost Unmatched performance


As with any large analyzer project, typically the analyzers Low maintenance and installation costs are fine,
only make up 20-40% of the total cost of the project. but who wants to give up precision and accuracy
The rest of the cost is eaten up by environmental when dealing with regulatory agencies. With the
shelters, sample transport lines, etc. This can be PGC1000 you don’t have to. The PGC1000 utilizes
magnified with HRVOC applications because typically the same hardware as the NGC 8206. The analyzer
flares are located in a remote area of the plant. which set a new standard for natural gas custody
transfer measurement. As with the NGC 8206, the
The PGC1000 drastically reduces installation costs. PGC1000 offers:
First, it does not require an environmental shelter. • Unmatched Valve Performance – The GC valve
Secondly, being a Class1, Div 1 device, it can be contains no metal moving parts, this equates
located much closer to the sample point, eliminating to millions of cycles in between failures.
the need for long, expensive sample runs. • Unmatched Detector Performance – ABB sets the
standard in TCD performance, in terms of both
Low utility requirements noise and sensitivity. ABB hold several patents on
The PGC1000 does not require instrument air. The our detector technology and more are pending.
only utility gas required, is the carrier gas, Helium.
Typical consumption for the HRVOC application is 6
months per bottle.

Low maintenance
When dealing with regulatory agencies reporting
requirements, downtime is critical. The PGC1000
utilizes a modular, field proven, design.

All replaceable parts are available as easy to replace


modules. All analytical modules are fully tested and
characterized at the factory. Setup has become as
easy as clicking a mouse. With the modular design
of the PGC1000 downtime has been reduced to hours
SS/2102756-EN – Rev. AF 04.2017

instead of days.


ABB Upstream Oil & Gas
7051 Industrial Boulevard
Bartlesville, Oklahoma 74006
totalflow.inquiry@us.abb.com
+1 918 338 4888 —
© Copyright 2017 ABB. All rights reserved.
abb.com/upstream Specifications subject to change without notice.

You might also like