NTPC APROVE SELETED VENDOR MATERIAL STATUS Mobile number

SL NO Item Description SYMBOL SIZE (M) MARK QTY VENDOR LIST NAME DETAIL DRAWING at site REMARK

SUBMITTED APPROVED
1 STEEL DOOR DI 1.200*2.100 NOS 3
SRESHTA SOLUTIONS
PRE LIMINATED SOLID CORE 1.000*2.100 ,
2 WOODEN FLUSH DOOR AND D2,D3 0.750*2.100 NOS 4
STEEL FRAME

ANODIED ALUMINUM GLAZED


3
DOOR WITH 6MM THK .CLEAR D4 1.200*2.10 NOS 1
TOUGHENED GLASS. (SINGLE
SHUTTER)

4
FIRE DOOR AS FDI 1.200*2.103 NOS 14 25.08.2023 PENDING
/SPECIFICATION(SINGLE DOOR)

FIRE DOOR AS Shakti Hormann


5
/SPECIFICATION(Double DOOR) FD2 2.000*3.000 NOS 2 Private Limited 25.08.2023 PENDING 30.09.23
Ramesh-8688873727

6 ROLLING SHUTTER AS PER SPEC. RS1 3.55*3.5 NOS 1 28.08.2023 PENDING 30.09.23
Ram- 8121018338

ANODIED ALUMINUM GLAZED


7
WINDOW PARTLY OPENABLE W1 1.200*2.500 NOS 20 05.09.2023 PENDING
AND PARTLY FIXING WITH 6MM
THICK TOUGHENED GLASS

ANODIED ALUMINUM GLAZED


8 VENTILATER WITH 6MM THICK V1 2.500*0.600 NOS 26 05.09.2023 PENDING SANDEEP 9652967101
TOUGHENED GLASS
ANODIED ALUMINUM GLAZED
9 VENTILATER WITH 6MM THICK V2 2.000*0.600 NOS 9 05.09.2023 PENDING
TOUGHENED GLASS
ANODIED ALUMINUM GLAZED
10 VENTILATER WITH 6MM THICK V3 0.900*0.600 NOS 2 05.09.2023 PENDING
TOUGHENED GLASS

IPS FLOORING (CEMENT


11
CONCRETE FLOORING) WITH IPS SQM 18,052 FRONT NOT CLEAR ( AFTER
12MM THICK METALLIC PANEL FIXING)
HARDENER TOPING

ACRYLIC DISTEMPER PAINT Ceiling:- PAINTING WORK IS GOING


12 (INTERNAL WALL FINISH ,CEILING SQM 7,670 Primer - Manpower - 1st floor with ON
FINISH) 400ltr 04 nos Gate primer and single
Asian Paint , Colour shade approved by Distemper- pass in coat completed by
25.08.23 200Kg process 31.08.23

ACRYLIC EMULSION PAINT FRONT NOT CLEAR ( SLAB


13 OVER 2MM THICK POLYMER SQM 500 Wall:- Distemper by 29.08.23 SHUTTERING IN PROGRESS @
BASED WATER RESISTANT PUTTY 22.000M)

MIRROR POLISHED VITRIFIED FRONT NOT CLEAR ( SLAB


14
CERAMIC TILES SQM 561 SHUTTERING IN PROGRESS @
22.000M)
18 MM THICK POLISHED FRONT NOT CLEAR ( SLAB
15
GRANITE STONE SQM 211 SHUTTERING IN PROGRESS @
22.000M)

MINERAL FIBER BOARD FALSE FRONT NOT CLEAR ( SLAB


16
CELLING GRID PATTERN 600*600 SQM 500 SHUTTERING IN PROGRESS @
22.000M)

17
ACID/ALKALI RESISTANT TILES 20MM SQM 202 KERA TECH OK OK 10.09.2023
(FLOOR) THICK 11.000*15.400,
ACID/ALKALI RESISTANT 12MM 11.000*5.050
18
DADO(WALL) THICK SQM 91 OK OK 10.09.2023
WORK START AT 15.09.2023
ACID/ALKALI RESISTANT
19 CHLORINATED RUBBERPAINT SQM 203 OK OK 10.09.2023
FOR BALANCE HEIGHT

20
150 DIA GALVANLZED MILD 110
STEEL RAIN WATER PIPE

22
1000 WIDE CHEQUERED TILE SQM 286
PATH WAY FRONT NOT CLEAR ( SLAB
SHUTTERING IN PROGRESS @
25 WATER PROOFING SQM 3,460 22.000M)
26 GLASS PARTITION SQM 23
23

24
FGD CONTROL BUILDING FLOOR WISE DETAILS
DOOR VENTELATER
D4 WINDOW ROLLING
FIRE DOOR(FD2 ) 2.500*1.200 V1 V2 V3
Floor D1 D2 D3 FIRE DOOR (FD1 ) SHUTTER
2.000*3.000 M 2.500*0.600 2.000*0.600 0 .900*0.600
SL NO 1.200*2.100 M 0.900*2.100 M 0.750*2.100 M 1.200*3.000M 1.200*2.100 M 3.550*3.500
A B C D E F G H I J K
GROUND FLOOR (CABLE
1 2 0 0 0 3 0 0 0 9 2 0
CELLAR ROOM)

1st FLOOR (SWITCH GEAR


2 0 1 1 0 2 0 12 1 0 2 1
ROOM)

3 2nd FLOOR 6 17 2

4 3rd FLOOR (PANEL ROOM) 1 1 2 2 7 2 1

5 3rd FLOOR (AHU ROOM)

3rd FLOOR (CONTOL


6 1 1 `
ROOM)

7 4th floor & stair case 1 1 1

NOS 3 2 2 1 14 2 20 1 26 9 2
SQM 7.56 3.78 3.15 3.6 35.28 12 60 12.425 39 10.8 1.08

Providing and fixing steel doors, those shall consist of double plate flush door shutters. The door shutter shall be 45 mm thick with two outer sheets of 18 G
A STEEL DOOR rigidly connected with continuous vertical 20 G stiffeners at the rate of 150 mm centre to centre. Side, top and bottom edges of shutters shall be reinforced by
continuous pressed steel channel with minimum 18 G. The door shall be sound deadened by filling the inside void with mineral wool. The door shall be sound
deadened by filling the inside void with mineral wool. Doors shall be complete with all hardware and fixtures like tower bolts, stoppers, aldrops,of Godrej or
equivalent make.

PRE LIMINATED SOLID CORE WOODEN FLUSH Providing, fitting and fixing factory made pre-laminated solid core flush door shutter as per IS 2202 (Part 1 & Part 2) with pressed steel door frame, 35mm thick
B,C homogenous particle board bonded with BWP type phenolformaldihyde synthetic resin, partical board core conforming to IS 3087 type I, 35x12 mm thick
DOOR AND STEEL FRAME
teakwood beading all around including preparation of working drawings. godrej or equivalent make mortice lock with handels on both sides,approved ISI mark
anodised fittings like door stopper,300mm long tower bolts,16x300mm long aldrops ,125mm long handles on both sides etc. butt hinges, sliding bolt, knobs, (all
fittings shall be anoidised aluminium color dyed), finish synthetic paint over primer, screws etc. all complete as per drawing, specification and instruction of
engineer in charge. with commercial faces and teak wood edges. (Finish painting paid separately)

ANODIED ALUMINUM GLAZED DOOR WITH


D 6MM THK .CLEAR TOUGHENED GLASS. Providing and fixing anodized hollow extruded aluminium doors (single or double shutter) conforming to IS:1948, IS:1949 fabricated from extruded sections of
(SINGLE SHUTTER) HINDALCO/JINDAL/INDAL or equivalent make having minimum 2mm wall thickness as per IS:1285, IS:733 and anodized and electro color coating of required
shade as per IS 1868 ( minimum anodized coating of grade AC15 ). fixed with rawl plugs, expansion fasteners,SS screws / fixing clips necessary filling of gaps at
Junctions, at top, bottom & sides with required PVC / neoprene felt for bi-metallic protection etc. Glazing shall be clear float/toughened glass of 6mm thickness
including snap fit type beading, concealed screws, fixtures, Godrej or equivalent make Mortice lock with handle on both sides, etc all complete. Aluminium
section shall be smooth, free of stains, straight, mitred & jointed mechanically wherever required. (Glazing shall be paid separately)
Providing and fixing fire proof steel doors (single or double shutter) with panic devices shall be 45mm thk flush design comprising of two outer sheets of 18
E FIRE DOOR AS /SPECIFICATION(SINGLE DOOR) gauge steel sheets rigidly connected and reinforced inside with continuous vertical 20 gauge stiffeners, spot welded in position at not more than 150mm on
centers including all fittings, vision panel of minimum 11mm thick inter layered fire resistant glass, shop painting with approved post office/signal red color fire
resistant paint and mineral wool insulation (64 kg/cum density) complete and shall be fire proof as per IS:3614, TAC requirements and as per specification.
FIRE DOOR AS /SPECIFICATION(DOUBLE Minimum ratings shall be 2 Hrs.
F
DOOR)

Providing and fixing in position rolling shutter of hot rolled double dipped galvanised steel lath section of 18 SWG tested mild steel strips at 75mm
rolling centres interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed
pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation including wire springs, top
cover, primer & shop coats of approved enamel paint etc, all complete as per IS 6248 and specification of approved make of following types: The
G ROLLING SHUTTER AS PER SPEC. bottom lath shall be coupled to a lock plate fabricated from 3mm thick galvanised steel plate and securely rivetted with stiffening angles.(partly
coiled and lath/full lath).

1, Mechanically Operated
2, Electrically & Manually operated

ANODIED ALUMINUM GLAZED WINDOW


H PARTLY OPENABLE AND PARTLY FIXING WITH
6MM THICK TOUGHENED GLASS

Providing, fixing and fitting of glazing of first grade class in line with IS 3548 in steel/aluminium/wooden frames, where ever required, cleaning after fixing
including hardware, gaskets, clips, beadings etc. all complete.

ANODIED ALUMINUM GLAZED VENTILATER


I,J,K
WITH 6MM THICK TOUGHENED GLASS
FGD CONTROL BUILDING FLOOR WISE DETAILS

ACRYLIC EMULSION
IPS FLOORING (CEMENT 150 DIA 18MM THICK
ACRYLIC DISTEMPER PAINT PAINT OVER 2MM MIRROR POLISHED MINERAL FIBER BOARD ACID/ALKALI ACID/ALKALI 1000 WIDE
CONCRETE FLOORING) WITH Designer ceramic Heavy duty dust GALVANLZED GLASS POLISHED WATER
SL NO Floor (INTERNAL WALL THICK POLYMER BASED VITRIFIED CERAMIC FALSE CELLING GRID RESISTANT TILES RESISTANT CHEQUERED TILE
12MM THICK METALLIC tiles pressed ceramic tiles MILD STEEL RAIN PARTITION GRANTE PROOFING
FINISH ,CEILING FINISH) WATER RESISTANT TILES PATTERN 600*600 (FLOOR) DADO(WALL) ACID/ALKALI PATH WAY
HARDENER TOPING WATER PIPE STONE
PUTTY RESISTANT
CHLORINATED
RUBBERPAINT FOR
BALANCE HEIGHT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

GROUND FLOOR (CABLE


1 1428 1820
CELLAR ROOM)

1st FLOOR (SWITCH GEAR


2 1140 2505 25 8 12
ROOM)

3 2nd FLOOR 1226 1901 202 91.29 185


102 286 192
4 3rd FLOOR (PANEL ROOM) 347 25 8 449 449

5 3rd FLOOR (AHU ROOM) 242.5 629

6 3rd FLOOR (CONTOL ROOM) 152 112 20 12

7 4th floor & stair case 118 1475

SQM 4036.5 6973 499 50 16 561 449 202 91.29 185 102 286 20 192 1499
wastage 10% 4440.15 7670.3 548.9 55 17.6 617.1 493.9 222.2 100.129 203.5 112.2 314.6 22 211.2 1648.9

IPS FLOORING (CEMENT CONCRETE Providing and laying 50 mm thick heavy duty cement concrete in flooring with metallic hardener pigmented topping 12mm thick uniform graded treated iron paricles in
1 FLOORING) WITH 12MM THICK flooring. Under layer of 38mm thick M20 grade cement concrete mix (with stone chips of size 12.5mm well graded) and top layer of 12mm thick metallic concrete of mix 1:2 (1
METALLIC HARDENER TOPING cement hardner mix with approved quality metallic hardening compound : 2 stone aggregate 6mm nominal size) by volume including cement slurry, rounding off edges,
aluminium strips etc. all complete in line with specifications.(Quoted item rate shall be inclusive of providing glass joint strips) (Cement shall be provided free of Cost as per
TCC)
ACRYLIC DISTEMPER PAINT
2 (INTERNAL WALL FINISH ,CEILING Two or more coats of acrylic distemper of approved brand and manufacture to give an even shade including a priming coat with distemper primer complete complete as per
NTPC Specification.
FINISH)

ACRYLIC EMULSION PAINT OVER Providing and applying two or more coats of acrylic emulsion paint as per IS 5411 of approved brand, shade and manufacture to give smooth, hard, durable & glossy finish
3 2MM THICK POLYMER BASED over a coat of primer over prepared plaster surface as per manufacturers guideline and complete as per NTPC Specification.
WATER RESISTANT PUTTY

4 Designer ceramic tiles 7 mm thick dado with Designer ceramic tiles for Toilet, Pantry / Kitchen areas of size 300mmx450mm

Heavy duty dust pressed ceramic


5
tiles 7 mm thick Heavy duty (grade-5) dust pressed ceramic tiles fo size 300mmx300mm

MIRROR POLISHED VITRIFIED Providing and laying mirror polished vitrified ceramic tiles of size 600x600 from reputed / approved manufacturer, complete including underbed of cement mortar 1:3 minimum
6
CERAMIC TILES 18mm thick underbed for flooring and 12mm thick underbed for dado/skirting with neat cement slurry @3.3Kg/sqm , 3 mm groove joint pointed neatly with 3x4mm stainless
epoxy grout SP-100 of laticrete or approved equivalent etc. all complete for following(Cement shall be provided free of cost for Cement sand mortar only as per TCC)

Providing, fixing and laying light weight mineral fibre tile false ceiling of minimum thickness 15 mm and exposed surface semi-perforated with depth of perforation as 4 mm and
humid resistance of 95% RH and fire performance of class 0/1 as per BS 476 with metal suspension grid system with galvanized Tees of section 24 X 38 mm for main runners of
MINERAL FIBER BOARD FALSE approved colour and make as per specification including 50mm thick mineral wool insulation (density48kg/cum) as per IS:8183 backed with 0.05 mm thick aluminium foil & 24
CELLING GRID PATTERN 600*600 G xfor
25 mm mesh wire netting and shall be fixed to ceiling with 24 G wire ties and suitable fixing arrangements. Additional hangers and height adjustment clips shall be provided
7
return air grills, light fixtures. A.C. ducts etc. suitable M.S. channel (minimum MC 75 @ 1.2m) grid shall also be provided above the false ceiling level for movement of
personnel to facilitate maintenance of lighting fixtures, AC ducts etc. complete with cut-outs etc. The size of tiles shall be 600 X 600 mm Required MS channel shall be
measured & paid extra under respective item unit rate.
Providing, fixing and laying light weight mineral fibre tile false ceiling of minimum thickness 15 mm and exposed surface semi-perforated with depth of perforation as 4 mm and
humid resistance of 95% RH and fire performance of class 0/1 as per BS 476 with metal suspension grid system with galvanized Tees of section 24 X 38 mm for main runners of
MINERAL FIBER BOARD FALSE approved colour and make as per specification including 50mm thick mineral wool insulation (density48kg/cum) as per IS:8183 backed with 0.05 mm thick aluminium foil & 24
CELLING GRID PATTERN 600*600 G xfor
25 mm mesh wire netting and shall be fixed to ceiling with 24 G wire ties and suitable fixing arrangements. Additional hangers and height adjustment clips shall be provided
7
return air grills, light fixtures. A.C. ducts etc. suitable M.S. channel (minimum MC 75 @ 1.2m) grid shall also be provided above the false ceiling level for movement of
personnel to facilitate maintenance of lighting fixtures, AC ducts etc. complete with cut-outs etc. The size of tiles shall be 600 X 600 mm Required MS channel shall be
measured & paid extra under respective item unit rate.

Providing & fixing Acid / Alkali resistant (Chemical resistant) tiles confirming to IS:4457 in flooring/Dado and shall be laid over bitumastic lining of
8
min.12mm thick (to be laid in layers of 6mm each). The tiles shall be applied with 6mm thick Potassium Silicate bedding mortar as per IS:4441, 4443 & 4832,
6mm thick pointing of joints of tiles with acid/alkali resistant epoxt/furane mortar up to a depth of 20mm and bituminastic end sealing and including
preparation of surface, application of bitumen primer, curing etc. all complete as per specification. The tiles should be abrasion resistant & durable.

ACID/ALKALI RESISTANT
9
DADO(WALL) 12 mm thick Acid / Alkali resistant (Chemical resistant) tiles in dado

ACID/ALKALI RESISTANT TILES


10
(FLOOR) 20 mm thick Acid / Alkali resistant (Chemical resistant) tiles in flooring

ACID/ALKALI RESISTANT Providing and applying 2 or more coats of Chlorinated Rubber paint of approved brand and colour to floors, walls and ceiling including preparation of
CHLORINATED RUBBERPAINT FOR surface to receive paint, providing and applying chlorinated rubber zinc phosphate primer confirming to IS 158 complete all as per manufacturer's
BALANCE HEIGHT recommendations and as approved by engineer, at all heights above or below grade level, inclusive of intermediate coat of Titanium dioxide / micaceous iron
oxide complete as per specifications.

Providing and fixing galvanised MS down take pipes conforming to IS: 1239/IS: 3589 of 150 mm dia- Medium quality as per IS:1239(part-I) all complete as per specification.
(Galvanising shall be as per IS: 4736. The minimum mass of zinc coating shall not be less than 400 gms/sq.m. as per IS:6745. The zinc coating shall be smooth and shall be
11
150 DIA GALVANLZED MILD STEEL subjected to testing as per IS: 2633, for uniformity of coating. The zinc coating shall be free from all defects as per IS: 2629. All rain water down comers shall be provided with
roof drain heads and complete with shoes bends, junctions, sockets, adapters, brackets and finished with anticorrosive painting over a coat or primer. Downcomers shall be
RAIN WATER PIPE provided with 45 x 45 cm size Khurras having minimum thickness of 30 mm with M-20 concrete over PVC sheet of 1mx1mx400micron and finished with 12 mm thick cement
sand plaster 1:3.The rainwater down comers shall be provided with suitable C.I. grating at inlet point etc. all complete as specification.(Cement shall beprovided free of Cost as
per TCC)

Providing and laying cement concrete chequered flooring tiles of 22 mm thickness and size 300x300 mm conforming to IS 13801 with 8 mm thick 1:4 cement mortar over the
12
1000 WIDE CHEQUERED TILE PATH top most layer of roofing treatment in pathway or entire area with fine joints including sealing of joints (silicon/elastomeric sealant) and providing expansion gap in both
WAY directions filled up with (silicon/elastomeric) joint sealant, underbed(as per drawings) etc all complete. (Water proofing paid elsewhere)(including cost of cement for tiles
making)(Cement shall be provided free of Cost for mortar only as per TCC)

13 GLASS PARTITION

Providing and laying 18-20mm thick polished Granite stone of approved color and texture in entrance area flooring, entrance steps, Entrance area staircases. Under bed shall
14
18MM THICK POLISHED GRANTE average 30 mm thick of 1 cement : 2 sand : 4 stone aggregate by volume and brought to proper level. The granite stone slabs/tiles laid over under bed, pressed and
STONE tapped down with wooden mallet to the proper level, lifted and pressed again with adhesive chemicals for fine joint preparation and finished with pigments/chemicals of
same colour as granite stone, curing, grinding, granite polishing etc. all complete.(Cement shall be provided free of cost for Cement sand mortar only as per TCC)

Providing and applying high solid content liquid applied Urethane based elastomeric water proofing membrane with one coat of polymerised mastic over the RCC roof to
achieve smooth surface as primer with an application rate of minimum 6 sq.m per litre and two successive liquid coatings of high solids content urethane pre-polymers or
equivalent material based finish coats as per relevant IS/ASTM standards(ASTM C 836 and ASTM C 898), to form an elastomeric membrane with overall dry film thickness 1.5
mm subject to minimum 500 gm/sqm/coat application rate. Item includes surface preparation, polyscrim cloth /fabric, polymerised mortar base preparation, etc all complete
as per specifications and directions of engineer in charge.
15 WATER PROOFING
Providing and applying high solid content liquid applied Urethane based elastomeric water proofing membrane with one coat of polymerised mastic over the RCC roof to
achieve smooth surface as primer with an application rate of minimum 6 sq.m per litre and two successive liquid coatings of high solids content urethane pre-polymers or
equivalent material based finish coats as per relevant IS/ASTM standards(ASTM C 836 and ASTM C 898), to form an elastomeric membrane with overall dry film thickness 1.5
mm subject to minimum 500 gm/sqm/coat application rate. Item includes surface preparation, polyscrim cloth /fabric, polymerised mortar base preparation, etc all complete
as per specifications and directions of engineer in charge.
15 WATER PROOFING

Providing and laying wearing course consisting of 25mm thick plain cement concrete of grade M15 (1:2:4) with graded aggregate of 12.5mm size cast in panels
of maximum size 1.2mx1.2m and reinforced with 0.56 mm dia. galvanised chicken wire mesh and sealing of joints (in grooves of 6mm X 6mm) using silicone
sealent /elastomeric water proofing membrane etc all complete.(Cement shall be provided free of Cost as per TCC)

146.666666667

You might also like