C-FIX Online 1.1.58.

1
Database version 1.1.60.0
Date 10/04/2024

Deutschland
fis che r fixings UK Ltd
Whitely Road; Hithercroft Industrial Estate
Wallingford; Oxfordshire; OX10 9AT
technical@fischer.co.uk

Design specifications
Anchor
Anchor system fischer injection system FIS EM Plus with threaded rod
FIS A or RG M
Injection resin FIS EM Plus 390 S
Fixing element FIS A M 20 x 245 8.8,
gvz 8.8
Anchorage depth 150 mm
Design data ETA-17/0979 (17.06.2020)

Units of Measurement
Geometry mm
Design action values kN, kNm

Not draw n to s cale

The input values and the design results should be checked against local valid standards and approvals.
Please respect the disclaimer of warranty in the license agreement of the Software.

Page 1
C-FIX Online 1.1.58.1
Database version 1.1.60.0
Date 10/04/2024

Input Data
Design method EN 1992-4:2018
Base material Normal weight concrete, C40/50, EN 206:2013
Concrete condition Cracked, Dry hole
Temperature range 24 °C Long term temperature, 40 °C Short term
temperature
Reinforcement No or standard reinforcement, No edge reinforcement,
With reinforcement to control splitting
Drilling method Hammer drilling
Installation type Push-through installation
Annular gap Filled
Type of loading Static or quasi-static
Working life 50 years
Ratio between sustained 0.0
load and total load
Base plate location Base plate flush installed on base material
Base plate geometry 200 mm x 200 mm x 25 mm
Profile type None

Design actions incl. partial safety factor of the load


Case NEd VEd,x VEd,y MEd,x MEd,y MEd,z Type of loading Name
kN kN kN kNm kNm kNm
1 15.00 0.00 0.00 0.00 0.00 0.00 Static or quasi-static

Resulting anchor forces


Anchor no. Tensile action Shear action Shear action x Shear action y
kN kN kN kN
1 15.00 0.00 0.00 0.00

Max. concrete compressive strain 0.00 ‰


Max. concrete compressive stress 0.00 N/mm²
Resulting tensile actions 15.00 kN, X/Y position (0 / 0 mm)
Resulting compression actions 0.00 kN, X/Y position (0 / 0 mm)

Resistance to tension loads


Proof Action Capacity Utilisation βN
kN kN %
Steel failure * 15.00 130.67 11.5
Combined failure 15.00 24.84 60.4
Concrete cone failure 15.00 25.93 57.9
* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals.
Please respect the disclaimer of warranty in the license agreement of the Software.

Page 2
C-FIX Online 1.1.58.1
Database version 1.1.60.0
Date 10/04/2024

Steel failure
NRk,s
NEd ≤ NRd,s = γMs
NRk,s γMs NRd,s NEd βN,s
kN kN kN %
196.00 1.50 130.67 15.00 11.5

Anchor no. βN,s Group N° Decisive β


%
1 11.5 1 βN,s;1

Combined failure
NRk,p
NEd ≤ NRd,p = γMp
Ap,N (7.13)
0
NRk,p = NRk,p ∙ 0 ∙ ψs,Np ∙ ψg,Np ∙ ψec,Np ∙ ψre,Np
Ap,N
2
NRk,p = 85.72 k N ∙ 105625 mm2 ∙ 0.833 ∙ 1.000 ∙ 1.000 ∙ 1.000 = 37.26 k N
202500 mm
0
NRk,p = ψsus ∙ π ∙ d ∙ hef ∙ ψc ∙ τRk = 1.000 ∙ π ∙ 20 mm ∙ 150 mm ∙ 1.07 ∙ 8.50 N / mm2 = 85.72 k N (7.14)

ψsus = 1.000
αsus = 0.000 ≤ ψ0sus = 0.600
scr,Np = min 7.3 ∙ d ∙ (ψsus ∙ τRk,ucr )0.5; 3 ∙ hef (7.15)

scr,Np = min 7.3 ∙ 20 mm ∙ (1.000 ∙ 16.00 N / mm2)0.5; 3 ∙ 150 mm = 450 mm


scr,Np (7.16)
ccr,Np = = 450 mm = 225 mm
2 2
= min 1; 0.7 + 0.3 ∙ c c = min 1; 0.7 + 0.3 ∙ 100 mm
(7.20)
ψs,Np = 0.833 ≤ 1
cr,Np 225 mm

ψg,Np = ψ0g,Np − s 0 0 mm ∙ (1.000 − 1) = 1.000 ≥ 1 (7.17)


scr,Np ∙ (ψg,Np − 1) = 1.000 − 450 mm
ψc ∙ τRk 1.5 (7.18)
ψ0g,Np = √ n − ( √ n − 1) ∙ τRk,c
2 1.5
ψ0g,Np = √ 1 − ( √ 1 − 1) ∙ 1.07 ∙ 8.50 N / mm
2 = 1.000 ≥ 1
9.49 N / mm
k3 7.7
(7.19)
τRk,c = ∙ hef ∙ fck = ∙ 150 mm ∙ 40.00 N / mm2 = 9.49 N / mm2
π∙d π ∙ 20 mm

ψec,Np = 1 ⇒ ψec,Npx ∙ ψec,Npy = 1.000 ∙ 1.000 = 1.000 ≤ 1


(7.21)
2 ∙ eN
1+ s
cr,Np

ψec,Npx = 1 = 1.000 ≤ 1 ψec,Npy = 1 = 1.000 ≤ 1


1 + 0 mm
2 ∙ 1 + 0 mm
2 ∙
450 mm 450 mm
ψre,Np = 1.000 (7.5)

The input values and the design results should be checked against local valid standards and approvals.
Please respect the disclaimer of warranty in the license agreement of the Software.

Page 3
C-FIX Online 1.1.58.1
Database version 1.1.60.0
Date 10/04/2024

NRk,p γMp NRd,p NEd βN,p


kN kN kN %
37.26 1.50 24.84 15.00 60.4

Concrete cone failure


NRk,c
NEd ≤ NRd,c = γMc
Ac,N (7.1)
0
NRk,c = NRk,c ∙ 0 ∙ ψs,N ∙ ψre,N ∙ ψec,N ∙ ψM,N
Ac,N
2
NRk,c = 89.47 k N ∙ 105625 mm2 ∙ 0.833 ∙ 1.000 ∙ 1.000 ∙ 1.000 = 38.89 k N
202500 mm
0 (7.2)
NRk,c = k1 ∙ fck ∙ hef1.5 = 7.7 ∙ 40.00 N / mm2 ∙ (150 mm)1.5 = 89.47 k N

A0c,N = scr,N ∙ scr,N = 450 mm ∙ 450 mm = 202500 mm2 (7.3)

ψs,N = min 1; 0.7 + 0.3 ∙ c c = min 1; 0.7 + 0.3 ∙ 100 mm


(7.4)
= 0.833 ≤ 1
cr,N 225 mm
ψre,N = 1.000 (7.5)

ψec,N = 1 ⇒ ψec,Nx ∙ ψec,Ny = 1.000 ∙ 1.000 = 1.000 ≤ 1


(7.6)
2 ∙ eN
1+ s
cr,N

ψec,Nx = 1 = 1.000 ≤ 1 ψec,Ny = 1 = 1.000 ≤ 1


1 + 0 mm
2 ∙ 1 + 0 mm
2 ∙
450 mm 450 mm
ψM,N = 1.000 (7.7)

NRk,c γMc NRd,c NEd βN,c


kN kN kN %
38.89 1.50 25.93 15.00 57.9

Utilization to tensile and shear loads, as well as interaction

Decisive utilisation for tensile loads βN = 60.39 %

Proof successful

Technical remarks
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state
and the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of
the actions introduced by the anchors. For these verifications the additional provisions given in the current design method
shall be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate must be
sufficiently stiff. C-FIX offers a special module to determine a sufficient base plate stiffness. Utilisation is recommended.

The input values and the design results should be checked against local valid standards and approvals.
Please respect the disclaimer of warranty in the license agreement of the Software.

Page 4
C-FIX Online 1.1.58.1
Database version 1.1.60.0
Date 10/04/2024

Legal provisions
All information and data contained in the programs refer exclusively to the Use of fischer products and based on the
principles, formulas and safety regulations in accordance with the technical instructions and fischer''s operating, setting
and assembly instructions etc., which must be strictly observed by the user. All values contained are average values;
therefore, application-specific tests must always be carried out before using the respective fischer product. The results of
the calculations carried out using the software are based mainly on the data you enter. You therefore bear sole
responsibility for the accuracy, completeness and relevance of the data you enter. You are still solely responsible for
checking the results of the calculation to have it checked and approved by a specialist before use for your specific system
(s), especially with regard to conformity with applicable standards and approvals. The dimensioning program serves
merely as an aid for the interpretation of standards and approvals without any guarantee of accuracy, correctness and
relevance of results or suitability for a particular application. The user must take all necessary and reasonable measures
to prevent damage caused by the to prevent or limit the design program. In particular, for regular backups, you must of
programs and data as well as regular updates of the software offered by fischer, if necessary. Carry out design program.
Unless you use the automatic update function of the software, you have to m'+'ake sure by manual updates via the fischer
website that you always have the current and therefore use a valid version of the design program. Insofar as you culpably
breach this obligation if the goods are damaged, fischer is not liable for the consequences, in particular not for the
replacement of the goods lost or damaged data or programs.

The input values and the design results should be checked against local valid standards and approvals.
Please respect the disclaimer of warranty in the license agreement of the Software.

Page 5
C-FIX Online 1.1.58.1
Database version 1.1.60.0
Date 10/04/2024

Installation data
Anchor
Anchor system fischer injection system FIS EM Plus with threaded rod
FIS A or RG M
Injection resin FIS EM Plus 390 S Art.-No. 544155
Fixing element FIS A M 20 x 245 8.8, Art.-No. 519404
gvz 8.8
Accessories Dispenser FIS DB S Pro UK Art.-No. 564960
Compressed-air cleaning tool Art.-No. 093286
Compressed air (oil-free), min. 6 By job site
bar
Cleaning brush BSB Ø25 Art.-No. 001495
SDS socket with internal thread M8 Art.-No. 530332
Hammer drill Quattric II 24/200/250 Art.-No. 549962
Hollow drill FHD Max 24/400/620 Art.-No. 546604
Alternative injection resin FIS EM Plus 585 S Art.-No. 544165
FIS EM Plus 585 S Art.-No. 544165
FIS EM Plus 1500 S Art.-No. 544173
FIS EM Plus 1500 S Art.-No. 544173

Installation details
Size M20
Drill hole diameter d0 = 24 mm
Drill hole depth h2 = 175 mm
Anchorage depth hef = 150 mm
Drilling method Hammer drilling
Drill hole cleaning 2 times blowing with compressed air,
2 times brushing,
2 times blowing with compressed air
When using a hollow drill (e.g. FHD), no cleaning is
necessary.
Installation type Push-through installation
Annular gap Filled
Installation torque Tinst,max = 120 Nm
Wrench size SW = 30 mm
Base plate thickness t = 25 mm
Maximum possible fixing tfix,max = 71 mm
thickness
Maximum possible levelling tfix,max - tfix = 46 mm
layer

Base plate details


Units of Measurement Geometry: mm
Base plate thickness t = 25 mm
Clearance hole diameter df = 26 mm

Anchor coordinates
Anchor no. x y
mm mm
1 0 0

Attachment
Profile type None

The input values and the design results should be checked against local valid standards and approvals.
Please respect the disclaimer of warranty in the license agreement of the Software.

Page 6
C-FIX Online 1.1.58.1
Database version 1.1.60.0
Date 10/04/2024

Steel grade S235

The input values and the design results should be checked against local valid standards and approvals.
Please respect the disclaimer of warranty in the license agreement of the Software.