ETG - ARUZE TECHNICAL TRAINING XST - v02

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

ARUZE

TECHNICAL TRAINING PROGRAM

X-STATION (AP-X)

ATTP DOC ROUX-MS 001 1 / 7 2019 ARUZEGAMING


Table of contents

1. X-STATION CABINET BASIC KNOWLEDGE..... 3


1.1 MAJOR COMPONENTS ......................................... 3
1.2 DOORS ON THE X-STATION ................................. 4
2. HARDWARE COMPONENTS ............................... 5
3. MAINTENANCE OF X-STATION ......................... 6
3.1 INTERNAL CLEANING ......................................... 6
3.2 CHECKING GAS SPRING ..................................... 6
3.3 CHECKING DOOR SWITCH ................................... 6
3.4 CHECK THE CALIBRATION .................................. 6
3.5 CHECKING OF ERROR AND ERROR HISTORY 6
4. CLEARING RAM ................................................... 6
4.1 WHAT IS A RAM? ................................................ 6
4.2 RAM CLEAR OF STATION ................................. 6
5. RECALL ON THE STATION ................................. 6
6. SPECIFICATIONS ................................................. 7
6.1 DIMENSION, WEIGHT .......................................... 7
6.2 ELECTRICAL SPECIFICATIONS ............................ 7

ATTP DOC ROUX-MS 001 2 / 7 2019 ARUZEGAMING


1. X-Station cabinet basic knowledge
1.1 Major components

Top door

LCD monitor

Touch screen controller

Gas spring (LR side)

Amp case

EDID Emulator

Sub I/O case

Power supply

Security cage

I/O case

Power switch

ATTP DOC ROUX-MS 001 3 / 7 2019 ARUZEGAMING


1.2 Doors on the X-Station

#1 Top Door

#6 Bill Stacker Door

#5 Body I/O PCB


Door
#4 Security Cage
Door

#3 Bottom Door

#2 Front Door

How to Optical
Outside / Mechanical Main Access Critical Monitoring Open
# Doors open the door Retained
Inside door switch Point Parts during power Alarm
door sensor
off/on

Ticket Printer
1 Outside Top Door Key Yes Yes N/A Yes Yes
Bill Validator

Power Switch
Security Cage Security
2 Outside Front Door Key Yes Yes Yes Yes
Door Cage
Body I/O PCB

Bottom
3 Outside Key Yes No N/A N/A Yes Yes
Door Door
Events

Door
Security Front Door PSD
open History
4 Inside Cage Yes No Security Cage NV Yes Yes
Door +Key RAM

Body I/O Front Door


5 Inside PCB open Yes No Body I/O PCB N/A Yes Yes
Door +Key

Bill Stacker Top Door Bill


6 Inside Yes No Bill Stacker Yes Yes
Door open + key Stacker

ATTP DOC ROUX-MS 001 4 / 7 2019 ARUZEGAMING


2. Hardware components

AX-GAL
Backup
AX-GMEM SSD
SSD

PCI EXPRESS SATA 1 SATA 2


PCI EXPRESS

Memory PCB
Video card

DP1 DP2 DP3 DP4 LAN2 COM-1 COM-2 COM-3 COM-4 USB-0 USB-1 USB-3

US option
DP-AMP

Validator
23” LCD

SUBIO
printer

screen
Ticket

Touch
GAT3

M3IO
HUB

BILL

GM-

AX-
Photo sensor
EDID emulator

AX-XCOM

Key switch
AU option

Door sw.
Speaker x2

Counter
Mech
LED
Station

ATTP DOC ROUX-MS 001 5 / 7 2019 ARUZEGAMING


4. Clearing RAM
3. Maintenance of X-Station
4.1 What is a RAM?
3.1 Internal cleaning
There is a nonvolatile RAM on the GMEM PCB what saves
Clean every 3 months. backup data like game meter, setting information and
Remove the accumulated dust as much as possible. Dust record during power OFF.
is removed in the same way in each area and PCB box.
If there is a problem whose cause cannot be identified, it
may be resolved by erasing the RAM called RAM CLEAR.
3.2 Checking Gas Spring
Check every 3 months. 4.2 RAM CLEAR of Station
If the spring force is too weak to support the door, replace
the gas spring. 1) Turn OFF the power switch.

2) Open the Security door and Top door.


3.3 Checking door switch
3) Keep turn the RESET/AUDIT key switch to RESET.
Check every 3 months.
Confirm that the “door open” does not come out easily by 4) Turn ON the power.
shaking the case.
5) Align the message, operate the key switch shown
below;
3.4 Check the calibration Reset Neutral Audit Neutral
Check every 3 months.
Check if the touch screen is working properly with the
following test.

Station AUDIT > TEST > TOUCH SCREEN TEST

3.5 Checking of ERROR and ERROR


HISTORY 5. Recall on the Station
Check every 3 months. Access on Station Audit > Main Menu > LAST GAME
Station AUDIT > ERROR METERS RECALL, or Main Menu > RECALL METERS
Station AUDIT > RECALL METERS > ERROR HISTORY
History name History
If there are many specific errors, perform necessary LAST GAME RECALL 10
corrections. BILL RECALL 10
TICKET IN 35
TICKET OUT 35
CASHLESS TRANSACTION 100
PROMOTIONAL TRANSACTION 100
HOST BONUS TRANSACTION 100
DOOR HISTORY 35
ERROR HISTORY 50
ALL EVENT HISTORY 100
HAND PAY HISTORY 100
PROGRESSIVE HISTORY 100
RETURN BET 35

ATTP DOC ROUX-MS 001 6 / 7 2019 ARUZEGAMING


6. Specifications
Editorial History
6.1 Dimension, weight Version # Date Contents
01 Sep 20, 2019 First edition
Width Depth Height Weight 02 Nov 15, 2019 Terminology unification
670mm 810mm 972mm 90kg
Station
(26.4”) (31.9”) (38.3”) (198lb)

6.2 Electrical Specifications

Rated voltage Max. current


100-120 VAC 50Hz, 60Hz 4.7A
220-240 VAC 50Hz, 60Hz 3.7A

ATTP DOC ROUX-MS 001 7 / 7 2019 ARUZEGAMING