Download as pdf or txt
Download as pdf or txt
You are on page 1of 31

Climaveneta Technical Documentation

NECS-Y_0202T_0612T_201802_ML

REGULATION (EU) N. 2015/1095 FOR MEDIUM


TEMPERATURE PROCESS CHILLERS
Ecodesign requirements for process chillers

AIR COOLED CHILLERS

NECS-Y 0202T - 0612T


Cooling Capacity Range 26,2 - 87,7 [kW] - (EN14511 VALUE)
Nominal Cooling Capacity at TdesignC Range 26,2 - 87,7 [kW]
NECS-Y

1. REGULATION (EU) N. 2015/1095 FOR MEDIUM


TEMPERATURE PROCESS CHILLERS
1.1 Scope of the document 3
1.2 REGULATION (UE) N. 2015/1095 description 3
1.3 Description of the data declared by Mitsubishi 3
Electric Hydronics & IT Cooling Systems
2. CLIMAVENETA CONTENTS UNIT
2.1 Table index 4

3. TECHNICAL PARAMETERS
3.1 NECS-Y /B 5
3.2 NECS-Y /LN 14
3.3 NECS-Y /SL 23

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


2
NECS-Y

1. REGULATION (EU) N. 2015/1095 FOR MEDIUM


TEMPERATURE PROCESS CHILLERS
1.1 Scope of the document
This document is compliant with the Commission Regulation (EU) N.
2015/1095 regarding “REQUIREMENTS FOR PRODUCT INFORMATION”
(Annex VII, Point 2). In particular, it deals with medium temperature process
chillers and contains information required by Table 7 of the
above-mentioned regulation, which is entitled “Information requirements for
process chillers”.

1.2 REGULATION (UE) N. 2015/1095 description


The COMMISSION REGULATION (EU) N. 2015/1095 of 5 May 2015,
implementing Directive 2009/125/EC of the European Parliament and of the
Council, establishes eco-design requirements for the placing on the market
of: professional refrigerated storage cabinets and blast cabinets, condensing
units operating at low or medium temperature or both and process chillers
intended to operate at low or medium temperature. All these energy-related
products are defined in Article 2 of the Regulation in question.

1.3 Description of the data declared by Mitsubishi Electric Hydronics &


IT Cooling Systems
- Medium temperature process chiller: a product designed to cool down
and continuously maintain the temperature of a liquid to provide cooling
to a refrigerated appliance or system, whose aim is not to provide
cooling for the thermal comfort of human beings. It is capable of
delivering its rated refrigeration capacity at an indoor side heat
exchanger outlet temperature of
-8°C, at standard rating conditions.
- Rated refrigeration capacity (P): the refrigeration capacity that the
medium temperature process chiller is able to reach when operating at
full load at a specific rating point, expressed in kW.
- Seasonal Energy Performance Ratio (SEPR): the efficiency ratio of a
medium temperature process chiller at standard rating conditions,
representative of the variations in load and ambient temperature
throughout the year, and calculated as the ratio between the annual
refrigeration demand and the annual electricity consumption.
- Annual electricity consumption: result of the sum of the ratios between
each bin-specific cooling demand and the corresponding bin-specific
energy efficiency ratio, multiplied by the corresponding number of bin
hours.
- Degradation coefficient for chillers: measure of efficiency loss due to
cycling of the chiller.
- Capacity control: the ability of a chiller to change its cooling capacity by
changing the volumetric flow rate of at least one of the fluids needed to
operate the refrigeration cycle.

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


3
NECS-Y

2. CLIMAVENETA CONTENTS UNIT


2.1 Table index
AIR COOLED CHILLERS

NECS-Y 0202T - 0612T


Cooling Capacity Range 26,2 - 87,7 [kW]
Nominal Cooling Capacity at TdesignC Range 26,2 - 87,7 [kW]

Units Version Size Pag.


NECS-Y B 0202T 0252T 0302T 0352T 0412T 5
0452T 0512T 0552T 0612T
NECS-Y LN 0202T 0252T 0302T 0352T 0412T 14
0452T 0512T 0552T 0612T
NECS-Y SL 0202T 0252T 0302T 0352T 0412T 23
0452T 0512T

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


4
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /B 0202T
-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,32
Annual electricity consumption Q [kWh] 63175
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 28,30
Rated power input DA [kW] 15,50
Nominal EER EERA 1,82
Parameters at rating point B
Rated refrigeration capacity PB [kW] 26,41
Rated power input DB [kW] 10,30
Declared EER EERB 2,57
Parameters at rating point C
Rated refrigeration capacity PC [kW] 24,53
Rated power input DC [kW] 7,11
Declared EER EERC 3,45
Parameters at rating point D
Rated refrigeration capacity PD [kW] 22,64
Rated power input DD [kW] 6,29
Declared EER EERD 3,59
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


5
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /B 0252T
-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,12
Annual electricity consumption Q [kWh] 73643
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 31,00
Rated power input DA [kW] 18,20
Nominal EER EERA 1,70
Parameters at rating point B
Rated refrigeration capacity PB [kW] 28,93
Rated power input DB [kW] 12,00
Declared EER EERB 2,41
Parameters at rating point C
Rated refrigeration capacity PC [kW] 26,87
Rated power input DC [kW] 8,26
Declared EER EERC 3,26
Parameters at rating point D
Rated refrigeration capacity PD [kW] 24,80
Rated power input DD [kW] 7,39
Declared EER EERD 3,36
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


6
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /B 0302T
-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,27
Annual electricity consumption Q [kWh] 96663
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 42,60
Rated power input DA [kW] 22,40
Nominal EER EERA 1,90
Parameters at rating point B
Rated refrigeration capacity PB [kW] 39,76
Rated power input DB [kW] 15,40
Declared EER EERB 2,58
Parameters at rating point C
Rated refrigeration capacity PC [kW] 36,92
Rated power input DC [kW] 10,80
Declared EER EERC 3,40
Parameters at rating point D
Rated refrigeration capacity PD [kW] 34,08
Rated power input DD [kW] 9,78
Declared EER EERD 3,49
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


7
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /B 0352T
-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,24
Annual electricity consumption Q [kWh] 110395
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 48,19
Rated power input DA [kW] 25,60
Nominal EER EERA 1,88
Parameters at rating point B
Rated refrigeration capacity PB [kW] 44,99
Rated power input DB [kW] 17,50
Declared EER EERB 2,57
Parameters at rating point C
Rated refrigeration capacity PC [kW] 41,77
Rated power input DC [kW] 12,40
Declared EER EERC 3,38
Parameters at rating point D
Rated refrigeration capacity PD [kW] 38,56
Rated power input DD [kW] 11,20
Declared EER EERD 3,44
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


8
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /B 0412T
-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,19
Annual electricity consumption Q [kWh] 124088
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 53,35
Rated power input DA [kW] 29,00
Nominal EER EERA 1,84
Parameters at rating point B
Rated refrigeration capacity PB [kW] 49,84
Rated power input DB [kW] 19,60
Declared EER EERB 2,54
Parameters at rating point C
Rated refrigeration capacity PC [kW] 46,28
Rated power input DC [kW] 13,90
Declared EER EERC 3,34
Parameters at rating point D
Rated refrigeration capacity PD [kW] 42,72
Rated power input DD [kW] 12,60
Declared EER EERD 3,38
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


9
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /B 0452T
-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,23
Annual electricity consumption Q [kWh] 141788
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 61,85
Rated power input DA [kW] 32,20
Nominal EER EERA 1,92
Parameters at rating point B
Rated refrigeration capacity PB [kW] 57,77
Rated power input DB [kW] 22,10
Declared EER EERB 2,62
Parameters at rating point C
Rated refrigeration capacity PC [kW] 53,65
Rated power input DC [kW] 16,00
Declared EER EERC 3,36
Parameters at rating point D
Rated refrigeration capacity PD [kW] 49,52
Rated power input DD [kW] 14,40
Declared EER EERD 3,43
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


10
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /B 0512T
-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,23
Annual electricity consumption Q [kWh] 160440
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 69,87
Rated power input DA [kW] 36,00
Nominal EER EERA 1,94
Parameters at rating point B
Rated refrigeration capacity PB [kW] 65,24
Rated power input DB [kW] 24,70
Declared EER EERB 2,64
Parameters at rating point C
Rated refrigeration capacity PC [kW] 60,58
Rated power input DC [kW] 18,20
Declared EER EERC 3,33
Parameters at rating point D
Rated refrigeration capacity PD [kW] 55,92
Rated power input DD [kW] 16,30
Declared EER EERD 3,43
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


11
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /B 0552T
-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,30
Annual electricity consumption Q [kWh] 178966
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 79,60
Rated power input DA [kW] 41,50
Nominal EER EERA 1,92
Parameters at rating point B
Rated refrigeration capacity PB [kW] 74,29
Rated power input DB [kW] 28,20
Declared EER EERB 2,63
Parameters at rating point C
Rated refrigeration capacity PC [kW] 68,99
Rated power input DC [kW] 20,10
Declared EER EERC 3,43
Parameters at rating point D
Rated refrigeration capacity PD [kW] 63,68
Rated power input DD [kW] 18,10
Declared EER EERD 3,51
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


12
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /B 0612T
-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,23
Annual electricity consumption Q [kWh] 201001
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 87,69
Rated power input DA [kW] 47,90
Nominal EER EERA 1,83
Parameters at rating point B
Rated refrigeration capacity PB [kW] 81,85
Rated power input DB [kW] 32,40
Declared EER EERB 2,53
Parameters at rating point C
Rated refrigeration capacity PC [kW] 76,01
Rated power input DC [kW] 22,40
Declared EER EERC 3,39
Parameters at rating point D
Rated refrigeration capacity PD [kW] 70,16
Rated power input DD [kW] 20,30
Declared EER EERD 3,45
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


13
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /LN 0202T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,26
Annual electricity consumption Q [kWh] 61998
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 27,30
Rated power input DA [kW] 15,70
Nominal EER EERA 1,74
Parameters at rating point B
Rated refrigeration capacity PB [kW] 25,48
Rated power input DB [kW] 10,20
Declared EER EERB 2,50
Parameters at rating point C
Rated refrigeration capacity PC [kW] 23,66
Rated power input DC [kW] 6,92
Declared EER EERC 3,43
Parameters at rating point D
Rated refrigeration capacity PD [kW] 21,84
Rated power input DD [kW] 6,20
Declared EER EERD 3,51
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


14
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /LN 0252T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,20
Annual electricity consumption Q [kWh] 71236
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 30,80
Rated power input DA [kW] 18,00
Nominal EER EERA 1,71
Parameters at rating point B
Rated refrigeration capacity PB [kW] 28,75
Rated power input DB [kW] 11,60
Declared EER EERB 2,48
Parameters at rating point C
Rated refrigeration capacity PC [kW] 26,69
Rated power input DC [kW] 7,94
Declared EER EERC 3,36
Parameters at rating point D
Rated refrigeration capacity PD [kW] 24,64
Rated power input DD [kW] 7,16
Declared EER EERD 3,44
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


15
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /LN 0302T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,21
Annual electricity consumption Q [kWh] 97345
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 42,00
Rated power input DA [kW] 22,70
Nominal EER EERA 1,85
Parameters at rating point B
Rated refrigeration capacity PB [kW] 39,20
Rated power input DB [kW] 15,60
Declared EER EERB 2,52
Parameters at rating point C
Rated refrigeration capacity PC [kW] 36,40
Rated power input DC [kW] 10,90
Declared EER EERC 3,34
Parameters at rating point D
Rated refrigeration capacity PD [kW] 33,60
Rated power input DD [kW] 9,85
Declared EER EERD 3,41
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


16
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /LN 0352T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,04
Annual electricity consumption Q [kWh] 115372
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 47,29
Rated power input DA [kW] 26,90
Nominal EER EERA 1,76
Parameters at rating point B
Rated refrigeration capacity PB [kW] 44,15
Rated power input DB [kW] 18,30
Declared EER EERB 2,40
Parameters at rating point C
Rated refrigeration capacity PC [kW] 40,99
Rated power input DC [kW] 13,00
Declared EER EERC 3,16
Parameters at rating point D
Rated refrigeration capacity PD [kW] 37,84
Rated power input DD [kW] 11,60
Declared EER EERD 3,25
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


17
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /LN 0412T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,16
Annual electricity consumption Q [kWh] 127503
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 53,25
Rated power input DA [kW] 29,60
Nominal EER EERA 1,80
Parameters at rating point B
Rated refrigeration capacity PB [kW] 49,75
Rated power input DB [kW] 20,20
Declared EER EERB 2,46
Parameters at rating point C
Rated refrigeration capacity PC [kW] 46,19
Rated power input DC [kW] 14,30
Declared EER EERC 3,23
Parameters at rating point D
Rated refrigeration capacity PD [kW] 42,64
Rated power input DD [kW] 12,90
Declared EER EERD 3,30
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


18
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /LN 0452T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,15
Annual electricity consumption Q [kWh] 143603
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 60,45
Rated power input DA [kW] 33,40
Nominal EER EERA 1,81
Parameters at rating point B
Rated refrigeration capacity PB [kW] 56,47
Rated power input DB [kW] 22,60
Declared EER EERB 2,50
Parameters at rating point C
Rated refrigeration capacity PC [kW] 52,43
Rated power input DC [kW] 16,10
Declared EER EERC 3,25
Parameters at rating point D
Rated refrigeration capacity PD [kW] 48,40
Rated power input DD [kW] 14,60
Declared EER EERD 3,32
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


19
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /LN 0512T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,11
Annual electricity consumption Q [kWh] 162597
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 67,97
Rated power input DA [kW] 37,40
Nominal EER EERA 1,82
Parameters at rating point B
Rated refrigeration capacity PB [kW] 63,47
Rated power input DB [kW] 25,40
Declared EER EERB 2,50
Parameters at rating point C
Rated refrigeration capacity PC [kW] 58,93
Rated power input DC [kW] 18,30
Declared EER EERC 3,21
Parameters at rating point D
Rated refrigeration capacity PD [kW] 54,40
Rated power input DD [kW] 16,50
Declared EER EERD 3,30
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


20
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /LN 0552T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,17
Annual electricity consumption Q [kWh] 183196
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 77,20
Rated power input DA [kW] 43,40
Nominal EER EERA 1,78
Parameters at rating point B
Rated refrigeration capacity PB [kW] 72,05
Rated power input DB [kW] 29,20
Declared EER EERB 2,47
Parameters at rating point C
Rated refrigeration capacity PC [kW] 66,91
Rated power input DC [kW] 20,50
Declared EER EERC 3,26
Parameters at rating point D
Rated refrigeration capacity PD [kW] 61,76
Rated power input DD [kW] 18,60
Declared EER EERD 3,33
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


21
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /LN 0612T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,02
Annual electricity consumption Q [kWh] 207691
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 84,59
Rated power input DA [kW] 50,70
Nominal EER EERA 1,67
Parameters at rating point B
Rated refrigeration capacity PB [kW] 78,96
Rated power input DB [kW] 33,80
Declared EER EERB 2,34
Parameters at rating point C
Rated refrigeration capacity PC [kW] 73,32
Rated power input DC [kW] 23,10
Declared EER EERC 3,17
Parameters at rating point D
Rated refrigeration capacity PD [kW] 67,68
Rated power input DD [kW] 21,00
Declared EER EERD 3,23
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


22
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /SL 0202T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,04
Annual electricity consumption Q [kWh] 63787
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 26,20
Rated power input DA [kW] 16,60
Nominal EER EERA 1,58
Parameters at rating point B
Rated refrigeration capacity PB [kW] 24,45
Rated power input DB [kW] 10,60
Declared EER EERB 2,31
Parameters at rating point C
Rated refrigeration capacity PC [kW] 22,71
Rated power input DC [kW] 7,06
Declared EER EERC 3,21
Parameters at rating point D
Rated refrigeration capacity PD [kW] 20,96
Rated power input DD [kW] 6,41
Declared EER EERD 3,28
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


23
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /SL 0252T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 2,97
Annual electricity consumption Q [kWh] 74456
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 29,80
Rated power input DA [kW] 19,00
Nominal EER EERA 1,57
Parameters at rating point B
Rated refrigeration capacity PB [kW] 27,81
Rated power input DB [kW] 12,20
Declared EER EERB 2,27
Parameters at rating point C
Rated refrigeration capacity PC [kW] 25,83
Rated power input DC [kW] 8,29
Declared EER EERC 3,11
Parameters at rating point D
Rated refrigeration capacity PD [kW] 23,84
Rated power input DD [kW] 7,45
Declared EER EERD 3,20
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


24
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /SL 0302T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 2,98
Annual electricity consumption Q [kWh] 100763
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 40,50
Rated power input DA [kW] 23,80
Nominal EER EERA 1,70
Parameters at rating point B
Rated refrigeration capacity PB [kW] 37,80
Rated power input DB [kW] 16,20
Declared EER EERB 2,33
Parameters at rating point C
Rated refrigeration capacity PC [kW] 35,10
Rated power input DC [kW] 11,20
Declared EER EERC 3,12
Parameters at rating point D
Rated refrigeration capacity PD [kW] 32,40
Rated power input DD [kW] 10,20
Declared EER EERD 3,18
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


25
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /SL 0352T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,02
Annual electricity consumption Q [kWh] 117015
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 47,69
Rated power input DA [kW] 26,90
Nominal EER EERA 1,77
Parameters at rating point B
Rated refrigeration capacity PB [kW] 44,52
Rated power input DB [kW] 18,60
Declared EER EERB 2,39
Parameters at rating point C
Rated refrigeration capacity PC [kW] 41,34
Rated power input DC [kW] 13,20
Declared EER EERC 3,13
Parameters at rating point D
Rated refrigeration capacity PD [kW] 38,16
Rated power input DD [kW] 11,80
Declared EER EERD 3,24
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


26
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /SL 0412T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 3,06
Annual electricity consumption Q [kWh] 129312
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 53,35
Rated power input DA [kW] 30,00
Nominal EER EERA 1,78
Parameters at rating point B
Rated refrigeration capacity PB [kW] 49,84
Rated power input DB [kW] 20,50
Declared EER EERB 2,43
Parameters at rating point C
Rated refrigeration capacity PC [kW] 46,28
Rated power input DC [kW] 14,60
Declared EER EERC 3,18
Parameters at rating point D
Rated refrigeration capacity PD [kW] 42,72
Rated power input DD [kW] 13,10
Declared EER EERD 3,27
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


27
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /SL 0452T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 2,97
Annual electricity consumption Q [kWh] 148456
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 59,45
Rated power input DA [kW] 34,60
Nominal EER EERA 1,72
Parameters at rating point B
Rated refrigeration capacity PB [kW] 55,53
Rated power input DB [kW] 23,50
Declared EER EERB 2,36
Parameters at rating point C
Rated refrigeration capacity PC [kW] 51,57
Rated power input DC [kW] 16,70
Declared EER EERC 3,09
Parameters at rating point D
Rated refrigeration capacity PD [kW] 47,60
Rated power input DD [kW] 15,00
Declared EER EERD 3,17
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


28
<<< BACK INDEX UNITS
NECS-Y

NECS-Y /SL 0512T


-
Type of condensing Air cooled / Water cooled Air cooled
Refrigerant fluid(s) Information to identify the refrigerant fluid(s) intended to -
be used with the condensing unit
Type compressor driven vapour compression or sorption Compressor driven
process vapour compression
Operating temperature t [°C] -
Seasonal energy performance ratio SEPR 2,98
Annual electricity consumption Q [kWh] 164282
Parameters at full load and reference ambient temperature at rating point A
Rated refrigeration capacity PA [kW] 66,07
Rated power input DA [kW] 38,70
Nominal EER EERA 1,71
Parameters at rating point B
Rated refrigeration capacity PB [kW] 61,69
Rated power input DB [kW] 26,00
Declared EER EERB 2,38
Parameters at rating point C
Rated refrigeration capacity PC [kW] 57,29
Rated power input DC [kW] 18,50
Declared EER EERC 3,10
Parameters at rating point D
Rated refrigeration capacity PD [kW] 52,88
Rated power input DD [kW] 16,70
Declared EER EERD 3,18
Other items
Capacity control fixed/staged/variable Staged
Degradation coefficient for chillers CC 0,9
Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 - 31100 Treviso - Italy

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


29
NECS-Y

ENGLISH ITALIANO FRANCAISE DEUTSCH ESPANOL


Type of condensing Tipo di condensazione Type de condensation Art der Verflüssigung Tipo de condensación
Refrigerant fluid(s) Fluido(i) refrigerante(i) Fluide(s) frigorigène(s) Kältemittel Fluido o fluidos refrigerantes
Type Tipo Type Bauart Tipo
Operating temperature Temperatura di esercizio Température de service Betriebstemperatur Temperatura de funcionamiento
Seasonal energy performance Indice di prestazione energetica Ratio de performance Jahresarbeitszahl Factor de rendimiento energético
ratio stagionale énergétique saisonnier estacional
Annual electricity consumption Consumo annuo di energia Consommation annuelle Jahresstromverbrauch Consumo anual de electricidad
elettrica d'électricité
Parameters at full load and Parametri a pieno carico e alla Paramètres à pleine charge et à Parameter bei Volllast und Parámetros a plena carga y a
reference ambient temperature temperatura ambiente al punto la température ambiante de Bezugsumgebungstemperatur temperatura ambiente de
at rating point A di valutazione A référence au point d'évaluation am Bewertungspunkt A referencia en el punto de
A clasificación A
Rated refrigeration capacity Capacità dichiarata di Puissance de réfrigération Nennkälteleistung Potencia nominal de refrigeración
refrigerazione nominale
Rated power input Potenza nominale assorbita Puissance absorbée nominale Nennleistungsaufnahme Potencia utilizada nominal
Nominal EER EER nominale Coefficient d'efficacité Nennleistungszahl Factor de eficiencia energética
énergétique nominal nominal
Parameters at rating point B Parametri al punto di Paramètres au point Parameter am Parámetros en el punto de
valutazione B d'évaluation B Bewertungspunkt B clasificación B
Rated refrigeration capacity Capacità dichiarata di Puissance de réfrigération Nennkälteleistung Potencia nominal de refrigeración
refrigerazione nominale
Rated power input Potenza nominale assorbita Puissance absorbée nominale Nennleistungsaufnahme Potencia utilizada nominal
Declared EER EER dichiarato Coefficient d'efficacité Nennleistungszahl Factor de eficiencia energética
énergétique declaré nominal
Parameters at rating point C Parametri al punto di Paramètres au point Parameter am Parámetros en el punto de
valutazione C d'évaluation C Bewertungspunkt C clasificación C
Rated refrigeration capacity Capacità dichiarata di Puissance de réfrigération Nennkälteleistung Potencia nominal de refrigeración
refrigerazione nominale
Rated power input Potenza nominale assorbita Puissance absorbée nominale Nennleistungsaufnahme Potencia utilizada nominal
Declared EER EER dichiarato Coefficient d'efficacité Nennleistungszahl Factor de eficiencia energética
énergétique declaré nominal
Parameters at rating point D Parametri al punto di Paramètres au point Parameter am Parámetros en el punto de
valutazione D d'évaluation D Bewertungspunkt D clasificación D
Rated refrigeration capacity Capacità dichiarata di Puissance de réfrigération Nennkälteleistung Potencia nominal de refrigeración
refrigerazione nominale
Rated power input Potenza nominale assorbita Puissance absorbée nominale Nennleistungsaufnahme Potencia utilizada nominal
Declared EER EER dichiarato Coefficient d'efficacité Nennleistungszahl Factor de eficiencia energética
énergétique declaré nominal
Other items Altri elementi Autres caractéristiques Sonstige Produktdaten Otros elementos

Capacity control Dispositivo di controllo della Régulation de la puissance Leistungsregelung Control de la potencia
capacità
Degradation coefficient for Coefficiente di degradazione per i Coefficient de dégradation pour Minderungsfaktor von Kühlern Coeficiente de degradación de
chillers refrigeratori les refroidisseurs las enfriadoras
Declared energy efficiency Indice di efficienza energetica Coefficient d'efficacité Angegebene Leistungszahl Factor de eficiencia energética
ratio or gas utilisation dichiarato o efficienza dell'uso énergétique déclaré ou oder declarado o eficiencia del uso
efficiency/auxiliary energy del gas/fattore di energia rendement de la Gaswirkungsgrad/Hilfsenergiefaktor
de gas o factor de energía
factor for part load at given ausiliaria a carico parziale alle consommation de gaz/indice bei Teillast und bestimmten auxiliar para carga parcial a las
outdoor temperatures Tj temperature esterne date Tj énergétique auxiliaire à charge Außentemperaturen Tj temperaturas exteriores dadas
partielle pour des températures Tj
extérieures données Tj
Notes: Note: Remarques: Hinweise: Notas:
The parameters are declared for I parametri sono dichiarati per Les paramètres sont déclarés Die Parameter sind für eine Los parámetros se declararán
application at medium l’applicazione a temperatura pour l’application à moyenne Mitteltemperaturanwendung para aplicaciones de media
temperature, except in the case media, tranne per le pompe di température, excepté pour les anzugeben, außer für temperatura, excepto si se trata
of low temperature heat pumps. calore a bassa temperatura. Per pompes à chaleur basse Niedertemperatur-Wärmepumpen. de bombas de calor de baja
For low temperature heat pumps, le pompe di calore a bassa température. Pour les pompes à Für temperatura. En el caso de las
the parameters are declared for temperatura, i parametri sono chaleur basse température, les Niedertemperatur-Wärmepumpen bombas de calor de baja
application at low temperature. dichiarati per l’applicazione a paramètres sont déclarés pour sind die Parameter für eine temperatura, los parámetros se
bassa temperatura. l’application à basse température. Niedertemperaturanwendung declararán para aplicaciones de
anzugeben. baja temperatura.
Unit in standard Unità in configurazione ed Unité en configuration et Gerät mit Standard-Konfiguration Unidad en configuración y
configuration/execution, without esecuzione standard, priva di exécution standard, sans und -Ausführung, ohne ejecución estándar, sin
optional accessories. accessori opzionali. accessoires optionnels. wunschweises Zubehör. accesorios opcionales.

ELCA_Engine ver. 1.0.0.4 - DB ver. 1.0.0.0 NECS-Y_0202T_0612T_201802_ML


30
PRODUCT GUIDE_ENG_02-2018