Selective opening 2 stops in PH-RG.

Extra parts needed:

1) ALPK board to replace the ALSK board


2) The relays below if you ask for them

SCB CAR calls 406 for PH Floor - 407 for RG Floor.

ALPK Floor calls C6 for PH Floor - C7 for RG Floor.

2 free INPUTS I19=56 DOA I20=57 DOB.

2 free OUTPUTS S1-S1C=156 for PH Floor S2-S2C=157 for RG Floor.

Parameter two door selection B18=1 terminal input.

Parameter command system A02=2 down collective

NOTES

S1C-S2C=1000

RELAYS NEEDED

RL6A = 4 contacts 24vdc Landing PH A side

RL6B = 4 contacts 24vdc Landing PH B side

RC6A = 4 contacts 24vdc Car PH A side

RC6B = 4 contacts 24vdc Car PH B side

RL7A = 4 contacts 24vdc Landing RG A side

RL7B = 4 contacts 24vdc Landing RG B side

RC7A = 4 contacts 24vdc Car RG A side

RC7B = 4 contacts 24vdc Car RG B side

R156 = 2 contacts 24vdc Floor PH

R157 = 2 contacts 24vdc Floor RG

R39 = 4 contacts 24vdc Out of service disable all calls when out of service given

R120 = 4 contacts 24vdc Safety line disable all calls if safety line before 120 cut.