Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Door Schedule

Mark Type Mark Count Family and Type Height

37' - 11 1/2"
1 4 1 Single-Flush: 30" x 84" 7' - 0"
15' - 3" 2 9 1 Closet - Bifold Door - 2 Panel: 30" x 84" 7' - 0"
3 9 1 Closet - Bifold Door - 2 Panel: 30" x 84" 7' - 0"
2' - 9"
4 4 1 Single-Flush: 30" x 84" 7' - 0"
4' - 0" 2' - 9" 2' - 6" 4' - 3"
5 4 1 Single-Flush: 30" x 84" 7' - 0"
1 1
9
1 1
Room Legend 6
7
9
9
1
1
Closet - Bifold Door - 2 Panel: 30" x 84"
Closet - Bifold Door - 2 Panel: 30" x 84"
7' - 0"
7' - 0"
9 1 1 Single-Flush: 36" x 84" 7' - 0"
2' - 6"

1
Bath 10 9 1 Closet - Bifold Door - 2 Panel: 30" x 84" 7' - 0"
www.mrvasiloff.org

5' - 0"
2 11 9 1 Closet - Bifold Door - 2 Panel: 30" x 84" 7' - 0"

Bedroom 1 Kitchen Dining


Bedroom 1 12 1 1 Single-Flush: 36" x 84" 7' - 0"
Grand total: 11
10' - 9"

4 5 6
Bedroom 2
GENERAL NOTES
1. STANDARD DETAILS THAT ARE PROVIDED WITH
3 Dining THESE PLANS ARE
2' - 6"

Kitchen Room Schedule PROVIDED TO ILLUSTRATE A SPECIFIC DETAIL

4' - 6"
22' - 0"

1 10

1 Living
Number Name Area OR CONSTRUCTION
4
11
1 Bedroom 2 114 SF CONCEPT. THEY WERE NOT DRAWN

3' - 0"
2 Bath 40 SF
SPECIFICALLY FOR THIS PROJECT AND

4' - 6"
3 Living 150 SF
Bedroom 2 5
Living
1
4
5
Bedroom 1
Kitchen
146 SF
78 SF
MAYSHOW BACKGROUND DETAILS THAT ARE
1 3
Bath
6 Dining 150 SF NOT IDENTICAL TO THIS PROJECT.
5' - 6"

6 2 7
Grand total: 6
2. WHERE A DISCREPANCY EXISTS BETWEEN

5' - 1"
12
THE PLANS, DETAILS,
1 1 SCHEDULES, TABLES AND/OR SPECIFICATIONS,
2' - 6" 3' - 9"

Window Schedule
THE MOST STRINGENT
Mark Type Mark Count Family and Type Height
REQUIREMENT SHALL APPLY. ALL SUCH
11' - 6" 2' - 6" 8' - 0" 2' - 6"
DISCREPANCIES SHALL BE
1 1 1 Fixed: 36" x 48" 4' - 0"
2 1 1 Fixed: 36" x 48" 4' - 0" REPORTED TO THE ENGINEER PRIOR TO
1
Level 1
3
4
1
1
1
1
Fixed: 36" x 48"
Fixed: 36" x 48"
4' - 0"
4' - 0"
PROCEEDING WITH THE WORK.
1/4" = 1'-0"
5 1 1 Fixed: 36" x 48" 4' - 0" 3. ALL WORK SHALL COMPLY WITH THE CURRENT
7 1 1 Fixed: 36" x 48" 4' - 0"
8 1 1 Fixed: 36" x 48" 4' - 0" BUILDING CODE AND ALL
10
11
1
1
1
1
Fixed: 36" x 48"
Fixed: 36" x 48"
4' - 0"
4' - 0"
GOVERNING STANDARDS & REGULATIONS.
12 3 1 Fixed: 24" x 24" 2' - 0" 4. CHECK ALL DIMENSIONS SHOWN ON THE
13 3 1 Fixed: 24" x 24" 2' - 0"
Grand total: 11
STRUCTURAL DRAWINGS WITH
MECHANICAL, ELECTRICAL, AND/OR ANY OTHER
RELATED DRAWINGS
AND REPORT ANY INCONSISTENCIES TO THE
ENGINEER BEFORE PROCEEDING WITH ANY
WORK.
5. READ STRUCTURAL DRAWINGS IN
CONJUNCTION WITH ALL OTHER
CONTRACT DOCUMENTS.
6. SEE MECHANICAL, AND ELECTRICAL
DRAWINGS FOR LOCATIONS OF
OPENINGS, PITS, BASES, SUMPS,TRENCHES,
SLEEVES, DEPRESSIONS,
GROOVES AND CHAMFERS NOT INDICATED ON
THE STRUCTURALDRAWINGS.
7. CLARIFY WITH THE ENGINEER ANY QUERIES
REGARDING
2
South
1/4" = 1'-0"
INTERPRETATION OF THE DRAWINGS BEFORE
PROCEEDING WITH ANY WORK.
8. THE CONTRACTOR SHALL VERIFY AND BE
RESPONSIBLE FOR ALL
DIMENSIONS AND SHALL REPORT ANY
DISCREPANCY TO THE ENGINEER
BEFORE PROCEEDING WITH ANY WORK.

Koe Lanker
Floorplan 2
Unnamed
Project Number Project Number
Date Issue Date
Drawn By Author
Checker

A101
Checked By

Scale 1/4" = 1'-0"

You might also like