www.hicop.co.

id
hicop@simed.co.id
Contents
Company Profile ............................................................ 3

Qualification Certificates ................................................ 4

Heating Price Performance Ratio .................................. 5

Air to Water Heat Pump ........................................... 6 - 7

Air to Water With Pump ............................................ 8 - 9

Swimming Pool Heat Pump .................................. 10 - 11

Swimming Pool Portable Series ........................... 12 - 13

All In One Heat Pump .......................................... 14 - 15

High Temperature Heat Pump ............................... 16 - 17

Water to Water Heat.........................................................


Pump 18

Multifunction Titanium Heat Pump ......................... 20 - 21

Dryer Heat Pump .................................................. 22 - 23

Split Type ….......................................................... 24 - 25

Water Chiller ......................................................... 26 - 27

Mini Tank .............................................................. 28 - 29

Commercial Tank ................................................. 30 - 31

Gas Water Heater ........................................................ 32

Project References ............................................... 33 - 39

2
Company Profile
PT. Simed Prakarsa Indonesia has established in 1982 and distribute
water heater of famous brands: Solahart Water Heater, Handal Water
Heater, Raypak Water Heater and HiCOP Heatpump Water Heater.

In 2009, the Company introduced HiCOP also introduced duplex tank


Heatpump water heater to with high quality material.
Indonesia.
In 2018, the company introduced
The Company devotes to specialize Gas Water Heater. This variance is
in distributing energy-eficient heat the beginning for HICOP to join the
pump and hot water unit, mainly for retail market for small appliances
guesthouses, hotels, schools,
offices, factories, hospitals and villas As leader in heat pump water
all over Indonesia, to provide heater, our services included
energy-saving central heating and products design, product
hot water systems solutions, of consultation and after sales
which rate can be 75% or higher. service.

In 2014, HiCOP introduced High We have excellent experience,


Temperature Heat Pump to passionate work force and strong
subsitute boilers for industries. With after sales service which make
High Coefficient of Performance (Hi possible to provide the highest
COP), this unit more efficient and level of service and speedy
environmentally friendly. response to market demand.

Our product go through strict


international regulation test and our
quality control process to ensure
the high standard of quality before
delivery.

3
Qualification Certificates

• Adoping International standard • Declaraion of the strategic • High-tech products certificate • ISO9001 certificate • SGS CE certificate 1 • SGS CE certificate 2
product marking certificate partner with American Copeland

• SGS CE certificate 3 • SGS CE certificate 4 • SGS CE certificate 5 • SGS CE certificate 6 • TUV CE certificate 1 • TUV CE certificate 2

• TUV CE certificate 3 • TUV CE certificate 4 • TUV CE certificate 5 • TUV CE certificate 6 • TUV CE certificate 7 • TUV CE certificate 8

• TUV CE certificate 9 • TUV CE certificate 10 • TUV CE certificate 11 • TUV CE certificate 12 • TUV CE certificate 13 • TUV CE certificate 14

4 4
Heating Price
Performance Ratio
Economic Value Comparison Table

The following drawings are calculated in an electricity bill Heat Pump compared to other water heater system
of 0.11 USD, the actual costs shall be calculated
preferentially based on local unit price Name Safety Equipment Practical Utility
Lasting Life
HiCOP Low power consumtion,
Safe Up to 15 Years
Heat Pump safe, eco-friendly

Be affected by weather
changes, Unstable water
temperature, Need
Solar Heater Relatively 3-8 years
electrical heater back up
Safe
when In raining or cloudy
days

High running cost,


Electric Relatively
3-5 years Fear of electricity
Heater Safe
leakage accidents

May happen gas


Gas Relatively
3-5 years explosion, toxic, not
Heater Safe
allowed to installed indoor

Pressure devices,
Coal boil Relatively
5-8 years pollution, need specialist
Heater Safe
security check annually

Energy/ Required All Year Cost Annual


Calorie of Required Cost
Heating Type Performance Unit Price Energy (10 Ton water Labor Cost Coverage Operation
Energy (Per ton water)
Ratio (per ton water) per day) Cost

Coal Boiler 4000Kcal/kg 40% $0.08/kg 25.10kg $2.32 $7,513 $5,128 20M3 $12,641

Oil Boiler 8429Kcal/kg 80% $0.6/l 6.40 l $3.84 $14,012 $5,128 20M3 $19,141

Liquefied Gas 10800Kcal/kg 73% $0.85/kg 5.30kg $4.48 $16,371 $2,564 10M3 $18,936

Solar Electric
860Kcal/Kwh 85% $0.09/Kwh 51.6Kwh $1.92 $7,026 NO 150m2 $7,026
Heating

Electric Boiler 860Kcal/Kwh 90% $0.09/Kwh 51.6Kwh $4.63 $13,487 NO 10-15M3 $13,487

HiCOP 860Kcal/Kwh 400% $0.09/Kwh 13Kwh $1.17 $4,256 NO 3-10M3 $4,256

- Inlet temperature 150C, Ambient Temperature 200C, Target Temperature 550C

5
Air To Water
Heat Pump

Overview
1. Copeland with R417a or Daikin with
R410a scroll compressor, high efficiency
and stable functions.
2. Emerson ALCO thermal expansion valve,
with accurate and stable throttling
performance.
3. Al-Mg fan motor with Nylon fan blades,
low noise, low power consumption, big air
blow volume.
4. High efficiency Tube in tube heat
exchangers, low fouling and easy for
maintenance.
5. Coated steel or SUS304# stainless steel
case, avoiding rust effectively and
durable.

Features
HIGH COP QUIET RUNNING
Using high technology of heatpump, make the Using efficient, low noise, closed famous brand
HiCOP air to water heatpump COP can reach to 4. compressor and fan, ensure quiet running.

HIGH WATER TEMP 600C EXTREMELY COLD TEMP.


The water temperature arrived at 600C and can be HiCOP Heatpump can work securely and stable
widely applied in preparation for heating and hot under -10 0C extremely cold environment, and
water. normally provide hot water.

6
Working Principle
Construction
Item Description
Compressor Copeland Flexible Scroll
Refrigerant R417a
Expansion Valve Emerson

Cabinet Powder Coated Steel

Water Ingress Protection Rating IPx4

Heat Exchanger Coaxial Coil, Tube in Tube


Controller Multi-Function Digital
Fan Fibre Nylon
Fan Motor Alumunium Magnesium Alloy

Model AW-10 AW-15 AW-21 AW-30 AW-37 AW-42 AW-62 AW-72 AW-90 AW-105

Power Supply 220/1/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50

* Heating Capacity kW 9.5 15 20.8 30 37.5 42 62 72 90 105

* Rated Power Input kW 2.5 3.6 5.2 7.5 9.2 10.5 15 18.5 22,5 27

Water Feed Speed L/H 204 322 430 645 806 938 1330 1548 2063 2257
Max. Current A 19.5 10 15 21 25 28.5 40.5 49 61 73.5

Rared Water Temp O


C 55 55 55 55 55 55 55 55 55 55

Max. Water Temp 60 60 60 60 60 60 60 60 60 60 60

Level against electric shock | | | | | | | | | | |

Net Weight Kg 100 145 165 260 275 295 495 622 670 893

mm 690 x700 870 x830 800 x800 1200 x920 1200 x920 1200 x970 2080 x1100 2200 x1135 2400 x1130 2400 x1300
Net Size
(L*W*H) x 800 x 970 x 1120 x 1220 x 1220 x 1425 x 1676 x 2080 x 2300 x 2080

Required water flow rate m3/h 2.2 3.2 5 6 8 10 12 16 20 24

Required tank cubage 2-3 2-3 3-5 5-8 7-10 18-12 10-15 15-20 20-30 25-30

Water connection G1” G1” G1” G1-1/4” G1-1/4” G1-1/4” G2” G2” G2” G2-1/2”

Operation temp. range O


C -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 -10-45

Noise db(A) < 56 < 56 < 60 < 60 < 60 < 60 < 62 < 64 < 68 < 65

Note :
Heating Outdoor Air temp : 20oC/15oC, Water tank water temperature from 150C heating to 550C.
HiCOP reserves the right to discontinue, or charge at any time, specification or designs without notices and without incurring obligations.

7
Air To Water
With Pump

Overview
HiCOP cycle heating type heat pump hot water heater is the best choice for places where hot water
is in demand such as private house, villas, restaurants, hotels, beauty salons, fitness centers, SPA
and massage centers, public baths, hospitals, dormitories, factories, aquaculture farms, etc. With
outstanding features of high efficient and energy-saving, safe and reliable, environmental-friendly
and comfortable, low operation costs, etc, it' s a direct replacements for traditional hot water devices
like coal, oil and gas boilers.

Unit designed with multi-grade Timing water supply,


antifreeze protection control automatic constants water
function. When outdoor ambient supply, automatic
temperature is lower than setting pressurized water supply.
function.

Automatic heating, automatic


The heat pump utilizes smart
temperature maintaining.
defrosting technology, reduce the
defrosting time and extend the
poll heating time.

Automatic record of the working 500-step liner electronic


mode before recovery of the expansion valve throttle control
recorded working mode after wide adjustable refrigerant flow
power failure. control range.

Featured with block up slopes on


bottom, the chassis is easier to The design is suitable for
drain condensate water. Built-in commercial, industrial,
stainless steel heating belt on agricultural places with large
chassis for condensate anti- hot water demands.
freeze protection.

Unit is designed with electronic


The Heat pump units are with water flow protection, compress
Timing ON/OFF function and two or exhaust temp, protection,
sections can be set at the same compressor high/low pressure
time. protection.

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

8
Wide Working Ambient Temperature Range High Water Outlet Temperature Design

Meet the hot water demand all-year-round in Maximum outlet water temperature can reach 60oC
different places. under - 20oC outdoor without auxiliary electric heater.

Superior Heating Performance In Low Temperature Circulation Pump

High efficient scroll compressor, 25% larger heat This heat pump is complete with circulation
exchange area than ordinary heat pump pump.
products.

Model AWP - 10 AWP - 15 AWP - 21 AWP - 25 AWP -35 AWP - 42

Heating Capacity kw 10.5 15 21 24.5 35 42


Input Power kw 2.59 3.6 5.19 6.76 8.64 10.37
Input Curent A 11.8 5.5 7.9 10.3 13.1 15.8
Rated Output Water L/h 225 300 450 525 600 700
Refrigerant R410A
Power Supply V/ph/Hz 220/1/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Compressor Scroll
Compressor QTY 1 1 1 1 2 2
0
Max. temp. of water output C 60
Fan QTY 1 1 1 1 2 2
Fan Direction Vertical
Water flow volume 3
m /h 2.5 2.5 3.5 4.3 6 7
Water Outlet/Water Inlet inch 1" 1" 1" 1" 1 - 1/4" 1 - 1/4"
Noise dB dB(A) 52 55 55 56 59 62
760/704 860/806 860/806 780/890 1450/730 1450/730
Unit Net Dimension L/M/H
/770 /970 /970 /1182 /1260 /1260
Nett Weight Kg 80 95 120 196 260 280

Note :
Heating Outdoor Air temp : 20oC/15oC, Water tank water temperature from 150C heating to 550C.
HiCOP reserves the right to discontinue, or charge at any time, specification or designs without notices and without incurring obligations.

9
Swimming Pool
Heat Pump

Overview
1. Copeland with R417a or Daikin with R410a
scroll compressor, high efficiency and stable
functions.
2. Emerson ALCO thermal expansion valve,
with accurate and stable throttling
performance.
3. Al-Mg fan motor with Nylon fan blades, low
noise, low power consumption, big air blow
volume.
4. Adopt Titanium Heat Exchanger,
effectively erosion proof and durable.
5. Coated steel or SUS304# stainless steel
case, avoiding rust and durable.

Features
SAFE AND GREEN HIGH COP
HiCOP uses the heat pump technology to heat Using high technology of heatpump, make the HiCOP
swimming pool water, which realize the separation swimming pool heatpump COP can reach to more than
between water electricity. 4.7

Compare with gas heater system, heat pump is HIGH TEMPERATURE 450C
flameless and has no exhaust gas. HiCOP swimming pool heat pump can reach 45 0 C of
temperature, it is applicable for spa.
Compare with electrical heater system, heat pump
is without electricity leakage risk. It is safe and 100% TITANIUM HEAT EXCHANGER
green to use the swimming pool heat pump. Using advanced titanium heat exchanger, greatly resist
erosion of chlorine ion in pool water and durable.

10 8
Working Principle
The principle of heat pump is to pump the low
grade heat from natural air into swimming pool
water with the help of air heat exchanger.

This is how the HiCOP Swimming pool heat


Titanium Conventional
pump heats up Pool Water.
Material

Model SP-39 SP-62 SP-74 SP-117 SP-156


Power Supply (V/ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Heating Capacity (kw) 39 62 74 117 156
Power Input (kw) 7.5 11.3 14.5 20.1 36
Refrigerant R417a/R410a
Max. curent (A) 25 40 50 75 100
Rated water temp (0C) 28 28 28 28 28
Level against electric shock I | I I I
Water-proof grade IPX4 IPX4 IPX4 IPX4 IPX4
Net Weight (kg) 250 465 622 893 1500
Net size (mm)- (L*W*H) 1200x920x1220 2080x1100x1676 2000x1100x1790 2400x1300x2080 2400x1900x2080
Required water flow rate (m 3/h) 15 25 30 45 60
Water Connection (mm) 63 mm 75 mm 75 mm 90 mm 110 mm
Operation temp range (oC) -10-45 -10-45 -10-45 -10-45 -10-45
Noise dB(A) < 60 < 62 < 64 < 68 < 68

Test Condition Ambient temp (DB/WB) : 20 oC/15 o C


Water temp (Iniial Fina:l): 15OC/28 OC

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without
incurring obligations.

11
Swimming Pool
Portable Series

Features
Titanium Coils Exchanger Pressure Protection
Patented Two Titanium Coils With high / low pressure
Heat Exchanger features protection, heat pump are
extended work area with protected at bad working
higher efficiency. condition.

Electric Expansion Valve Water Flow Switch


Smartly adjust the refrigerant The water flow switches
flow rate, the unit are sure to designed HiCOP are with high
work with high efficiency at all sensitivity feature.
time

Ripple Fin Air Exchanger Touch LCD Display


Heat exchanging surface Equipped with LCD touch
extended, heat exchanging Display, this series of pool
effect is improved and the risk heat pumps provides users
of frosting is reduced easy control experience and
provides the unit fine
decorations.

Cost Effective Multiple Model


The COP of this series is as Contains 9 models ranging
high as 5.3 at working from 4kW to 23kW, users can
condition of 24°C/19°C make their favorite choice for a
(DB/WB), which saves you at perfect energy saving
least 80% energy compared swimming.
with traditional electric
swimming pool heating.

12 10
Overview
With complete range of models from 5kW to 23kW,
Portable Series is widely welcomed in global markets. In
the working process of absorbing free heat from the air
and transferring it to water, this series of heat pumps
ensures constant and stable pool water temperature for
you.

Model SPP SPP-5 SPP-8 SPP-11 SPP-17 SPP-23

kW 5.4 8,2 11,3 17 23


Heating Capacity
Btu/h 18360 27880 38420 57800 78200
Heating Power Input kW 1 1,53 2,1 3,48 4,1
COP - 5,4 5,36 5,38 4,89 5,61
Running Current A 4,2 7 9,6 6,8 8
Max Current Input A 6.3 9.2 14.3 9 9.5

Power Supply 220V~/50Hz 380V/3N~/50Hz

Compressor Quantity - 1
Compressor Type - Rotary Scroll
Fan Quantity - 1 2
Fan Power Input W 90 120 150 120x2
Fan Rotate Speed RPM 850
Fan Direction - Horizontal
Noise dB(A) 47 51 54 56 56
Water Connection mm 50
Water Flow Volume m3/h 2,2 3 4,5 6 9
Water Pressure Drop (max) kPa 0,4 0,6 1 2 2,8
Net Weight (L/W/H) kg 35 51 57 98 119

Net Dimensions (L/W/H) mm 746 / 290 / 570 956 / 372 / 600 1115 / 470/870 1002 / 455 / 1250

Heating Outdoor air temp (DB/WB): 240C/190C, Water temp (in) 260C
The data above is only a reference, specific data please refer to the nameplate on the units.
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

13
All In One
Heat Pump

Overview
HiCOP Domestic Heat Pump water heater with a COP
which is 4 times higher than that of the water heater,
this series of water heater is an environmentally
friendly and new designed product special for
providing domestic hot water.

Enameled water storage tank used as the inner


container of the water heater prevents corrosion and
brings better quality water to the user, the coil which is
fixed outside the water tank also avoids being
corroded and its service life will be increased.

Features
1. High COP of 4.0 6. Good Looking Screen
Apply compressors special for heat pump and acquire The screen with elegant looking can be set to orange or
the COP of 4.0. blue background.
2. Long Service Life 7. Wireless Control - iPhone
Coil which is around the unit avoids direct contact with Cell phone can be used as a controller if there is a
the water and corrosion coused by negaive ion, thus relative application installed in it. the most fashionable
the service life would be prolonged. Wi-Fi technology applied in the unit ensures you to
3. Excellent Inner Container check and set the unit whenever and wherever you
Apply enameled water storage tank with high hardness, want.
high temperature and high pressure resistance as the 8. Intelligent Defrosting
inner container which makes the water in the unit Using electromagnetic valve for defrosting makes the
healthier and safer for use. least heat loss of the unit as there is no fluctuation in
4. Thermostatic Expansion Valve water temperature and this also ensures excellent
Applying thermostatic expansion valve as the throttling performance of the unit.
set makes the unit more adjustable in wide working 9. P&T Relief Valve
temperature range and operate more stably and Apply P&T relief valve, which will automatically switch
efficient. on or off depending on the pressure or temperature in
5. Environmentally Friendly Refrigerant the tank, to ensure the safety of the unit.
R134a used as the refrigerant in the unit is pollution-
free and with good heating performance.

14 12
Components

Environmentally
Special Compressor
Friendly
for Heat Pump
Refrigerant

Coil arround Electromagnetic


Heat Exchanger Valve

Enamel Inner P&T


Container Relief Valve

Thermostatic Touch Screen


Expansion Controller
Valve

Wireless Control Micro Channel


(optional) (optional)

Model All In One AI-80 Al-100 Al-200 Al-300 AO-270


Heating Capacity kW 1 1 1.8 1.8 3.4
Water Tank Capacity L 80 100 200 300 270
Power Input kW 0.27 0.27 0.46 0.46 0.94
Running Current A 1.2 1.2 2.0 2.0 3,97
Power Supply 220V~/50Hz
Compressor Rotary
Rated Outlet Water Temp 0C 55
Air Volume m3/h 220 220 350 350 450
Air Pressure Pa 30 40
Duct Diameter mm 150 150 150 150 -
Noise dB(A) 45 45 45 45 52
Water Inlet/Outlet Size Inch 1/2 1/2 3/4 3/4 3/4
*Auxiliary E-Heater kW 1,5
Net Dimensions mm 520x1215 520x1340 560x1732 640x1880 640 x 1955
Shipping Dimensions mm 710x640x1400 710x640x1525 720x720x1930 720x720x1990 720 / 760 / 2040
Net Weight kg 69 73 112 129 120

Measurement conditions :
Instant heating : Ambient temperature 15oC/13oC, Water inlet 15oC, Water Outlet 45oC
Work range : (1) Ambient temperature is-7-40 oC (2) The max temperature of water tank is 60oC
Operating parameters : The range of the operating water temperatures :
9~60oC The range of the operating water pressures : 0.15~0.7 MPa
Note : HiCOP reserves the right to discontinue, or change at anytime, specifications or designs without notices and without incurring obligations.

15
High Temperature
Heat Pump

Overview
This series is presented the high water
temperature up to 800C. With the
concept of Green and Eco Energy.
Suitable for industrial, Commercial and
other necessities.

EVI System Safe and Pollution Free


The units adopt IVI system combining with high- Driven by electricity without danger of
efficient heat exchanger, making the units more burning and explosion and adopting R134a
stable and energy efficient. because of the eco-friendly refrigerant without pollution to
application of these advanced heat pump the environment. thus, the units are safe
technology, the unit are with lower operation cost. and pollution free.

Higher Outlet Water Temperature 800 Reduce CO2 Emissions


The outlet water temperature of the units can Heat Pump reduce million of tons of CO2
reach 800C by circular heating to meet the need emissions from boiler.
for high temperature, but the energy consumption
is just 20% of boiler.

16 16
Model HT-14 HT-26 HT-40 HT-54
Power Supply (V/ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50
(kW) 14 26 40 54
Heating Capacity (BTU) 47768 88712 136480 184248
* Rated Power Input (kW) 4.6 9.2 14 18
* Water Feed Speed (L/h) 185 370 860 741
* Test Condition * Ambient temp (Dry Buld/Wet Bulb):20OC/15OC, Water temp (in/out): 15OC/80OC

Refrigerant R134A

Refrigerant Weight (g) 4400 4400*2 4400*3 4400*4


(type) scroll
compressor (number) 1 2 3 4
(type) Axial flow type with Nylon fan Blade
(discharging) Horizontal
(number) 1 1 2 2
Fan
(air flow)(m3/h) 5000 11000 7400*2 7400*2

Evaporator Aluminium / Cu lamellar tube evaporator

Condenser (heat exchanger) Coaxial coil heat exchanger (Copper Tube-in-Steel Tube)

Economizer (heat exchanger) Stainless Steel Plate


Throttling Device Emerson Thermal Expansion Valve

Controller Indoor Digital Controller

Required Water Flow Rate (m3/h) 4 8 12 16

Water Connection G1” G1-1/4” G2” G2”

Required Tank Cubage (t) 3-5 7-10 12-15 15-20

Max. Current (A) 13 25 37,5 49

Noise dB (A) ≤ 64 ≤ 65 ≤ 68 ≤ 68

Level again electric shock | | | |


Water proof IPX4 IPX4 IPX4 IPX4
Max. Water temp ( C)
O 80 80 80 80
Operation temp. range (OC) -10-45 -10-45 -10-45 -10-45
Net Weight (kg) 270 320 680 680
Net Size-(L*W*H) (mm) 800 x 800 x 1120 1200 x 970 x 1420 2080x1100x1680 2150 x 1135 x 2080

Heating condition : outdoor temperature DB/WB 200C/150C; * outlet water 750C, inlet water (return) 700C.
Note : HiCOP reserves the right to discontinue, or change at any time, speci ications or designs without notices and without incurring obligations.

17
Water to Water
Heat Pump

Overview
HiCOP Water to Water heat pump absorb
heat (energy) from water source and
transfer it to warm and heat the water, for
domestic hot water and heating.
The unit could be installed in indoors, as
floating support for compressor to reduce
vibration at the most extent and noise
insulation inside the cabinet as well as
noise jacket for compressor.

Reliable components used

Copeland scroll compressor Saginomiya brand 4-way valve.

Tube in tube heat exchanger. Emerson brand expansion valve.

Light touch controller. Pressure Gauge.

18 18
Working Principle

The ground loop transfers Increasing the pressure


ground energy to a refrigerant raises the temperature
in the heat pump.
Heat is transfered to the
heating water

Heat is transfered to the room by


radiators or underfloor heating /
Earth or Water Source hot water for bathroom

The refrigerant expands


causing it to cool

Model WW-20 WW-40 WW-60 WW-84 WW-120 WW-160 WW-200

Power Supply V/ph/Hz 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
kW 20.5 42 60 84 120 160 200
Heating Capacity
BTU 68240 143296 204720 286593 426500 614160 682594
Rated power input kW 4.6 9.2 13.8 20 30 36 55
kW 15 30 45 60 90 120 132
Cooling Capacity
BTU 51177 102355 153540 204709 319875 460620 450512
Rated Power Input kW 3.6 7.1 10.8 14.3 21.4 28.5 40
Refrigerant R410A
Compressor Type Scroll
Required Hot Water Flow m3/h 4 8 12 16 20 32 38
Rate
Required Water Source Flow m3/h 3.2 6.4 9.6 12.8 24 25.6 30
Rate
Water connection G1” G1-1/4” G2” G2” G3” G3” G3”
Noise dB(A) ≤ 42 ≤ 44 ≤ 45 ≤ 45 ≤ 50 ≤ 52 ≤ 54
Max. Current A 13 25 37 49 83 98 116
Max. Water Output Temp. O C 60 60 60 60 60 60 60
Water Source Temp. Range O C 5 ~ 35 5 ~ 35 5 ~ 35 5 ~ 35 5 ~ 35 5 ~ 35 5 ~ 35
Net Weight kg 120 250 500 500 750 920 920
Net Size (L/W/H) mm 790x620x850 700x720x1290 1560x840x1380 1560x840x1380 2400x900x1380 2000x1100x1460 2000x1100x1460

Heating by water Source Temp. (In/Out) : 15 OC / 7OC and Water Temp. (In/Out) : 15OC / 55OC ;
Cooling by Water Source Temp. (In/Out) : 25OC / 30OC and Water Temp. (In/Out) : 12OC / 7OC ;

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

19
Multifunction
Titanium
Heat Pump

Overview
✓ Compact air / water heat pump for outside installation.
✓ With suction gas cooled Copeland scroll compressor.
✓ With extensive alumunium /Cu lamellar tube Evaporator and
Titanium tube in tube condenser.
✓ Axial Fan.
✓ Refrigerant cycle with thermostatic expansion valve, filter, gas-
liquid separator, high and low pressure switches.
✓ With efficient automatic defrosting by hot gas principle.
✓ Electric and terminal box. With control and disturbance signaling.
✓ Heating regulator for mounting to the wall.
✓ Filled with refrigerant R417a
Water connections
✓ Water connections have to be done on site.
✓ Heating and condensate connections of flexible pippes with
external thread (R)
Condensate connections
✓ The drain pipeline is to be made with sufficient incline and
without change of the cross.
✓ The water connections and the drain pipelines must be
protected against frost on site.
✓ Shipon on site
Heat source connections (Air
intake or air outlet)
✓ Air intake from the side.
✓ Air outlet from the side
Electrical Connections
✓ Connection from the bottom to the left or to the right.
Installation
✓ Variable and cost-efficient installation possibilities.

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or design without notices and without incurring obligations.

20 20
Model MFT - 20 MFT - 38 MFT - 52

Power supply V/ph/Hz 380/3/50


* Heating Capacity kW 20 38 52
* Rated Power input kW 4.6 9.2 13.8
* Cooling Capacity kW 12.5 25 37
* Rated Power Input kW 4.8 9.5 14

Refrigerant R417A

Max Current (A) 13 25 35

Compressor Scroll
0
Max. Heating water temp C 60

Water-proof grade IPX4

Nett weight Kg 280 580

Nett size mm 900x685x1490 1420x1100x1680 2150x1420x1910


Required Cool water flow rate m3/h 2.5 5 7.5
Required Hot water flow rate m3/h 3 8 12

Water Connection operation G1" G1-1/4" G2"


0
Temp. Range C -55
Noise dB (A) ≤60 ≤62

* Heating by ambient temp.(DB/WB): 70C /60C and water temp. (in/out): 400C /450C
* Cooling by ambient temp.(DB/WB): 350C /240C and water temp. (in/out): 120C /70C
* Heating by ambient temp.(DB/WB): 200C /150C and water temp. (in/out): 150C /550C

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or design without notices and without incurring obligations.

21
Dryer
Heat Pump

Overview
A heat pump dryer is a new type of drying
device which transfers heat energy in the air
into refrigerant to heating or drying. It
successfully applies reverse Carnot principle
by using electric energy to start and make
refrigerant constantly accomplish the
thermodynamic cycle process among
evaporator, compressor, condenser and
expansion valve. Heat pump dryer is very
economical, capable of saving the 50% ~ 70%
energy compared with the classical oven dryer.

Features
Closed Cycle Structure High Energy Saving
Unaffected by Environment No Heat Loss

No Dust Pollution Clean High Drying Quality


and Safe Good Appearance

Convenient to Install Easy to


Maintain

22 22
Working Principle

HiCOP dryer can be used in agriculture product, including fruits, seafoods, medicinal materials, corn, wheat and etc.

Model DR-18 DR-36

Operation Temp. Range 0C 0 - 500C 0 - 500C

Drying Temp. Range 0C 30-750C 30-750C

Heating Capacity kW 18 36

Power Input kW 6 12

Current A 11 22

Electric Heater kW 12.00 24.00

Dehumidification Capacity kg/h 25.00 50.00

Air Outlet Mode Slide-blown

Unit Dimension mm 1830*1150*1313 2120*1330*1550

Advised Chamber Size m3 20-30m3 40-50m3

Testing Conditions : Outdoor temperature (DB/WB) 200C/150C


Indoor temperature (DB/WB) 600C/300C

▪ Traditional Drying Problem

Large Heat Loss | Easily Influenced by Climate | Bad Drying Environment | High Cost

Note : HICOP reserved the right to discontinue, or change at any time, specifications or design without notice and without incurring obligations.

23
Split Type
Heat Pump

Overview

Split heat pump water heater is


designed with one indoor unit and one
outdoor unit. The air exchanger set in
the outdoor unit will greatly enlarge the
heat exchanger square and improve the
COP of the unit, then lower the
operation cost.

Application

24 14
Model STP - 3 STP - 5

Rated Heating Output kW 3.8 5.75

Rated Power Input kW 0.9 1.3

COP W/W 4.18 4.18

Rated Running Current A 3.95 5.98

Max. Running Current A 5.5 7.59

Power Supply V/Ph/Hz 220 ~ 240/1/50

Hot Water Capacity L/h 80 120

Compressor Quantity 1

Compressor Type / Rotary

Fan Quantity / 1

Air Volume m3/h 2400

Air Discharge Type / Horizontal

Water Pressure Drop kPa 30 28

Water Connection Inch 1 1

Noise dB (A) 51 57

Circulation Water Pump / Wil o R S15 / 6

Default Water Temp 0C 55

Suggested Max. Water Temp. 0C 60

Operation Range 0C -7 ~ 45

Condenser / Tube in Shell Heat Exchanger

Evaporator / Φ7mm Finned Heat Exchanger

Defrosting / By 4-way valve

Controller / Multi - Function Controller + LED Display

Refrigerant / R410A

Casing / Environment - Friendly Galvanized Metal

Nett Weight Kg 58 61

Gross Weight Kg 68 71

Nett Dimension (L/W/H) mm 892x342x605

Shipping Dimensions (L/W/H) mm 905x380x755

Testing Condition: Ambient temperature 20/150C Water circulated from 15 to 550C

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

25
Spa Water Chiller

Overview
Suitable for spa and sauna pools, and for places where special aqueous medium such us sea
water, swimming pool water and thermal spring water is used. Safe and reliable use with strong
corrosion resistance ability.

Application Diagram

Patent-Composite Steel Plastic Shell Coil


Heat Exchanger

1. Heat Exchanger Inner Core


2. Temperature Sensing Point
3. Metal Connector
4. Steel Cover Plate
5. Waterway Sealing Gasket
6. Plastic Cover Plate
7. Drainage Port
8. Refrigerant Way Sealing Gasket
9. Steel Shell
10.Plastic Shell
11.Heat Insulation Material (PU)
12.Mounting Brecket

26
Features

High heat exchange efficiency and compact design Independent joint connector, more durable
High efficient internal thread tubes in heat exchanger. Metal material for water inlet/outlet, strong and durable.
Heat transfer coefficient is more than twice of traditional
shell and tube heat exchanger.
Available for special water quality
Efficient to resist different degree of acid-base corrosion,
Skillful seal of refrigerant inlet and outlet to avoid
chloride corrosion and sediment scouring.
water leakage
Temperature-resisting material for sealing element, able to
resist high temperature up to 200oC and low temperature
down to - 20oC. Corrosion resistant and long service life, no easy
blockage on waterside
Engineering plastic is with better corrosion
Filling of heat insulation material to reduce heat leakage resistance and thus longer service life than metal.
Foam materials filled between steel shell and engineering The waterside volume of heat exchanger is more
plastic shell, efficiently reduce heat leakage. No need for than twice than plate heat exchanger and thus more
extra thermal insulation on the outer casing. resistant to filth blockage.

Model SWC - 7 SWC-14

Rate Cooling Capacity KW 6.9 13.8

BTU/H 23600 47100

Rated Input Power ( Cooling ) KW 2.42 4.8

Rated Input Current ( Cooling ) A 11.0 7.4

Power Supply V/PH/Hz 220/1/50 380/3/50

Compressor Scroll

Hydrophilic aluminum foil fin + internal threaded cooper tube


Heat Exchanger
Titanium heat exchanger

Throttle Control Electronic Expansion Valve

Controller LCD display wired controller

Sound Level dB(A) 52 55

Water Oulet/Water Inlet Inch 1.5" 1.5"

Water Flow Volume m3/h 1.19 2.37

Refrigerant Type R410A

Nett Dimension mm 680/790/820 1445/730/795

Note :
(1) Cooling :Outdoor air temp: 35oC/24oC, Outlet water temp: 5oC, lnput water temp:12oC.
(2)Using in ambient temperature: -5oC ~ 43oC.

HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

27
Mini Tank

Material welding of Duplex


✓ Good weldability
✓ TIG-GTAW, Laser and PAW most common
✓ Use filler metal: Avesta LDX 2101® / 22 9 3 NL
✓ Nitrogen additions to shielding / backing gas gives positive effect on strength and
corrosion resistance

✓ Shielding gas (TIG) Ar + 1-3% N2, Ar + 10-30% He + 2% N2, Ar


✓ Backing gas (TIG) 90% N2 + 10% H2, 95% N2 + 5% H2, N2

✓ Use back gas also when repair and welding


✓ Post weld heat treatment not necessary
✓ LDX2101 is suitable for autogenously welding and welding without filler
✓ Welding decreases corrosion resistance! Effect less with good backing gas shielding.
Post weld cleaning is recommended!

Typical chemical composition weight %


Outokumpu EN ASTM Cr Ni Mo N PRE* Rp0.2**

LDX 2101 1.4162 S32101 21.5 1.5 0.3 0.22 26 450*** Lean Duplex

2304 1.4362 S32304 23 4.8 0.3 0.10 26 400 Duplex

2205 1.4462 S32205 22 5.7 3.1 0.17 35 460 Duplex


2507 1.4410 S32750 25 7 4 0.27 43 530 Super Duplex
4507 1.4501 S32760 25.4 6.9 3.8 - 42 530 Super Duplex
4307 1.4307 304L 18.1 8.1 - - 18 200 Austenitic
4404 1.4404 316L 10.1 2.1 - 24 220 Austenitic

4432 1.4432 316L 16.9 10.7 2.6 - 25 220 Austenitic

904L 1.4539 N08904 20 25 4.3 - 34 220 Austenitic


254 SMO 1.4547 S31254 20 18 6.1 0.20 43 300 Super Austenitic

4529 1.4529 N08926 20.5 24.8 6.5 0.20 45 300 Super Austenitic

R*EP= %Cr + 3.3x%Mo + 16x%N


** [MPa] Hot rolled plate, min values at 20oC according to EN 10088
*** Not yet in EN 10088, Rp0.2 according to ASTM A240

28
Duplex - what's that?
• Austenitic 18Cr + 8Ni + (2Mo)

✓ Excellent formability and weldability.


Austenitic
✓ Good resistance to local corrosion. (Nickel-containing)
✓ Sensitive to Stress to Corrosion Cracking.
• Duplex 22Cr + 1.5 - 5 Ni
✓ Combination of austenitic & ferritic structure.
Duplex Duplex
✓ Not sensitive to SCC. (Low-nickel)
✓ Good weldability and machinability.
✓ High mechanical properties.
✓ Low alloy content - price stable.
• Ferritic 20Cr + (2Mo)
✓ No Ni - content - price stable. Ferritic
✓ Not sensitive to SCC. (Non-nickel)
✓ Limited welding and elongation properties.

Normal Capacity TD-300 TD-400 TD-500


Tank Diameter mm 600 650 700

Inner Tank Diameter mm 500 550 600

Tank Height mm 1560 1810 1828


Inner Tank Material Duplex 1.0 mm Duplex 1.5 mm
Heat Insulation High density polyurethane 50 mm
Finishing Outer Skin Bar Silver Painting 0.5 mm
Max. Test Pressure Bar 10
Max Working Pressure 6

Cold Water Inlet G.1"

Hot Water Outlet G.1"

Circulating Hole (red) G.1"

Circulating Hole (blue) G.1"

Sensor Pipe G.1/2"

Drain Water G.3/4"

Mg Anode G.3/4"
Screwed Electric Heater G.1" (3 kw)
Exhaust (up) G.3/4"

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

29
Commercial Tank
Pressurized &
Non Pressurized

Benefit Product Support


1. High energy efficiency 1. Easy maintenance and Installation
2. Patented and Safety product 2. Quality manufacturing standart
3. Applicable for commercial industries like hotel, 3. Free technical consultation & design
villa, hospital and factory 4. High quality installation
4. Suitable for heat pump and gas water heater 5. Large variety of tanks based on needs
complimentary. 6. Warranty: 5 years for non pressurized tanks, 1
5. High density insulation (eliminate heat loss) year for pressurized tank

30 24
Hot Water Storage Tank (Pressurized)
Model
1000 Liter 2000 Liter 3000 Liter 4000 Liter 5000 Liter 6000 Liter 7000 Liter 8000 Liter

Tank Material Stainless Steel SUS 304

Working
4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8
Pressure (bar)

Shell (mm) 3 3 5 3 4 6 3 4 6 4 5 8 4 6 8 5 6 8 5 8 8 5 8 8

Dome (mm) 3 4 6 4 5 8 4 5 8 4 6 8 5 8 8 6 8 10 6 8 10 6 8 10

Tank Weight
(empty) (kg) 400 500 700 600 800 1100 700 900 1200 900 1200 1500 1100 1500 1700 1400 1700 2000 1600 1900 2100 1700 2000 2200

Tank Weight
1.4 1.5 1.7 2.6 2.8 3.1 3.7 3.9 4.2 4.9 5.2 5.5 6.1 6.5 6.7 7.4 7.7 8 8.6 8.9 9.1 9.7 10 10.2
(full) (Mt)

Tank
Diameter 950 1200 1300 1400 1500 1550 1600 1650
(mm) *

Tank Height
2000 2400 2900 3200 3500 3800 4100 4300
(mm) **

Back Up
Heater

Thermostat Optional (Heatpump / Gas Heater / Electric Heater)

Inlet
Diameter 1.5 2 2 2.5 2.5 3 3.5 4
(inch)

Outlet
Diameter 1.5 2 2 2.5 2.5 3 3.5 4
(Inch)

Drain
Diameter 1.5 2 2 2 2 2.5 3 3
(Inch)

Outer Skin Zincallume 0.5

Finishing
Fined Silver Coated
Outer Skin

Heat
High Density Polyurethane 50 mm
Insulation

Accessories Safety Valve, Pressure Gauge, Temperature Gauge, Air Fan, Magnesium Anode

* Without Jacketing
** Height Total
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

Model Hot Water Storage Tank (Non Pressurized)

Capacity 1000 Liter 2000 Liter 3000 Liter 4000 Liter 5000 Liter 6000 Liter 7000 Liter 8000 Liter

Tank Material Stainless S teel SUS 304

Shell (mm) 1.2 3 3 3 4 4 5 5

Dome (mm) 1.2 3 3 4 4 5 6 6

Tank Diameter (mm)* 1100 1200 1300 1400 1500 1550 1600 1700

Tank Height (mm)** 1600 2400 2900 3200 3500 3800 4100 4100

Tank Weight (empty) (kg) 300 500 600 800 1000 1300 1500 1600

Tank Weight (full) (Mt) 1.1 2.5 3.6 4.8 6 6.3 8.5 9.6

Back Up Heater Optional (Heatpump / Gas Heater / Electric Heater)

Thermostat Optional

Inlet Diameter (Inch) 0.75 2 2 2.5 2.5 3 3.5 4

Outlet Diameter (Inch) 0.75 2 2 2.5 2.5 3 3.5 4

Valve Diameter 1” 2” (Customize)

Drain Diameter (Inch) 0.75 2 2 2 2 2.5 3 3

Outer Skin Zincallume 0.5

Finishing Outer Skin Fined Silver Coated


Heat Insullation High Density Polyurethane 50 mm

Accessories Water Level Controller (WLC), Sig ht Glass, Tempe rature Gauge, Magnesium Anode, Flo atless Switch

* Without Jacketing
** Height Total
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

31
Gas Water Heater

Model No. GWH-A6 GWH-A10

Hot water capacity ∆ 250C


6 10
(L/min)
Rated Heat Loud (kW) 12 20

Product size (mm) 445x300x120 590x327x180

Power Supply Apair Of # 1Dry Batteries

N.W./G.W.(kg) 4.9/6.1 9.1/11.1

Material of Heat Exchanger Oxygent Free Cooper

Waste Air Exhaust Flue Duct

Digital Display Yes

Ignition Methode Water Controlled Automatic Ignition

Gas Inlet G 1/2

Pipe Joint Cold Water Inlet G 1/2

Hot Water Inlet G 1/2

NG 2000Pa
Gas Pressure
LPG 2800Pa

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or
designs without notices and without incurring obligations.

Features
• Classic design with three knobs • 20-min timer protection
• Compact size, easy for installations • Anty-dry burning protection
• Flame out protection • High water pressure protection (safety valve)
• Over-heated protection • With temperature display
• Extremely low water pressure start up • Oxygent free cooper heat exchanger

32
Project References
RS Fatmawati - Jakarta Hotel Amaris Season City - Jakarta
JAKARTA ❑ 1 Unit Heat Pump HiCOP AW-21 ❑ 2 Unit Heatpump HiCOP AW-21
Hotel Bunga-bunga - Jakarta
Hotel Shangri la - Jakarta Hotel Merbabu - Jakarta
❑ 12 Unit Heat Pump HiCOP AI-300
❑ 2 Unit Heat Pump HiCOP SPP-23 ❑ 4 unit Heat Pump HiCOP AI-300
Hotel Grand Novena - Jakarta
RSUD Tarakan - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-10
❑ 2 Unit Heat Pump HiCOP AI-300
TANGERANG
My Place SPA - Jakarta Hotel POP BSD - Tangerang
Hotel Amaris Slipi - Jakarta
❑ 4 Unit Heat Pump HiCOP SP-17 ❑ 2 Unit Heatpump HiCOP AW-35
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Fave Puri - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Holiday Inn - Jakarta BANDUNG
❑ 3 Unit Heat Pump HiCOP AW-90
Hotel Gracia SPA - Bandung,
Hotel Haris Yello - Jakarta
Mel's Lodge - Jakarta ❑ 1 Unit Heat Pump HiCOP AW-10
❑ 5 Unit Heat Pump HiCOP AW-105
❑ 3 Unit Heat Pump HiCOP AO-270
Hotel Shangri la - Bandung
Martha Tilaar SPA - Jakarta
Hotel Genteng Ijo Residence - Jakarta ❑ 1 Unit Heat Pump HiCOP AW-21
❑ 2 Unit Heat Pump HiCOP AI-300
❑ 2 Unit Heat Pump HiCOP AW-10
❑ 1 Unit HiCOP Pressure Tank 2000 L Hotel Oasis - Bandung
Hotel Posto Dormire - Jakarta
❑ 1 Unit Heat Pump HiCOP AW-10
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel 21 - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-10 Setiabudi Regency - Bandung
Hotel NEO Puri - Jakarta
❑ 1 Unit HiCOP Pressure Tank 2000 L ❑ 1 Unit Heat Pump HiCOP SP-39
❑ 2 Unit Heat Pump HiCOP AWP-42
❑ 2 Unit SAC Pressure Tank 2000 L
Hotel Neo Kebayoran Icon - Jakarta Gues House 3S Pasteur - Bandung
❑ 2 Unit Heat Pump HiCOP AW-37 ❑ 2 Unit Heat Pump HiCOP AI-300
Heaven SPA - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Norwood - Jakarta Hotel Resort - Bandung
❑ 2 Unit Heat Pump HiCOP SP-17
❑ 2 Unit Heat Pump HiCOP AW-10 ❑ 2 Unit Heat Pump HiCOP AW-10
❑ 2 Unit Heat Pump HICOP MFT-20
U Residence - Jakarta Hotel Onoma - Bandung
Hotel 7 Days - Jakarta
❑ 5 Unit Heat Pump HiCOP AI-200 ❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Royal Olive - Jakarta Waterboom Panghegar - Bandung
RS Atma Jaya - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-37 ❑ 2 Unit Heat Pump HiCOP SP-17
❑ 3 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank
5000 L The Valley Dago - Bandung
Hotel Park 5 - Jakarta
❑ 2 Unit Heat Pump HiCOP SP-39
❑ 3 Unit Heat Pump HiCOP AW-21
Hotel Gunawaman - Jakarta ❑ 3 Unit Heat Pump HiCOP AW-37
❑ 4 Unit Heat Pump HiCOP AW-10
RS Hermina - Jakarta
Hotel NEO - Bandung
❑ 2 Unit HiCOP Pressure Tank 3500L
Hotel Intan - Jakarta ❑ 1 Unit Heat Pump HiCOP AW-10
❑ 3 Unit Heat Pump HiCOP AW-21 ❑ 1 Unit Heat Pump HiCOP AW-21
Amaris Thamrin City - Jakarta
❑ 2 Unit HiCOP Pressure Tank 3000 L
❑ 2 Unit Heat Pump HiCOP AW-40
Hotel Horison - Bandung
Hotel POP - Jakarta ❑ 1 Unit Heat Pump HiCOP AW-21
Hotel Casa Living - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 2 Unit Heat Pump HiCOP AI-300
Eiffel SPA - Bandung
Hotel Fortune - Jakarta ❑ 1 Unit Heat Pump HiCOP SPP-17
Hotel Ozone - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 3 Unit Heat Pump HiCOP AW-21
❑ 4 Unit Heat Pump HiCOP SP-39 Hotel House Sangkuriang - Bandung
❑ 2 Unit HiCOP Pressure Tank 3500 L
❑ 1 Unit Heat Pump HiCOP AW-21
PT. Arnott's Indonesia
Apartment Paviliun - Jakarta
❑ 2 Unit Heat Pump HiCOP HT-58 Villa Ciwaruga - Bandung
❑ 1 Unit Heat Pump HiCOP AI-200
❑ 1 Unit Heat Pump HiCOP AI-300
Kolam Renang Sunter - Jakarta
Hotel Arosa - Jakarta
❑ 1 Unit Heatpump HiCOP SP-62 Hotel Grand Tjokro - Bandung
❑ 3 Unit Heat Pump HiCOP AW-37
❑ 1 Unit Heat Pump HiCOP AWP-42
RS Yarsi - Jakarta
Hotel Best Westin - Jakarta
❑ 3 Unit Heat Pump HiCOP AW-37 Hotel MAJ Collection - Bandung
❑ 3 Unit Heat Pump HiCOP SP-17
❑ 4 Unit HiCOP Pressure Tank 3000 L ❑ 5 Unit Heat Pump HiCOP SP-39
Universitas Mandiri - Jakarta
❑ 4 Unit HiCOP Pressure Tank 2500 L

33
Project References
Hotel Andelir - Bandung Hotel Artotel Haniman - Bali
BANDUNG ❑ 4 Unit Heat Pump HiCOP AW-10 ❑ 4 Unit Heat Pump HiCOP AI-300
❑ 2 Unit Heat Pump HiCOP AW-10
Hotel Art Deco - Bandung
Hotel House Sangkuriang - Bandung ❑ 4 Unit HiCOP Pressure Tank 1000 L
❑ 8 Unit Heat Pump HiCOP AW-21
❑ 4 Unit Heat Pump HiCOP AW-21
Hotel Ungasan Cliftop Resort - Bali
Hotel Dafam - Bandung
RS Halmahera - Bandung ❑ 2 Unit Heat Pump HiCOP AI-200
❑ 3 Unit Heat Pump HiCOP AW-21
❑ 4 Unit Heat Pump HiCOP AW-10
Hotel Rennaisance - Bali
Hotel Nandya - Bandung
RS Edelweiss - Bandung ❑ 2 Unit Heat Pump HiCOP AW-90
❑ 2 Unit Heat Pump HiCOP AI-300
❑ 2 Unit Heat Pump HiCOP AWP-21 ❑ 2 Unit HiCOP Pressure Tank 5500 L
Hotel Pool Karapitan - Bandung
RS Kasih Ibu - Bali
❑ 1 Unit Heat Pump HiCOP AW-10 SURABAYA ❑ 2 Unit Heat Pump HiCOP AW-37
Mekar Wangi Pool - Bandung Hotel Swiss Bell Darmo Centrum -
Hotel Promenade - Bali
❑ 1 Unit Heat Pump HiCOP AW-10 Surabaya
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 1 Unit Heat Pump HiCOP SP-17 ❑ 3 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank 5000 L
Villa Kharisma - Bali
Hotel Nyland - Bandung
❑ 4 Unit Heat Pump HiCOP AI-300
❑ 2 Unit Heat Pump HiCOP AW-21 Hotel Swiss Beli Tunjungan - Surabaya
❑ 2 Unit Heat Pump HiCOP STP-5 ❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Amaris Teuku Umar - Bali
❑ 1 Unit HiCOP TD-500
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 1 Unit HiCOP TD-300 Hotel Kokoan - Surabaya
❑ 2 Unit HiCOP Pressure Tank
❑ 2 Unit Heat Pump HiCOP AW-21
2000 L
Hotel Moscato - Lembang ❑ 2 Unit HiCOP Pressure Tank 2000 L
❑ 4 Unit Heat Pump HiCOP AI-300
Hotel Puri Artha - Bali
Apartment Caspian - Surabaya
❑ 3 Unit Heat Pump HiCOP AI-300
RS H Saleh Budiman - Bandung ❑ 461 Unit Heat Pump HiCOP GWH A-6
❑ 1 Unit Heat Pump HiCOP AW-21 ❑ 78 Unit Heat Pump HiCOP GWH A-10
Hotel Premier Prada - Bali
❑ 2 Unit Heat Pump HiCOP AW-42
Hotel Triple 7 - Pajajaran Hotel Ibis - Surabaya
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 1 Unit Heat Pump HiCOP AW-10 ❑ 2 Unit HiCOP Pressure Tank 4000 L
Hotel Bali Mandira - Bali
Hotel Blackbird- Bandung Hotel Singasari - Surabaya
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 1 Unit Heat Pump HiCOP AW-21 ❑ 1 Unit Heat Pump HiCOP AI-100
Hotel The Kirana Canggu - Bali
UPI - Bandung Hotel Howard Johnson - Surabaya
❑ 3 Unit Heat Pump HiCOP AW-21
❑ 2 Unit Heat Pump HiCOP SP-69 2 Unit HiCOP Pressure Tank 2000 L
Hotel Kuta Puri Bungalow - Bali
PT. Afiat Pharmaceutical - Bandung
❑ 1 Unit Heat Pump HiCOP AI-300
BALI ❑ 2 Unit Heat Pump HiCOP AI-200

Hotel Aloft - Bali Hotel Grand Inna Kuta - Bali


The Groove Sport Station - Bandung
❑ 2 Unit Heat Pump HiCOP AW-30 ❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit Heat Pump HiCOP SP-39
❑ 1 Unit Heat Pump HiCOP AW-72
❑ 2 Unit Heat Pump HiCOP SP-17
Hotel Horison - Bali
❑ 1 Unit Heat Pump HiCOP AW-21 Villa Aster - Bali
Ciwidey Valley Resort - Bandung
❑ 1 Unit Heat Pump HiCOP SPP-11
❑ 4 Unit Heat Pump HiCOP SP-156
Zen SPA - Bali ❑ 2 Unit HiCOP Pressure Tank 2000 L
❑ 2 Unit Heat Pump HiCOP SPP-23
❑ 1 Unit Heat Pump HiCOP MFT-10
❑ 1 Unit Heat Pump HiCOP HT-14
Hotel Gobleg - Bali
Hotel Fairfield - Bali ❑ 1 Unit Heat Pump HiCOP SP-74
Hotel Santika - Bandung
❑ 3 Unit Heat Pump HiCOP AW-50
❑ 2 Unit Heat Pump HiCOP AW-50
❑ 2 Unit HiCOP Pressure Tank 8000 L Hotel Mulia - Bali
❑ 2 Unit HiCOP Pressure Tank 4000 L
❑ 3 Unit Heat Pump HiCOP SP-39
Hotel Sulis - Bali
Hotel POP Pasar Baru - Bandung
❑ 3 Unit Heat Pump HiCOP AW-21 Hotel Ossotel - Bali
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 2 Unit Heat Pump HiCOP AW-39
Svarga Villa - Bali
Super Soccer Prestasi - Bandung
❑ 2 Unit Heat Pump HiCOP AI-200 Dekkande & SPA - Bali
❑ 2 Unit Heat Pump HiCOP SP-62
❑ 1 Unit Heat Pump HiCOP AI-300 ❑ 4 Unit Heat Pump HiCOP AI-300
Eiffel Spa - Bandung
Nusa Dua Convention Center - Bali
❑ 1 Unit Heat Pump HiCOP SPP-17
❑ 2 Unit Heat Pump HiCOP AW-42

34
Project References
Green Villa - Bali RSUD Bogor
BALI ❑ 2 Unit Heat Pump HiCOP STP-7 ❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Duplex Tank TD-500
Hotel Petitenget - Bali
Restaurant Bebek Tepi Sawah - Ciloto
❑ 6 Unit Heat Pump HiCOP AI-300
Amarin Villa - Bali Puncak
❑ 7 Unit Heat Pump HiCOP AI-300 ❑ 1 Unit Heat Pump HiCOP AW-21
Villa Ultimo - Bali
❑ 1 Unit HiCOP Pressure Tank
❑ 1 Unit Heat Pump HiCOP SP-20
Hotel The Hava - Bali 2000 L
❑ 1 Unit Heat Pump HiCOP SP-17
❑ 2 Unit HiCOP Pressure Tank 3500 L
Wisma BPJS - Puncak
RS Provinsi Bali
Hotel Kristana - Bali ❑ 8 Unit Heat Pump HiCOP AI-300
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit Heat Pump HiCOP AW-15
❑ 2 Unit HiCOP Pressure Tank 5000 L
❑ 2 Unit SAC Pressure Tank 2000 L Hotel Fave - Bogor
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Ibis Seminyak - Bali
❑ 3 Unit Heat Pump HiCOP AW-37 BANTEN Hotel Green Forest - Bogor
❑ 2 Unit Heat Pump HiCOP AW-42
Villa The Kama - Bali Mess UPI - Serang
❑ 2 Unit HiCOP Pressure Tank 3000 L
❑ 3 Unit Heat Pump HiCOP AI-300 ❑ 3 Unit Heat Pump HiCOP AW-10
Villa Lody - Cisarua
Villa Canggu - Bali
❑ 1 Unit Heat Pump HiCOP SPP-11
DEPOK ❑ 1 Unit Heat Pump HiCOP SPP-11
❑ 1 Unit Heat Pump HiCOP SWC-7
Universitas Islam Internasional Hotel Salak - Bogor
Indonesia - Depok ❑ 3 Unit Heat Pump HiCOP AW-37
Villa Wanagiri - Bali
❑ 4 Unit Heat Pump HiCOP AWP-42 ❑ 2 Unit HiCOP Pressure Tank
❑ 1 Unit Heat Pump HiCOP SP-39
❑ 4 Unit HiCOP Pressure Tank 2000 L 3000 L
❑ 4 Unit Heat Pump HiCOP SP-74

Villa Batur - Bali BEKASI KARAWANG


❑ 1 Unit Heat Pump HiCOP SPP-8
Hotel Horison - Bekasi Hotel Britz - Karawang
Hotel Shaggrila - Bali ❑ 1 Unit Heat Pump HiCOP AW-21 ❑ 2 Unit Heat Pump HiCOP AW-21
❑ 4 Unit Heat Pump HiCOP AI-200
Hotel Aston Royal - Bekasi Front One Boutique - Karawang
Villa batu Bolong - Bali ❑ 2 Unit Heatpump HiCOP AW-21 ❑ 3 Unit Heat Pump HiCOP AI-300
❑ 2 Unit Heat Pump HiCOP SWC-7
RSUD Cibitung CIKARANG
Villa Amrita - Bali ❑ 3 Unit Heat Pump HiCOP AW-10
❑ 3 Unit Heat Pump HiCOP AI-300 ❑ 2 Unit HiCOP Pressure Tank 2000 L
Hotel Santika - Cikarang
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Kuta - Bali
❑ 1 Unit Heat Pump HiCOP AI-100
BOGOR
RS Omni - Cikarang
❑ 2 Unit Heat Pump HiCOP AI-200
Hotel Sahid Eminence - Ciloto Puncak ❑ 3 Unit Heat Pump HiCOP AW-42
❑ 4 Unit Heat Pump HiCOP AW-62 ❑ 2 Unit HiCOP Pressure Tank 5000 L
Hotel Wana Segara - Bali
❑ 4 Unit Heat Pump HiCOP AW-21 ❑ 3 Unit Heat Pump HiCOP SP-62
❑ 2 Unit Heat Pump HiCOP AWP-42 CIAMIS
Hotel Pengosekan - Bali ❑ 2 Unit HiCOP Pressure Tank 10.000 L
❑ 8 Unit Heat Pump HiCOP AI-300 ❑ 1 Unit HiCOP Pressure Tank 5000 L
RSUD Ciamis
❑ 1 Unit Heat Pump HiCOP STP-7
Hotel Ibis - Bogor
Villa Kedungu - Bali ❑ 2 Unit Heat Pump HiCOP AW-42
❑ 2 Unit Heat Pump HiCOP-AI 300 ❑ 3 Unit Heat Pump HiCOP AW-42
❑ 1 Unit Heat Pump HiCOP AI-200
Hotel Mirah - Bogor GARUT
Hotel Capital - Bali ❑ 1 Unit Heat Pump HiCOP AW-21
❑ 2 Unit Heat Pump HiCOP AW-10 Villa Ranca Bango - Garut
Hotel Pesona Alam (Harris) Cisarua - ❑ 1 Unit Heat Pump HiCOP AW-10
Hotel The Royal Seminyak - Bali Bogor
❑ 1 Unit Heat Pump HiCOP AW-42 ❑ 2 Unit Heat Pump HiCOP AW-10 RPH Farm - Garut
❑ 2 Unit Heat Pump HiCOP AW-20 ❑ 2 Unit Heat Pump HiCOP HT-14
RS Puri Bunda - Bali ❑ 1 Unit Heat Pump HiCOP AW-21
❑ 3 Unit Heat Pump HiCOP AWP-35
❑ 2 Unit HiCOP Pressure Tank 3000 L

35
Project References
CIREBON KEBUMEN SIDOARJO
Hotel Pemuda - Cirebon Hotel Maxsolute - Kebumen Hotel Aston Kahuripan - Sidoarjo
❑ 1 Unit Heat Pump HiCOP AW-21 ❑ 7 Unit Heat Pump HiCOP AI-300 ❑ 3 Unit Heat Pump HiCOP AW-30
❑ 2 Unit HiCOP Pressure Tank 3000 L
Hotel Sultan Raja - Cirebon RSUP Prembun - Kebumen
❑ 2 Unit Heatpump HiCOP AW-35 ❑ 1 Unit Heat Pump HiCOP AW-10
❑ 1 Unit HiCOP Pressure Tank 1000 L
BANYUWANGI
SUKABUMI Hotel El - Banyuwangi
PANGANDARAN ❑ 4 Unit Heat Pump HiCOP AW-21
Hotel Lido - Sukabumi ❑ 4 Unit HiCOP Pressure Tank 2000 L
❑ 2 Unit Heat Pump HiCOP AW-30 RS H.S Budiman - Pangandaran
❑ 1 Unit HiCOP Pressure Tank 2000 L ❑ 1 Unit Heat Pump HiCOP AW-21 Hotel Illira - Bayuwangi
❑ 1 Unit Heat Pump HiCOP AO-270
PURWAKARTA MAJENANG Hotel Exa - Banyuwangi
❑ 1 Unit Heat Pump HiCOP AO-270
Hotel Pesanggrahan - Jatiluhur Hotel Borobudur - Majenang
❑ 2 Unit Heat Pump HiCOP AWP-21 ❑ 1 Unit Heat Pump HiCOP AI-300
Hotel Kokoon - Banyuwangi
❑ 2 Unit HiCOP Pressure Tank 2000 L
❑ 2 Unit HiCOP Pressure Tank 5000 L
SEMARANG
TASIKMALAYA GRESIK
Hotel Wibowo - Semarang
Hotel Fave - Tasikmalaya ❑ 1 Unit Heat Pump HiCOP AI-300
Hotel @HOM - Gresik
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 2 Unit Heat Pump HiCOP AWP-21
SOLO ❑ 2 Unit HiCOP Pressure Tank 1000 L
BELITUNG
Hotel Sala View - Solo Hotel Santika - Gresik
Hotel Bw Inn - Belitung ❑ 2 Unit Heat Pump HiCOP AW-21 ❑ 2 Unit HiCOP Pressure Tank 2000 L
❑ 2 Unit Heat Pump HiCOP AW-42
Hotel Harris & POP - Solo BLITAR
Hotel Bw Suites - Belitung ❑ 2 Unit HiCOP Pressure Tank 1500 L
❑ 2 Unit Heat Pump HiCOP AW-42 ❑ 2 Unit HiCOP Pressure Tank 3500 L
Hotel Puri Perdana - Blitar
❑ 1 Unit Heat Pump HiCOP AI-100
Hotel Swiss Bell - Belitung
❑ 2 Unit Heat Pump HiCOP AW-21
YOGYAKARTA
BOJONEGORO
Hotel Grand Kesya - Yogyakarta
Hotel Aston - Belitung
❑ 3 Unit Heat Pump HiCOP AW-21
❑ 2 Unit Heat Pump HiCOP AW-42 Hotel Aston - Bojonegoro
❑ 3 Unit Heat Pump HiCOP AW-37
Hotel Premier Inn - Yogyakarta
Hotel Max One - Belitung
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit Heat Pump HiCOP AW-21
JEMBER
Hotel Amartya - Yogyakarta
SUMEDANG ❑ 2 Unit Heat Pump HiCOP AW-37 Hotel Dafam Lotus - Jember
❑ 2 Unit Heat Pump HiCOP AW-30
Wisma Kartika Astri - Jatinangor Hotel Amaris - Yogyakarta ❑ 2 Unit HiCOP Pressure Tank 2000 L
❑ 2 Unit Heat Pump HiCOP AW-21 ❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Meotel - Jember
Hotel NEO - Yogyakarta ❑ 2 Unit Heat Pump AW-30
MOJOKERTO ❑ 2 Unit Heat Pump HiCOP AW-42 ❑ 2 Unit HiCOP Pressure Tank 2500 L
Hotel Ayola - Mojokerto
Hotel Mercure Phoenix - Yogyakarta
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit Heat Pump HiCOP AW-42
LAMONGAN
❑ 2 Unit Pressure Tank 3000 L
❑ 2 Unit HiCOP Pressure Tank 1500 L
Hotel Hobet - Lamongan
Mess PT Sengdam ❑ 1 Unit Heat Pump HiCOP AI-100
Hotel Aveon - Yogyakarta
❑ 1 Unit Heat Pump HiCOP AW-10
❑ 2 Unit Heat Pump HiCOP AW-15
❑ 1 Unit SAC Pressure Tank 1000 L
2 Unit HiCOP Pressure Tank 1500 L

36
Project References
Apartment Pertamina - Balikpapan
MALANG ❑ 299 Unit Heat Pump HiCOP AI-100
LOMBOK
Hote Fave - Malang Villa Selong Selo - Lombok
Hotel Four Point - Balikpapan
❑ 2 Unit Heat Pump HiCOP AW-41 ❑ 11 Unit Heat Pump HiCOP STP-3
❑ 3 Unit Heat Pump HiCOP Double Wall
❑ 1 Unit Heat Pump HiCOP SPP-8
AW-39
The Alpines - Malang ❑ 1 Unit Heat Pump HiCOP SPP-11
❑ 3 Unit SAC Pressure Tank 2000 L
❑ 2 Unit Heat Pump HiCOP AW-37 ❑ 1 Unit Heat Pump HiCOP ST-300
❑ 2 Unit HiCOP Pressure Tank 4000 L
BUMA Site LATI - Kalimantan Timur
Hotel Sundancer - Lombok
❑ 7 Unit Heat Pump HiCOP AWP-21
Hotel Whiz - Malang ❑ 2 Unit Heat Pump HiCOP MFT-20
❑ 5 Unit HiCOP Pressure Tank 1500 L
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank 1000 L
❑ 2 Unit HiCOP Pressure Tank 3000 L
MAKASSAR
BUMA Site Indonesia Pratama -
PASURUAN Kalimantan Timur RS Tadjudin - Makassar
❑ 6 Unit Heat Pump HiCOP AWP-21 ❑ 2 Unit Heat Pump HiCOP AW-30
Hotel Horison - Pasuruan ❑ 4 Unit HiCOP Pressure Tank 1500 L ❑ 2 Unit HiCOP Pressure Tank 1000 L
❑ 2 Unit Heat Pump HiCOP AW-37 ❑ 2 Unit HiCOP Pressure Tank 1000 L
Hotel Amaris Pettarani - Makassar
Hotel Baobab Safari - Prigen BUMA Site Binungan - Kalimantan ❑ 2 Unit Heat Pump HiCOP AW-37
❑ 3 Unit Heat Pump HiCOP AW-21 Timur
❑ 2 Unit SAC Pressure Tank 2000 L ❑ 1 Unit Heat Pump HiCOP AWP-21 Hotel Amaris Hertasning - Makassar
❑ 1 Unit HiCOP Pressure Tank 1500 L ❑ 1 Unit Heat Pump HiCOP AW-21
MEDAN RS Samarinda Hotel Kartijasa - Makassar
❑ 1 Unit Heatpump HiCOP AW-21 ❑ 2 Unit Heat Pump HiCOP SPP-23
Hotel Laberzza - Medan
❑ 2 Unit Heat Pump HiCOP AWP-35 BUMA Site LATI Tahap 2 - Kalimantan
❑ 2 Unit HiCOP Pressure Tank 3000 L Timur
MANADO
❑ 4 Unit Heatpump HiCOP AWP-21
Hotel Boulevard - Manado
KALIMANTAN SELATAN ❑ 4 Unit HiCOP Pressure Tank 1500 L
❑ 2 Unit Heat Pump HiCOP AW-10
BUMA Site Sungai Danau Jaya - KALIMANTAN TENGAH
Kalimantan Selatan NUSA TENGGARA TIMUR
❑ 2 Unit Heat Pump HiCOP AWP-21 Hotel Mercure Pangkalan Bun -
❑ 1 Unit HiCOP Pressure Tank 1500 L Kalimantan Tengah Hotel Simphony Alor - Nusa Tenggara
❑ 2 Unit Heat Pump HiCOP AW-33 Timur
RSUD Ulin - Banjarmasin ❑ 10 Unit HiCOP Duplex Tank TD-500 ❑ 8 Unit Heat Pump HiCOP AI-300
❑ 4 Unit Heat Pump HiCOP AW-10

BUKIT TINGGI PALU


KALIMANTAN BARAT
Hotel Santika - Bukit Tinggi Hotel Sultan Raja - Palu
Hotel Swiss Bell Inn - Singkawang ❑ 2 Unit Heat Pump HiCOP AW-30 ❑ 3 Unit Heat Pump HiCOP AI-200
❑ 3 Unit Heat Pump HiCOP AW-37 ❑ 2 Unit HiCOP Pressure Tank 2500 L
❑ 2 Unit HiCOP Pressure Tank 5000 L
PAPUA
Hotel Tapaz Harris - Pontianak LAMPUNG
Hotel M Boutique - Sorong Papua
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 1 Unit Heat Pump HiCOP SP-39
❑ 2 Unit HiCOP Pressure Tank 3000 L Hotel Radison - Lampung
❑ 4 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank 7000 L Kapal Carolia - Sorong Papua
Hotel Premier Inn - Pontianak
❑ 1 Unit Heat Pump HiCOP AO-270
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Aston - Lampung
❑ 2 Unit Heat Pump HiCOP AW-21 Hote M Express - Sorong Papua
KALIMANTAN TIMUR ❑ 1 Unit Heat Pump HiCOP AW-10
Hotel Urban - Lampung
Hotel Swiss bell - Balikpapan ❑ 2 Unit Heat Pump HiCOP AW-10
❑ 2 Unit Heat Pump HiCOP AWP-21

Hotel Quest - Balikpapan JAMBI


❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Swiss Bell - Jambi
❑ 3 Unit Heat Pump HiCOP AW-21
❑ 4 Unit HiCOP Pressure Tank 1000 L

37
Project References

Art Deco Luxury - Bandung Hotel BW Inn - Belitung RS Bali Mandara

Pt. Arnotts - Bekasi Hotel Swiss Bell - Singkawang Hotel Artotel Haniman Ubud - Bali

Hotel Aston - Jakarta Hotel Grand Forest - Bogor Hotel Pasar Baru Square - Bandung

Rsud Cibitung - Bekasi Hotel Grand Inna Kuta - Bali

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

38
Project References

Holiday Express Matraman -Jakarta RS Kasih Ibu - Bali Swimming Pool Upi - Bandung

Aria Graha Pool - Bandung Hotel Sulis - Bali Puri Artha Ubud - Bali

Hotel Radisson - Lampung Hotel Nite & Day - Surabaya Ciwidey Valley Resort - Bandung

Hotel Aston - Bojonegoro Sahid eminence Puncak Ciloto - Cianjur

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

39
Jakarta
(021) 5365 0265

Tangerang
(021) 5471 726

Bandung
(022) 604 6654

Surabaya
(031) 752 0649

Bali
(0361) 238 750

Copyright 2019

COMM/SPI/JUL/2019