ARUZE

TECHNICAL TRAINING PROGRAM

SHOOT to WIN CRAPS - MAIN UNIT

ATTP DOC CRPS-MS 001 1 / 16 2019 ARUZE GAMING


Table of contents

1. CABINET BASIC KNOWLEDGE ......................... 4


1.1 MAJOR COMPONENTS ......................................... 4
1.2 CABINET VARIATIONS (MAIN UNIT) .................... 4
1.3 PLACEMENT OF DOOR SW. .................................. 5
1.4 DRIVING UNIT .................................................... 6
1.5 DETECTING WIN OF DICE .................................. 7
1.6 DETECTING DICE ERROR .................................... 8
1.7 SPECIAL GAME RULES ........................................ 8
1.7.1 Odds and RTP variations ........................... 8
2. MAINTENANCE LIST........................................... 9
3. MAINTENANCE .................................................. 10
3.1 FIELD GLASS .................................................... 10
3.2 DICE ................................................................. 10
3.3 FIELD ............................................................... 10
3.4 CLEANING INSIDE CABINET .............................. 10
3.5 CHECKING ACTUATOR SCREWS ......................... 11
3.6 REPLACING SPRING ......................................... 11
3.7 PERFORM I/O TEST ........................................... 11
3.8 CONFIRM ERROR METER................................... 11
4. SOFTWARE SETTING FOR NO DICE ............... 12
4.1 ERROR STATUS FOR 'NO DICE' ................. 12
5. LIVE CAMERA SETTING ................................... 12
5.1 THINGS TO BE REQUIRED AND PREPARING ....... 12
5.2 PROCEDURE FOR LIVE CAMERA SETTING .......... 12
6. TROUBLESHOOTING ........................................ 15
6.1 NO DICE ........................................................... 15
6.2 DICE INIT ERROR ........................................ 15
6.3 ACTUATOR ERROR ...................................... 15
6.4 SENSOR TIMEOUT ERROR DICE READ
ERROR SENSOR DATA ERROR SENSOR OPEN
ERROR SENSOR INIT ERROR ............................... 15
7. SPECIFICATIONS ............................................... 16
7.1 DIMENSION, WEIGHT ........................................ 16
7.2 ELECTRICAL SPECIFICATIONS .......................... 16

ATTP DOC CRPS-MS 001 2 / 16 2019 ARUZE GAMING


ATTP DOC CRPS-MS 001 3 / 16 2019 ARUZE GAMING
1. Cabinet basic knowledge
1.1 Major components
1: Tower light
1 2: Top sign
3: 15” LED
4: Pole
2 5: Station unit
3
6: Control spacer
7: Spacer
3

5 3

1: Outer Field Illumination LEDs 7


2: Inner Field Illumination LEDs 4
3: Field area
4: Live camera unit 5
5: LED PCBs
6: field glass 6
7: Spot LEDs

1
4 1: Driver case
2: Transformer Boxes
5
3: Control box
2
4: Woofer
5: Switching HUB

1.2 Cabinet variations (Main Unit)


 Standard cabinet : 8 players
 Separate Main and Station : Yes (need optional parts)
 Extend Station : 50 stations (include basic 8 stations)
 No signage : No
 Option parts : Tower light

ATTP DOC CRPS-MS 001 4 / 16 2019 ARUZE GAMING


1.3 Placement of door sw.

Parallel connection Parallel connection

Station Station
No.4 POLE 3
No.5

FAN 3

1 DSW
3
DSW R3
KE
EA

S
Station Station
2
P
SP

EA
KE
DS
No.3 R No.6
W
5

3
DSW
DSW

FAN 4
POLE 2

POLE 4
1
DSW 1

FAN 2

3
DSW
DS
W2

DS
W
4
Station Station

R
No.2 No.7

KE
SP
EA

EA
K

4
SP
1 ER
DSW 3
2 DSW
FAN 1

Parallel connection POLE 1

Station Station
No.1 No.8

Location. Door Switch Name


DSW 1 No. 1 MAIN DOOR SW
DSW 2 No. 2 MAIN DOOR SW
DSW 3 No. 3 MAIN DOOR SW
DSW 4 No. 1 SECURITY AREA DOOR SW
DSW 5 No. 2 SECURITY AREA DOOR SW

Fan Name
FAN No. 1
FAN No. 2
FAN No. 3
FAN No. 4

ATTP DOC CRPS-MS 001 5 / 16 2019 ARUZE GAMING


1.4 Driving unit
<Structure of field movement>

6 field
F5
5
F4 7
F1
11
3
F2
4 a

F3
Moving shaft
19
12
1

19

13 ASSEMBLE TO BODY
18
14
Tube linear actuator
10 F7

15 10

9
F6

DC24V

USB BD-GM- Digital


AP-7 M2IO Servo
(DL)#2 Driver

AC IN

ATTP DOC CRPS-MS 001 6 / 16 2019 ARUZE GAMING


1.5 Detecting WIN of dice
The dice has 6 RFID in each face below.

RFID with acceleration sensor

RFID antenna

<RFID>
There are 5 types of ID written into the RFID tag.
# NAME Data Format
1 MID 32bit Re-writeable
2 LOT ID 32bit Re-writeable
3 DICE ID 32bit Re-writeable
RNG ID
4 32bit Re-writeable
(Unique ID)
5 CRC32 33bit Re-writeable

RFID antenna reads RFID on bottom side of the dice and detects WIN
number. The doce has number on each side but sum of each parallel
sides are 7. So when the system reads 1 on the bottom, the win
number (surface) is 6.

<Dice reading diagram>

RX RX FSK RX RX FSK ANT


ANT B ANT A OUT ANT B ANT A IN DRIV

AP-7 COM1 IF RX31230 RX31230 RX31230


RFID Antenna
RS-232c -CR00 -CR00 -ER01

DC15V
DC5V

ATTP DOC CRPS-MS 001 7 / 16 2019 ARUZE GAMING


1.6 Detecting dice error <Error due to continuous results>

<Detecting error during mechanical movement> ERROR Cause


CONSECUTIVE SAME Both the 2 dice showed the
START RESULTS OF TWO same spot over 5 times in a
DICE row.
Either of the 2 dice showed
Field moves to Initialize failed CONSECUTIVE SAME
the same spot over 9 times in
home position [DICE INIT ERROR] RESULTS OF A DICE
a row.
CONSECUTIVE NO
RESULT OF ANY SPOTS
A certain spot was not shown
Start vibrating OF A DICE (DICE-A)
by the (color) dice over the
CONSECUTIVE NO
100 times in a row.
RESULT OF ANY SPOTS
OF A DICE (DICE-B)
Launching dice

Moving failed
Slight vibration [ACTUATOR ERROR] 1.7 Special game rules

1.7.1 Odds and RTP variations


Move to home
position
No variation on this game.

Excitation OFF Min RTP = 83.33%


Max RTP = 99.82
Average RTP = 93.79%
Failed to open COM port
Start to read RFID [SENSOR OPEN ERROR]

Detecting Timeout reading RFID


WIN [SENSOR TIMEOUT ERROR]

Invalid data (CRC etc.)


Finish to read all [SENSOR DATA ERROR]
dice

<Detecting error during detecting WIN>


Detecting
WIN

Detect 3 RFID Re-detect RFID 5


twice times

Detect 1 or 2 dice NO DICE

Detect 0 or 4 more DICE READ


dice ERROR

ATTP DOC CRPS-MS 001 8 / 16 2019 ARUZE GAMING


2. Maintenance list

Aruze Technician Operator


Replacement Acceptance Before Before Upon Periodic
Regular check
cycle From factory Aging shipment installation inspection

1 Internal cleaning (M/S) O 3months

2 Dice condition 12months O O O O 3months O (1 month)

3 Dice field condition 12months O O O 3months O (1 month)

4 Actuator fixing screw O O 3months

5 Assist Spring and washers for spring 12months

6 Checking of ERROR and ERROR HISTORY O

7 Live camera image O O

8 Perform I/O test O O

9 Cleaning glass O O O (1 month)

ATTP DOC CRPS-MS 001 9 / 16 2019 ARUZE GAMING


3. Maintenance 3) Remove the Table by unscrewing four F2 shown
below from inside the cabinet.
8

3.1 Field glass


a

Clean every 3 months.


There are many die marks on the glass, so clean with
6
F5

a glass cleaner etc. 5


F4 7
F1
11
3

3.2 Dice 4 a
F2

Clean every 3 months. Replace every 12 months. 19 F3


12
Clean three dice by diluted synthetic detergent. 1

3.3 Field 19

13 ASSEMBLE TO BODY
18
Clean every 3 months. Replace every 12 months. 14

Remove dust and dirt from the field with a vacuum 10 F7

cleaner. 15 10

9
F6

<Removing Field (Field and Side wall)>


1) Remove all the parts shown in the figure below. 3.4 Cleaning inside cabinet
Hea Clean every 3 months.
d Remove the accumulated dust as much as possible.
Dust is removed in the same way in each box.

Trim

Glas
Illumination
& cover

2) Remove the 4 screws at the bottom of the lateral side


of the field unit, and detach the Field Wall.

ATTP DOC CRPS-MS 001 10 / 16 2019 ARUZE GAMING


3.5 Checking actuator screws
Check every 3 months.
Retightening the four F2 and four F4 screws (Red
circles).

3.6 Replacing Spring


Replace every 24 months (Blue circle).
8

6
F5
5
F4 7
F1
11
3
F2
4 a

19 F3
12
1

19

13 ASSEMBLE TO BODY
18
14

10 F7

15 10

9
F6

Spring

Intentionally blank
3.7 Perform I/O test
Perform the OUTPUT TEST on the main unit and
check whether all the LEDs light up properly.

Main unit AUDIT > TEST > OUTPUT TEST

3.8 Confirm error meter


If there are many specific errors, take necessary
actions. For details, refer to Troubleshooting.

Main unit AUDIT > ERROR METERS


Main unit AUDIT > RECALL METERS > ERROR
HISTORY

ATTP DOC CRPS-MS 001 11 / 16 2019 ARUZE GAMING


4. Software setting for no dice 5. Live camera setting
4.1 ERROR STATUS FOR 'NO DICE' If you replaced the camera, follow the steps below to make
settings on the camera side.
MAIN AUDIT > SETTING > GAME SETTING
5.1 Things to be required and preparing
Set if or not a single occurrence of “NO DICE” is regarded
as an error. a. One main unit to which the camera (w/lens) is to be
installed.
NO (Default) b. One station.
“NO DICE LOCKUP INTERVAL” is displayed, and it is c. One Windows PC that installed “Easy Config for FB-
possible to set it. If within 100 consecutive games the H200Np” (Download here(Official page))
“NO DICE condition” (when only two dice or less can d. Two LAN cables (cat 5e or above)
be recognized) is detected the same number of times e. Ethernet hub (100base or faster)
as set on ”NO DICE LOCKUP INTERVAL” (2 to 5), f. Mass produced SSD (Main and Station)
“DICE FAILURE” is displayed and the machine locks.
NOTIS
YES IP address for PC to be used should be “Automated IP
If a “NO DICE” condition (when only two dice or less address acquisition”, “IP address [192 168 201 1]” and
can be recognized) is detected, “NO DICE” is displayed “subnet mask [255 255 255 0]”.
and the machine locks up.
5.2 Procedure for live camera setting
1) Attach the camera to the main unit and connect the
LAN cable and power connector.

2) Connect LAN cable PC to Main unit HUB.

3) Boot up the main unit and PC.

4) Startup Easy Config application on the PC.

5) Click Start button, then select “Simple mode” and right


arrow

6) If the camera connected is shown like as below, select


row No.1 and click the right arrow.

7) Click “Live view” to go to the configuration of the


camera main body.

ATTP DOC CRPS-MS 001 12 / 16 2019 ARUZE GAMING


8) Enter “admin” into the entry boxes if needed. 15) Click “Network Settings” And enter the data as
following and click the “Apply”.
9) The screen is displayed like as follows if the plug-in
has normally been installed and live mages can be
seen.
Mode: Static IP
IP address: 192.168.201.5
Subnet mask: 255.255.255.0
Default Gateway: 192.168.201.1
Primary DNS: 192.168.201.1
Secondary DNS: Blank

16) Click “Camera” and select “Indoor 50Hz” or “Indoor


60Hz” for “Scene Selector” and then click “Active”.
10) Change the language with the Language button as
necessary.

11) Click “Configuration” displayed on the upper right of


the screen below and then, click “Video” that is a sub
item for “▽Camera/Video/Audio”.

17) Click “Edit” to go to the “Scene Setting” screen. And


enter the data as following and click the “Save”.

12) Click the “Stream” tab and enter the data as following
for “Stream 1”.

Video Codec: H.264


Video Resolution: 1280×720
Frame Rate: 60
Bitrate Mode: Constant Bitrate change to “Day Profile”: 2 for 5 (1-300) second(s)
Max Bitrate: 5000
Quality: 3 change to “Night Profile: 1 for 300 (1-300) second(s)
GOP: 0
i-Stream: Enable

13) Scroll down the screen and click the “Apply”.

Click “Multicast” and enter the data as following:

Enable: ☑
Multicast Address: 224.0.5.2 Port 3000

14) Scroll down the screen and click the “Apply”.

ATTP DOC CRPS-MS 001 13 / 16 2019 ARUZE GAMING


18) Click “Day Profile”. And enter the data as following
and click the “Save”.

If the camera image is dark / bright and the number


cannot be seen, please change the setting of the red
square in the figure below.

Intentionally blank

19) Click “x” to close the browser window.

20) Click “x” or “Exit” to close all windows for


“EasyConfig”.

21) Unplug all LAN cables. And turn off the PC.

22) Make adjustments on the main body of the camera


while checking live images displayed on the station.
Adjust the angle of view and the focus using the knob
of the lens part.

23) Connect the station and ensure that images delivered


by the camera can be seen.

24) Adjust the focus by focus ring.

Focus ring

ATTP DOC CRPS-MS 001 14 / 16 2019 ARUZE GAMING


6. Troubleshooting 6.4 SENSOR TIMEOUT ERROR
DICE READ ERROR
6.1 No Dice SENSOR DATA ERROR
SENSOR OPEN ERROR
The standard frequency of occurrence is less than 1/700. If SENSOR INIT ERROR
it is significantly exceeding this, check the following:
# Check point Check
# Check point Check RFID unit and wiring among the RFID unit
1 Replacing dice (Scratch, crack, dirt)
2 Dirty field
3 Antenna setting (The other manuals available)
RFID unit and wiring among the RFID unit
1

6.2 DICE INIT ERROR


# Check point Check
Call the TEST from the AUDIT mode.
1 By selecting “HOME POSITION” and “AUTO”, check
that the dice field normally moves up and down.
Wiring between the servo driver and the actuator

6.3 ACTUATOR ERROR


# Check point Check
Wiring between the servo driver and the actuator

ATTP DOC CRPS-MS 001 15 / 16 2019 ARUZE GAMING


7. Specifications 7.2 Electrical Specifications

Rated voltage Max. current


7.1 Dimension, weight
100-120VAC 50Hz, 60Hz 11.7A
Main Unit
220-240VAC 50Hz, 60Hz 6.8A
Width Depth Height Weight
100-120 VAC 50Hz, 60Hz 5.3A
2,798mm 2,798mm 2,680mm 1,224kg Station
Overall 220-240 VAC 50Hz, 60Hz 4.0A
(8 Stations) (110.2”) (110.2”) (105.5”) (2,698lb)

Main 1,650mm 1,650mm 2,680mm 320kg


Unit (65”) (65”) (105.5”) (705lb)
Editorial History
700mm 693mm 1,005mm 113kg
Station Version # Date Contents
(27.6”) (27.3”) (39.6”) (249lb)
01 Aug 23, 2019 First edition
02 Nov 14, 2019 Terminology unification

2798

2798
(200)

1260
2680
1950
1620
1010

ATTP DOC CRPS-MS 001 16 / 16 2019 ARUZE GAMING