Honeywell Indoor Air Quality Monitor

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

TAKE A NEW

APPROACH
TO CLEANER &
HEALTHIER
AIR
When air pollutants
compromise your wellbeing,
take the first step to cleaning
the air by knowing its quality.

Indoor Air Quality Monitor

#KnowYourAir
CONTAMINATED AIR
CAN PUT YOUR
HEALTH AT RISK
Airborne pollutants are a big cause of
increasing ill-health. What’s worse is that when
contained indoors, the pollutants can quickly
rise to harmful levels, adversely affecting daily
life and compromising your overall wellness.
That is why monitoring indoor air quality for
pollutants can be the key to living healthier.

2 | www.honeywell.com | Indoor Air Quality Monitor


Indoor Air Quality Monitor | www.honeywell.com | 3
CAUSES OF AIR CONTAMINATION
Toxic chemicals in building materials, cleaning products,
appliances, furniture, or even biological contaminants
like viruses or bacteria can pose serious health risks.

Shortcomings in HVAC systems, VOCs,


moulds, cleaning chemicals, or lack
of adequate fresh-air intake or
filtration could lead to Sick Building
Syndrome. In this condition,
building occupants experience
varied cold or flu-like symptoms,
asthma attacks, and more.

4 | www.honeywell.com | Indoor Air Quality Monitor


AIR QUALITY MATTERS
51% of workers state that the fear of getting sick from being
*

at work would be a barrier to return to their office.

Incorrect Extreme fluctuation of Inhaling elevated levels


temperatures can relative humidity can of Particulate Matter
weaken health expose occupants to can lead to various
and productivity infectious particles cardiopulmonary issues

Emerging evidence Exposure to various volatile organic compounds


suggests that CO2 exposure (VOCs) such as benzene, formaldehyde or
may lead to impaired toluene can lead to irritation of eyes, nose and
decision-making throat as well as kidney and liver damage

KNOW YOUR AIR TO CREATE A HEALTHY ENVIRONMENT


The Honeywell Indoor Air Quality Monitor will help you know your air
at a glance. Now you will be able to take better care of your occupant’s
well-being by taking right measures to tackle air pollution.

*Sources: PWC Americas -Reboot: Employees want safety and well-being prioritized
(https://www.pwc.com/us/en/library/covid-19/employees-anxious-about-
returning-to-workplace.html)

ASHRAE-healthcare-c19-guidance (https://www.ashrae.org/file%20library/
technical%20resources/covid-19/ashrae-healthcare-c19-guidance.pdf)

Indoor Air Quality Monitor | www.honeywell.com | 5


INDOOR AIR
QUALITY MONITOR
This convenient and compact device monitors the air around you for
the most common pollutants and allergens including temperature,
relative humidity, particulate matter, carbon dioxide, total volatile
organic compounds (TVOC), formaldehyde*, O3*, Sox*, Nox*

The AQI measured in real time by the device indicates the quality
of air around you, which in turn can be used to find out the possible
ill effects of the air on your cognitive abilties. Now take measures
to ensure that your occupants breathe clean air, everyday.

6 | www.honeywell.com | Indoor Air Quality Monitor


Indoor Air Quality Monitor | www.honeywell.com | 7
The Indoor Air Quality Monitor uses two Maglev fans to draw an active air sample,
enabling laminar flow across the array of sensors for more accuracy. The device is
pre-configurable with optional sensors viz. Formaldehyde (HCHO), Ozone (O3)*,
SOX*, NOX* as part of the unit.
Building occupants can view the parameters of air quality and its index via the
3.5” TFT screen on board. The Monitor can also communicate to any Building
Management System (BMS) using MODBUS protocol through the RS485 port.

KEY FEATURES

Wide array of Modular architecture: Active sampling with a


configurable hi- 5+2 for optimal Maglev fan for climate
accuracy sensors configuration and gas sensors

Large 3.5” TFT screen BMS Advanced Honeywell particulate


for clear visual compatible sensor, laser-based, light-
scattering, particle-sensing

8 | www.honeywell.com | Indoor Air Quality Monitor *future releases


MULTIPLE DASHBOARDS FOR AIR QUALITY INSIGHTS
The Indoor Air Quality monitor is designed with subtle aesthetics to fit perfectly
into most indoor environments. Loaded with features, it provides information
in a user-friendly way by using colour codes to indicate the air quality. You just
have to tap on the device screen to switch between the individual parameters.

Now choose between fresh white and robust black shades to match your decor
and simply mount it on your wall, ceiling or table.

All Parameter view Air Quality Index

Real time Parameter name

Indoor Air Quality Monitor | www.honeywell.com | 9


INDOOR AIR QUALITY
MONITOR
FROM THE INSIDE
Get an in-depth view of
Advanced Sensor
how the device works Platform 5+2
Architecture
Modular Sensor array
with grouped and
pre-defined sensors
Analog, UART, I2C

3.5’ LCD Touch


Screen
Capacitive Touch
Screen Clear
Parameters Visuals
AQI Indicator

Top Cover Honeywell PM2.5


Blends into the and PM10
interior design of High Accuracy
every building advanced PM2.5 &
PM10 Sensor

10 | www.honeywell.com | Indoor Air Quality Monitor


Airflow

Active Suction Fan’-Maglev


Ensures Laminar Flow
across the sensing elements
‘First in Segment’
PM2.5 and
PM10
Chamber

32 Bit powerful Dual


Core SoC Processor Bottom Casing

Indoor Air Quality Monitor | www.honeywell.com | 11


HOW IT WORKS
INSIDE A
BUILDING
Here’s how the Indoor Air Quality Monitor ensures
that your working environment is safer.

ENTERPRISE MULTI-SITE
Portfolio manager director / C-suite
Informed decision-making and actionable insights with a healthy building score, portfolio analytics

Zone 2 Zone 1

IAQ

Zone 3

IAQ

IAQ

IAQ Kiosk Display

MODBUS RS 485

IAQ

IAQ
Zone 7

IAQ

Zone 4

Zone 6

Zone 5

12 | www.honeywell.com | Indoor Air Quality Monitor


SINGLE BUILDING
BMS SUPERVISOR, SECURITY OPERATOR : Guided resolution with alarms and SOPs
Get zone-wise information monitored at BMS or central location

Alarm Healthy building All zone Zone wellness & Zone


Console notification summary summary configurations

MODBUS RS 485

Zone 1 Zone 2 Zone End

Indoor Air Quality Monitor | www.honeywell.com | 13


PRODUCT SPECIFICATION
TECHNICAL INFORMATION
DETAIL SPECIFICATION
5 in one Standard sensor: Temperature (T) , Relative Humidity (RH.), Particulate Matter (PM2.5) and
Detection parameter (PM10), Total Volatile Organic Compound (TVOC), Carbon Dioxide (C02)
Optional Sensors: Formaldehyde (HCHO), Ozone (O3)*
Display Model: 3.5” Colour TFT touchscreen
Display
Non-Display Model: LED Indicators
IAQ monitor power supply 12 VDC
Operating temperature 0 to 70 °C (32 to 158°F)
Humidity 0 to 90% Rh. (Non-condensing)
Storage condition -10 to 50 °C (14 to 122°F)
Output RS-485/RTU (MODBUS)
Without rear mounting plate: 160 mm × 160 mm × 55 mm
Dimensions
Mounting plate: 130 mm × 140 mm × 2.5 mm
Net weight 520 gms. (1.15 lbs.)
Enclosure and IP level Polycarbonate (RoHS), IP20
Display Model: Air quality index value and status are displayed on the touchscreen.
Air quality index (AQI) Non-Display Model: Air quality index status is indicated using a LED (Green(Good), Yellow
(Moderate), and Red (Unhealthy).

SENSOR SPECIFICATION - BASE PACKAGE


PARAMETER DETAIL SPECIFICATION
Sensor output resolution 0.1⁰C
Measuring range -10 to 70 ⁰C
Temperature
Accuracy ± 0.3 ⁰C
Performance check and re-calibration Yes / Replacement kit
Sensor output resolution ±2 %
Measuring range Upto 100 %
Relative Humidity
Accuracy ±3%
Performance check and re-calibration Yes / Replacement kit
Sensor output resolution 5 µg/m³
Measuring range 0-45000 µg/m³
TVOC
Accuracy ±1 % full scale
Performance check and re-calibration Auto-calibration
Sensor output resolution 1 ppm
Measuring range up to 5000 ppm
CO2 (NDIR)
Accuracy ±1% full scale
Performance check and re-calibration Auto-calibration
Sampling Type Active airflow
Sensor output resolution 1 µg/m3
PM2.5 and PM10 Measuring range 0 to 1000 µg/m3
Accuracy ±5% full scale
Performance check and re-calibration Yes / Replacement kit

14 | www.honeywell.com | Indoor Air Quality Monitor


SENSOR SPECIFICATION - OPTIONAL
PARAMETER DETAIL SPECIFICATION
Sensor output resolution 100 ppb

Formaldehyde Measuring range 0 - 50,000 ppb


(HCHO)* Accuracy ± 15% full scale
Performance check and re-calibration Yes / Replacement kit
Sensor output resolution 1 ppb

Ozone Measuring range 0 to 1000 ppb


O3 Accuracy ±1% full scale
Performance check and re-calibration Yes / Replacement kit

Note:
• Sensors specifications, accuracies are as per standard test procedures in lab conditions. The test conditions for each of the native sensors
could vary depending on the type of native sensor.
• PM Sensors are tested and calibrated with a smoke & dust mix in a proportion.
• For customized applications in specific or varying indoor environments, buyers are required to provide corresponding end conditions for such
specific calibrations.

Indoor Air Quality Monitor | www.honeywell.com | 15


HEALTHIER AIR
CREATES HEALTHIER
SPACES
Create a better environment, so you can maximize
focus, well-being, and productivity.

APPLICATION AREAS
Honeywell Indoor Air Quality Monitor can be installed in intelligent buildings and systems, air quality data collection
systems, green building evaluation systems, and ventilation systems. Whether you need to protect your building occupants
or just want to optimize your indoor environment, this device will give you an insight into the air you’re breathing.

Restaurants Hotels Hospitals

Schools Universities Offices

For more information,


www.honeywellbuildings.in
Call: 000-8000-502167
Disclaimer:
Email: HBT-Indiabuildings@honeywell.com Due to continuous product upgrade the
specifications are subject to change, please
contact the local sales office for more details.

Honeywell HBT India Buildings The image of the IAQ monitor is an illustration, colour
Unitech Trade Center, 5th Floor, Sector-43, references could change in the actual model.

Block C, Sushant Lok Phase - I, Indoor Air Quality Monitor | 01 | 09/21


Gurgaon - 122 002. © 2022 Honeywell International Inc.

You might also like