Date: 5/24/2024
Time: 10:20 AM
Project:
Location:
Stability Checking for Hoarding (Type 2 & 2A)
Design Data
Height of Crub = 600 mm
Height of Balustrade = 1100 mm FOOTING

1700
Height of Fence = 1700 mm

1700
Loading width of Fence Board = 1000 mm

Reduction factor for temporary wind case = 1 0


1000
Concrete Density = 24.5
70
FOOTING 1000
Assumed friction angle to be = 30 °
Size of Footing B = 1000 mm 1000
SIDE FRONT
H = 700 mm
L = 1000 mm ᵠ = 50/116 = 0.43 ; Cf=1.67 ∴=0.43 x
Assume Solidity Ratio of value = 2 (For 0.6 curb) 0.7181 (For 1.1m balustrade) 1.67=0.7181

Wind Load
Design wind pressure q = 1.82 kPa For height above site-ground level < 5m
Design wind pressure q = kPa

Wind Load on Hoarding = 1 x (1.82 x 1 x (0.6 x 2 + 1.1 x 0.7181))


= 3.622 kN
Overturning Moment due to Wind Load = 1.82 x 2 x 0.6 x 1 + 1.82 x 0.7181 x 1.1 x 1.85
= 4.844 kNm
Resistance
Take moment at the edge of footing Force Moment arm
Resistance moment due to Footing = 24.5 x 0.7 x 1m = 17.15 x 0.5 = 8.58 kNm
Overturning Checking
8.58
Factor of Safety of overturing = = 1.77 > 1.5 OKAY
4.844
Sliding Checking
Frictional force = 17.15 x tan(2/3 x 30) = 6.242 kN
6.242
Factor of Safety of Sliding = = 1.72 > 1.5 OKAY
3.622
Bearing Checking
Area Distance from Rotation Point Second Moment of Area
Footing 1 1(B) x 0.7(H) x 1(L) 1 m² 0.5 m 0.083 m³
1 m² 0.083 m³
N.A. of the footings = 0.500 m from Rotation Point
17.150
Bearing stress of Footing = = 17.15 < 50 kPa OKAY
1.000
4.844 B
Eccentricity e = = 0.282 m > = 0.16667
17.150 6
4 x 17.15
Bearing stress of Footing (with Wind) = = 52.446 < 62.5 kPa OKAY
3 x 1(1-2x0.282)
Page: 1 of 1
Date: 5/24/2024
Time: 10:20 AM
Project: CC158 STEEL RAIL

Location: Mai Po
Stability Checking for Hoarding (Fence Board)
Design Data
0
Height of Fence = 2400 mm
5950
550

2400
Loading width of Fence Board = 3300 mm FOOTING

2400
Loading widht of Gantry = 3000 mm
Gantry height = 5950 mm 0

Gantry clear height = 5500 mm


100

Reduction factor for temporary wind case = 0.37


800
Concrete Density = 24.5 3300
FOOTING 3300 3000
Assumed friction angle to be = 30 ° SIDE FRONT
Size of Footing B = 800 mm
H = 1000 mm
L = 3300 mm
Assume Solidity Ratio of Gantry = 0.2

Wind Load
Design wind pressure q = 1.82 kPa For height above site-ground level < 5m
Design wind pressure q = 1.86 kPa For height above site-ground level at 5.95 m

Wind Load on Hoarding = 0.37 x (1.82 x 3.3 x 2.4 + 1.82 x 3 x 2.4 x 0.2 + 1.86 x 3 x 0.45) + 0.37x1.82x0.2x2x4.5
= 8.44412 kN
Overturning Moment due to Wind Load = 0.37 x (1.82 x 3.3 x 2.4^2/2 + 1.82 x 3 x 2.4^2/2 x 0.2 + 1.86 x 3 x 0.45 x 5.725) + 1.22x(4.5/2+1)
= 16.8224 kNm

Resistance
Take moment at the edge of footing Force Moment arm
Member self weight = = 4.29 x 0 = 0.000
Resistance moment due to Footing = 24.5 x 0.8 x 1 x 3.3 = 64.68 x 0.4 = 25.872 kNm
Overturning Checking
25.872
Factor of Safety of overturing = = 1.54 > 1.5 OKAY
16.82239
Sliding Checking
Frictional force = 64.68 x tan(2/3 x 30) = 23.542 kN
23.542
Factor of Safety of Sliding = = 2.79 > 1.5 OKAY
8.44412
Bearing Checking
Area Distance from Rotation Point Second Moment of Area
Footing 1 0.8(B) x 1(H) x 3.3(L) 3.2775 m² 0.4 m 0.141 m³
Assume 75mm pavement and 45° load distribution. 3.2775 m² 0.141 m³
N.A. of the footings = 0.400 m from Rotation Point 50
64.680
Bearing stress of Footing = = 19.73 < 100 kPa OKAY
3.278
16.822 B
Eccentricity e = = 0.260 m > = 0.133
64.680 6
4 x 64.68
Bearing stress of Footing (with Wind) = = 58.133 < 125 kPa OKAY
3 x 3.45(0.95-2x0.26)
Page: 1 of 1
Date: 5/24/2024
Time: 10:20 AM
STEEL RAIL
Project: CC158
Location: Mai Po
Stability Checking for Hoarding (Fence Board)
Design Data
5950 0
Height of Fence = 2400 mm 550

Loading width of Fence Board = 2400 mm


Loading widht of Gantry = 3000 mm
Gantry height = 5950 mm 0

2400
Gantry clear height = 5500 mm

2400
800 100 800
FOOTING
Reduction factor for temporary wind case = 0.37
800 1000
Concrete Density = 24.5 1500 0
2400
FOOTING
Assumed friction angle to be = 30 ° SIDE 2400 3000
FRONT
Spacing between Footing = 0 mm
Size of Footing B = 800 mm
H = 1000 mm
L = 2400 mm
Size of Footing 2 B = 1500 mm Height of Fold Gate H1 = 4500 mm
H = 800 mm
L = 1000 mm
Assume Solidity Ratio of Gantry = 0.2

Wind Load
Design wind pressure q = 1.82 kPa For height above site-ground level < 5m
Design wind pressure q = 1.86 kPa For height above site-ground level at 5.95 m

Wind Load on Hoarding = 0.37 x (1.82 x 2.4 x 2.4 + 1.82 x 3 x 2.4 x 0.2 + 1.86 x 3 x 0.45) + 0.37x1.82x0.2x3x2.1
= 6.62648 kN
Overturning Moment due to Wind Load = 0.37 x (1.82 x 2.4 x 2.4^2/2 + 1.82 x 3 x 2.4^2/2 x 0.2 + 1.86 x 3 x 0.45 x 5.725) + 0.85x(4.5/2+2.4)
= 15.0825 kNm
Resistance
Take moment at the edge of footing Force Moment arm
Member self weight = = 4.29 x 0 = 0.000
Resistance moment due to Footing 1 = 24.5 x 0.8 x 1 x 2.4 = 47.04 x 0.4 = 18.816
Resistance moment due to Footing 2 = 24.5 x 1.5 x 0.8 x 1 = 29.40 x 1.55 = 45.570
= 80.73 = 64.386 kNm
Overturning Checking
64.386
Factor of Safety of overturing = = 4.27 > 1.5 OKAY
15.0824506
Sliding Checking
Frictional force = 80.7322 x tan(2/3 x 30) = 29.384 kN
29.384
Factor of Safety of Sliding = = 4.43 > 1.5 OKAY
6.626484
Bearing Checking
Area Distance from Rotation Point Second Moment of Area
Footing 1 0.8(B) x 1(H) x 2.4(L) 2.4225 m² 0.4 m 0.720 m³
Footing 2 1.5(B) x 0.8(H) x 1(L) 1.8975 m² 1.55 m 1.071 m³
Assume 75mm pavement and 45° load distribution. 4.32 m² 1.791 m³
N.A. of the footings = 0.905 m from Rotation Point
80.732
Bearing stress of Footing = = 18.69 < 100 kPa OKAY
4.320
15.082 B
Eccentricity e = = 0.134 m > = 0.133
80.732 6
4 x 80.7322
Bearing stress of Footing (with Wind) = = 61.896 < 125 kPa OKAY
3 x 2.55(0.95-2x0.134)