Professional Documents
Culture Documents
Report
Report
1
Database version 1.1.60.0
Date 10/04/2024
Deutschland
fis che r fixings UK Ltd
Whitely Road; Hithercroft Industrial Estate
Wallingford; Oxfordshire; OX10 9AT
technical@fischer.co.uk
Design specifications
Anchor
Anchor system fischer concrete screw UltraCut FBS II with hexagon
head and washer
Fixing element FBS II CP 8x55 5/- US,
CP
Anchorage depth 40 mm
Design data ETA-15/0352 (05.10.2020)
Units of Measurement
Geometry mm
Design action values kN, kNm
The input values and the design results should be checked against local valid standards and approvals.
Please respect the disclaimer of warranty in the license agreement of the Software.
Page 1
C-FIX Online 1.1.58.1
Database version 1.1.60.0
Date 10/04/2024
Input Data
Design method EN 1992-4:2018
Base material Normal weight concrete, C40/50, EN 206:2013
Concrete condition Non-cracked, Dry hole
Temperature range 24 °C Long term temperature, 40 °C Short term
temperature
Reinforcement No or standard reinforcement, No edge reinforcement
Drilling method Hammer drilling
Installation type Push-through installation
Annular gap Not filled
Type of loading Static or quasi-static
Base plate location Base plate flush installed on base material
Base plate geometry 50 mm x 50 mm x 5 mm
Profile type None
Steel failure
NRk,s γMs NRd,s NEd βN,s
kN kN kN %
35.00 1.40 25.00 1.00 4.0
The input values and the design results should be checked against local valid standards and approvals.
Please respect the disclaimer of warranty in the license agreement of the Software.
Page 2
C-FIX Online 1.1.58.1
Database version 1.1.60.0
Date 10/04/2024
Pullout failure
NRk,p ψc γMp NRd,p NEd βN,p
kN kN kN %
17.48 1.41 1.50 11.66 1.00 8.6
Interaction steel
Decisive utilisation for tensile loads βN,s = 0.04 ≤ 1
Decisive utilisation for shear loads βV,s = 0.69 ≤ 1
2 2
Decisive utilisation for the interaction βNV,s = βN,s + βV,s = 0.47 ≤ 1
Interaction concrete
Decisive utilisation for tensile loads βN,c/p = 0.09 ≤ 1
Decisive utilisation for shear loads βV,c/p = 0.67 ≤ 1
1.5 1.5
Decisive utilisation for the interaction βNV,c/p = βN,c/p + βV,c/p = 0.58 ≤ 1
Proof successful
The input values and the design results should be checked against local valid standards and approvals.
Please respect the disclaimer of warranty in the license agreement of the Software.
Page 3