Active Control [LOGO]

Risk analysis ul. Spokojna 6


Upload your logo to
35-112 Rzeszow

"My details"

Heater Controller box

Heating controller for 3 external heating elements

Version: 1

Date: 30-11-2021

Author: Andrzej Rogala

Generated on Tools.Euronorm.net page 1/3


Not OK
Direc- Danger / Risk/Action Risk/Action
tive Code Characteristic Dangerous event Explanation Before Measure After Management measure
Measure Measure
LVD 2 Protection against Measures of a technical nature shall be laid down in accordance with The heating controller has no RCD 45 / The Heating controller must be supplied 1.5 /
hazards arising point 1, in order to ensure that: protection Low risk; attention from a source protected by RCD. Low risk; Temperatures on the surface of the tool should never
from the electrical (a) persons and domestic animals are adequately protected against the required The information must be included in the acceptable cause a danger.
equipment danger of physical injury or other harm which might be caused by direct operation manual. Insulation resistance should be periodically tested.
or indirect contact;
(b) temperatures, arcs or radiation which would cause a danger, are not
produced;
(c) persons, domestic animals and property are adequately protected
against non-electrical dangers caused by the electrical equipment which
are revealed by experience;
(d) the insulation is suitable for foreseeable conditions.

Generated on Tools.Euronorm.net page 2/3


OK
Direc- Danger /
tive Code Characteristic Dangerous event Explanation

LVD 1 General conditions The tool has been designed and manufactured to ensure that protection against the hazards is assured, providing that the
(a) the essential characteristics, the recognition and observance of which will ensure that electrical equipment will be used safely equipment is used in applications for which it was made and is adequately maintained.
and in applications for which it was made, shall be marked on the electrical equipment, or, if this is not possible, on an
accompanying document;
(b) the electrical equipment, together with its component parts, shall be made in such a way as to ensure that it can be safely and
properly assembled and connected;
(c) the electrical equipment shall be so designed and manufactured as to ensure that protection against the hazards set out in
points 2 and 3 is assured, providing that the equipment is used in applications for which it was made and is adequately maintained.
LVD 3 Protection against Technical measures shall be laid down in accordance with point 1, in order to ensure that the electrical equipment: The overload does not endanger persons, domestic animals, and property in foreseeable conditions.
hazards which (a) meets the expected mechanical requirements in such a way that persons, domestic animals and property are not endangered;
may be caused by (b) is resistant to non-mechanical influences in expected environmental conditions, in such a way that persons, domestic animals
external influences and property are not endangered;
on the electrical (c) does not endanger persons, domestic animals and property in foreseeable conditions of overload.
equipment
EMC 1 General Equipment shall be so designed and manufactured, having regard to the state of the art, as to ensure that: Equipment has been designed for industrial immunity and emissions class B.
requirements (a) the electromagnetic disturbance generated does not exceed the level above which radio and telecommunications equipment or
other equipment cannot operate as intended;
(b) it has a level of immunity to the electromagnetic disturbance to be expected in its intended use which allows it to operate without
unacceptable degradation of its intended use.
EMC 2 Specific Installation and intended use of components All installations are installed applying good engineering practices and respecting the information on the intended use of its
requirements for A fixed installation shall be installed applying good engineering practices and respecting the information on the intended use of its components, with a view to meeting the essential requirements.
fixed installations components, with a view to meeting the essential requirements set out in point 1.

Generated on Tools.Euronorm.net page 3/3