NEW ACCURATE WAVENUMBERS OF H35Cl AND H37Cl ROVIBR

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

See discussions, stats, and author profiles for this publication at: https://www.researchgate.

net/publication/301369556

NEW ACCURATE WAVENUMBERS OF H35Cl+ AND H37Cl+ ROVIBRATIONAL


TRANSITIONS IN THE v=0−1 BAND OF THE 2Π STATE.

Conference Paper · June 2015


DOI: 10.15278/isms.2015.RD08

CITATIONS READS

0 29

6 authors, including:

Jose Luis Domenech Brian J. Drouin


Spanish National Research Council NASA
108 PUBLICATIONS 1,326 CITATIONS 364 PUBLICATIONS 10,744 CITATIONS

SEE PROFILE SEE PROFILE

J. Cernicharo I. Tanarro
Instituto de Ciencia de Materiales de Madrid Spanish National Research Council
1,007 PUBLICATIONS 25,805 CITATIONS 143 PUBLICATIONS 1,979 CITATIONS

SEE PROFILE SEE PROFILE

All content following this page was uploaded by I. Tanarro on 09 August 2018.

The user has requested enhancement of the downloaded file.


NEW ACCURATE WAVENUMBERS OF H35 Cl+ AND H37 Cl+ ROVIBRATIONAL TRANSITIONS IN THE v = 0 − 1
BAND OF THE 2 Π STATE.

JOSE LUIS DOMENECH, MAITE CUETO, VICTOR JOSE HERRERO, ISABEL TANARRO, Molecular
Physics, Instituto de Estructura de la Materia (IEM-CSIC), Madrid, Spain; JOSE CERNICHARO, Molecular
Astrophysics, ICMM, Madrid, Spain; BRIAN DROUIN, Jet Propulsion Laboratory, California Institute of
Technology, Pasadena, CA, USA.

HCl+ is a key intermediate in the interstellar chemistry of chlorine. It has been recently identified in space from
Herschel’s spectraa and it has also been detected in the laboratory through its optical emissionb , infraredc and mm-wave
spectrad . Now that Hershchel is decomissioned, further astrophysical studies on this radical ion will likely rely on ground-
based observations in the mid-infrared. We have used a difference frequency laser spectrometer coupled to a hollow
cathode discharge to measure the absorption spectrum of H35 Cl+ and H37 Cl+ in the v = 0 − 1 band of the 2 Π state
with Dopppler limited resolution. The accuracy of the individual measurements (∼ 10 MHz (3σ)) relies on a solid state
wavemeter referenced to an iodine-stabilized Ar+ laser. The new data are being fit using the CALPGM software from JPL,
and the current status will be presented.
a M. De Luca et al., Astrophys. J. Lett. 751, L37 (2012)
b W. D. Sheasley and C. W. Mathews, J. Mol. Spectrosc. 47, 420 (1973)
c P. B. Davies, P. A. Hamilton, B. A. Johnson, Mol. Phys. 57, 217 (1986)
d H. Gupta, B. J. Drouin, and J. C. Pearson, Astrophys. J. Lett. 751, L37 (2012)

View publication stats

You might also like