Pressure Equalization
Product Name: Element
Product features
1 . S p e c i a l s t r u c t u r a l d e s i g n , r a i n wa t e r c a n n o t d i r e c t l y c o n t a c t t h e
membrane material from any direction, unless the depth of
a c c u mu l a t e d wa t e r a t t h e ve n t i l a t i o n va l ve i s ≥ 4 m m , a n d t h e
wa t e r p r o o f e f f e c t i s b e t t e r t h a n t r a d i t i o n a l p r o d u c t s ;
2 . T h e g a p b e t we e n t h e m a i n b o d y a n d t h e c o ve r s h o u l d b e ≤
0 . 5 mm, wh i c h c a n e f f ec t i ve l y p r e ve n t i n s e c t s , d u s t , a n d o t h e r
s u b s t a n c e s f r o m e n t e r i n g a n d a f f e c ti n g t h e p e r f o r ma n c e o f t h e f i l m
material.
3 . S u i t a b l e m e m b r a n e m a t e r i a l s c a n b e s e l e c te d b a s e d o n t h e
c u s t o me r 's u s a g e e n vi r o n me n t a n d r e q u i r e me n t s t o b e t t e r m e e t
t h e i r e xp e c t e d r e q u i r e me n t s .
Application
1. L i g h t i n g f i xt u r e s
2. S o l a r p h o t o vo l t a i c e q u i p m e n t
3. A u t o m o ti ve c o m p o n e n t s
4. Communication equipment
5. M e d i c a l e q u i pment
6. P r e c i s i o n e l e c t r o n i c e q u i p me n t
Working principle of the product
Hot melt
environmental
Technology welding+ultrasonic ROHS 2.0
requirements
welding
Optional membrane materials and characteristics
Membrane material
Air permeability 10KPa Water pressure resistance characteristic
No.
Oil
SV—P50 ≥1.2L/Min 50KPa/2Min
repellent/hydrophobic
Oil
SV—N1 ≥2L/Min 20KPa/2Min
repellent/hydrophobic
Breathability curve
Pressure (Kpa) 1 2 3 4 5 6 7 8 9 10
air permeability
0.03 0.12 0.25 0.38 0.52 0.69 0.81 0.96 1.09 1.26
(L/Min)
Testing Testing
NO. Testing Testing condition
requency standard
Waterproof Maintain a water depth of 1 meter for 30 Each batch GB/T 4208-
3
performance minutes 2017
low
4 temperature -40℃ Keep 48H Each batch ISO16750.4
storage
high
5 temperature 125℃ Keep 48H Each batch ISO16750.4
storage
T min=-40℃,T max=85℃,The transition time
between two extreme temperatures is within 30
Temperature
6 minutes, maintained for 8 hours at each Each batch ISO16750.4
shock
temperature, cycled 5 times, and observed for
2 hours at room temperature
Apply torque vertically to the product until it Company
8 Torque test Each batch
fractures and deforms standard
Note: The above are standard packaging standards. When the order quantity is less than the
standard packaging quantity, choose the appropriate packaging method based on the actual
quantity;
When customers have special requirements, execute according to customer requirements;