PP67-PE-EXT-CT-DOR-DS-Q-063 - Rev01 - Data Sheet PI-TR-942-potable Water Tank

You might also like

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 10

Doc. Ref.

: PP67-PE-PIR-CF-DOR-DS-Q-063
Peru Block 67 Field
Development Revision: 01 Rev Date :13-Jul-2011

Status: IFC Class: 1


DATA SHEET POTABLE WATER
TANK PI-TR-942 Page 1 of 10

DATA SHEET- POTABLE WATER TANK


PI-TR-942

01 IFC Issued for Comments 13-Jul-11 JP.Reussner F.Le Frapper X.Grandiaud

Rev Status Revision Memo Date Written By Checked By Approved By

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
/conversion/tmp/activity_task_scratch/757754187.doc
Doc. Ref.: PP67-PE-PIR-CF-DOR-DS-Q-063
Peru Block 67 Field
Development Revision: 01 Rev Date :13-Jul-2011

Status: IFC Class: 1


DATA SHEET POTABLE WATER
TANK PI-TR-942 Page 2 of 10

ITEM: PI-TR-942 Service:Potable water tank N° OF UNITS: One


1 GENERAL INFORMATION
2 PID ref: PP67-PE-PIR-CF-DOR-PI-H-942
3 Design code: API 12F 12th Edition
4 Internal diameter mm 4 708 (24) Level settings (minimum values)
5 Tank height mm 7 310 (24) Bottom - LALL mm 300
6 Product height mm 5 900 LALL - LAL mm 300
3
7 Storage capacity (LALL-LAHH) m /bbl 92.8/584
8 LAL – LAH m3 82.3
9 Tank type:fixed roof LAH - overflow mm 600
10 Overflow – Top TL mm 200
11

12 DESIGN DATA
13 Design pressure mbarg Full of water Operating pressure range barg ATM
14 Design vacuum mbarg NA Hydrotest pressure mbarg (6)
15 Design metal temperature (min) °C 18 Product height (design) mm 7 310
16 Design metal temperature °C 43 Design liquid specific gravity @ T - 1
17 Operating temperature range °C AMB Inlet pumping rate m³/h 5
18 Outlet pumping rate m³/h 30
19 Wind Design As per code Foundation design By VENDOR
20 Wind speed m/s 19 (11) Foundation construction By CONTRACTOR
21 Wind pressure kg/m² As per code Sour service NO
22 Roof live load (uniform) kg/m² 112 Lethal service NO
23 Corrosion Allowance mm 3 Cyclic service NO
24 Earthquake design See (11) Sand Jet NO
25 Insulation design NO Blast overpressure NO
26

27 OPERATING DATA
28 Density Flowrate Temperature (°C) Pressure (Barg)
29 kg/m³ 3
m /h Minimum Normal Maximum Minimum Normal Maximum

30 INLET 1000 5 18.5 AMB 28 - ATM -


31 OUTLET 1000 30 18.5 AMB 28 - ATM -
32 Viscosity cP 0.4 (at ambient temperatures)
33 Molecular weight g/mol 18
34
35 Corrosive components
36 CO2 % mol - H2O % vol 100

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
/conversion/tmp/activity_task_scratch/757754187.doc
Doc. Ref.: PP67-PE-PIR-CF-DOR-DS-Q-063
Peru Block 67 Field
Development Revision: 01 Rev Date :13-Jul-2011

Status: IFC Class: 1


DATA SHEET POTABLE WATER
TANK PI-TR-942 Page 3 of 10

ITEM: PI-TR-942 Service:Potable water tank N° OF UNITS: One


1 MATERIAL SPECIFICATIONS (REFER TO API 650)
2 Shell A 283M-C Nozzle neck - pipe A106 Gr B
3 Lining Internal coating (9) Nozzle neck - plate A 283M-C
4 Roof A 283M-C Nozzle forged flanges A105
5 Bottom A 283M-C Structural members A36
6 Bottom annulus A 283M-C Structural
7 Reinforcing plates A 283M-C Stiffeners A36
8 Plate flanges A 283M-C Roof structure A36
9 Welded attachments (int / ext) A 283M-C Insul.suppts. A36
10 Bolting studs -external A193 Gr B7 (1) Misc.attach. A36
11 Bolting nuts -external A194 Gr 2H (1) Internals SS 316L
12 Bolting studs - internal A193 B8M Class 2 (1) Heating coil NO
13 Bolting studs - internal A194 Gr 8MA (1) Floating roof seal NO
14 Gaskets (2) Electrical heater NO
15 Anchor bolts (1) Agitator NO
16

17 CONSTRUCTION DETAILS
18 Non Destructive Testing Anchor bolt-no off & size 20 x M16 (7)
19 Radiography (4) Bolt circle diameter 4 780 (7)
20 Ultrasonic (4) External painting Yes, see (9)
21 Magnetic particle (4) Internal coating/lining Yes,see (9)
22 Dye penetrant (4) Pickling & Passivating All stainless steel parts
23 Soapy water (4) Inspection (4)
24 Post weld heat treatment (PWHT) (4)
25 Foundation type Concrete
26 Number Of Shell Courses nb 4 (7) Roof to shell joint Frangible
27 Shell courses thickness-bottom mm 8 (7) External roof type design (7) Fixed roof
28 Shell courses thickness mm 8 (7) Angle of the cone 15°
29 Shell courses thickness mm 6.35 (7) Internal floating roof type NA
30 Shell courses thickness mm 6.35 (7)
31 Shell courses thickness mm NA
32 Shell courses thickness mm NA
33 Top girder thickness mm NA
34 Bottom thickness mm 8 (7) Test water supplied by VENDOR
35 Bottom slope (up to bottom drain) - YES, 1 % Insulation NO
36 Bottom annular plate width mm 150 (7) Insulation thickness NA
37 Bottom annular plate thickness mm 21 (7) Fireproofing NO
38 Roof thickness mm 6.35 (7) Fireproofing thickness NA
39 Weight-Full of water kg 141 000 (7)

40 Empty weight kg 10 000 (7)

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
/conversion/tmp/activity_task_scratch/757754187.doc
Doc. Ref.: PP67-PE-PIR-CF-DOR-DS-Q-063
Peru Block 67 Field
Development Revision: 01 Rev Date :13-Jul-2011

Status: IFC Class: 1


DATA SHEET POTABLE WATER
TANK PI-TR-942 Page 4 of 10

ITEM: PI-TR-942 Service:Potable water tank N° OF UNITS: One


1 APPURTENANCES
2 shell stairway YES hand grips and ladder rung YES
3 shell ladder NO earthing lugs (8)
4 rolling ladder NO internal cathodic protection NO
5 internal ladder YES external cathodic protection lug YES
6 roof platform YES free vent YES (3)
7 shell platform YES pressure / vacuum vent NO
8 roof walkway YES emergency vent NO
9 peripheral roof handrailing YES flame arrestors NO
10 flush clean-out door YES blanketing system NO
11 draw off sump YES (16) fire fighting foam system NO
12 scaffold cable support NO water spray system NO
13 heating coil surface (m²) NA Heat detector NO
14 heating coil design pressure/temp NA level gauge NO
15 ladder platform clips NO instruments YES
16 insulation rings or clips NO goose neck & bird screen YES
17 piping clips NO nameplate (shell) SS 316L (8)
18 internal dip pipe for nozzle NO davit On Flush door (8)
19 disch. with vortex breaker NO supports for platforms and stairway YES
20 Lifting trunions / lugs NO

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
/conversion/tmp/activity_task_scratch/757754187.doc
Doc. Ref.: PP67-PE-PIR-CF-DOR-DS-Q-063
Peru Block 67 Field
Development Revision: 01 Rev Date :13-Jul-2011

Status: IFC Class: 1


DATA SHEET POTABLE WATER
TANK PI-TR-942 Page 5 of 10

ITEM: PI-TR-942 Service:Potable water tank N° OF UNITS: One


Nozzle table (18)(19)(21)(22)

NOZZLE TABLE
N O ZZLE N E C K FLA N G E S R E IN F.
MARK D E S IG N A TIO N
D IA M E TE R TH IC K . /C . LIN E N O M IN A L D I. TY P E C LA S . FA C E TH K . x W ID E
D D rain NPS 2 8.74 2600 NPS 2 WN 150 RF 10 x100
LT1 Level transm itter NPS 3 11.13 2600 NPS 3 WN 150 RF 10 x100
S V ent w ith arrestor NPS 2 8.74 200 NPS 2 WN 150 RF
A1 From filters NPS 2 8.74 2600 NPS 2 WN 150 RF 12 x200
B2 O verflow NPS 3 11.13 2600 NPS 3 WN 150 RF 12 x130
B1 O utlet to pum ps NPS 4 11.13 2600 NPS 4 WN 150 RF 10 x80
M Flush clean door 24x36 N P S 36 15.88 2600 N P S 36 WN 150 RF 8 x120
LT3 Level transm itter NPS 3 11.13 2600 NPS 3 WN 150 RF 10 x100
G G auging hatch NPS 8 12.7 200 NPS 8 WN 150 RF 10 x100
G1 Level gauge NPS 3 11.13 2600 NPS 2 WN 150 RF 10 x100
G2 Level gauge NPS 3 11.13 2600 NPS 2 WN 150 RF 10 x100

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
/conversion/tmp/activity_task_scratch/757754187.doc
Doc. Ref.: PP67-PE-PIR-CF-DOR-DS-Q-063
Peru Block 67 Field
Development Revision: 01 Rev Date :13-Jul-2011

Status: IFC Class: 1


DATA SHEET POTABLE WATER
TANK PI-TR-942 Page 6 of 10

Elevation view (14)(17)(20)(23)

30.13
7835
S
ID 400 30.13
Thk 6.35 7675
G
7310
Thk 6.35 WL HLL
7000
6750 B2 G2
ID 4711
Thk 6.35 WL

ID 4711
Thk 6.35

4500
WL
8038.6

ID 4708
Thk 8

2250
B O LT CIRCLE 4780 WL

FLA T HE A D
O .D. 4708
Thk 6.2 ID 4708
Thk 8 460
M
RE F 0.00
300
ID 4624 LT3 B1 A1
Thk 8 -20
A NC
200
20 B O LTS DIA 16 G1 LT1
O FF A X IS
150
D

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
/conversion/tmp/activity_task_scratch/757754187.doc
Doc. Ref.: PP67-PE-PIR-CF-DOR-DS-Q-063
Peru Block 67 Field
Development Revision: 01 Rev Date :13-Jul-2011

Status: IFC Class: 1


DATA SHEET POTABLE WATER
TANK PI-TR-942 Page 7 of 10

Nozzles Eccentration table (17)

Location
Tag

Loc. Ori. Inc. Ecc.


(mm) (°) (°) (mm)
S 7,835.0 90.00 0.00 400.00
G 7,675.0 90.00 0.00 1,000.00

Platform Definition.(23)

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
/conversion/tmp/activity_task_scratch/757754187.doc
Doc. Ref.: PP67-PE-PIR-CF-DOR-DS-Q-063
Peru Block 67 Field
Development Revision: 01 Rev Date :13-Jul-2011

Status: IFC Class: 1


DATA SHEET POTABLE WATER
TANK PI-TR-942 Page 8 of 10

NOTES:
(1) External bolting to be zinc plated / bichromate treated
(2) Non CAF flat gaskets, 2mm thick up to 14” and 3mm above or Spiral wound 316L PTFE filler 4mm thick, 3.2mm thick 316L SS winding internal and
external centering rings per ASME B16.20
(3) Piping to safe location by OTHERS. VENDOR to supply flame arrestor.
(4) As per code
(5) All internals shall be removable through the manholes
Minimum thickness of internals to be defined by VENDOR
(6) Full of water or as per VENDOR's Standard. The most stringent shall apply.
(7) To be indicated / calculated / confirmed by VENDOR
(8) As per relevant standard in PP67-PE-GEN-00-DOR-DW-Q-030 Standards drawings for accessories and equipment of vessels
(9) As per PP67-PE-GEN-00-DOR-SP-R-001 “Painting Specification “
(10) NA
(11) Tank must be designed to withstand the design conditions during operation specified in PP67-PE-GEN-00-DOR-SP-O-100 “Equipment Design
Conditions”

Accelerations (g) Transportation Operating (earthquake)


Vertical NA See note
Horizontal NA 0.29 g, See note
EARTHQUAKE Note:See §5.1.8.of PP67-PE-GEN-00-DOR-SP-I-101
BLAST None

(12) Refer to PP67-PE-GEN-00-DOR-SP-O-100 “Equipment Design Conditions”


(13) NA
(14) Tank provided with a bottom drain to avoid accumulation at the tank bottom
(15) Nozzles shall be able to withstand loads as per PP67-PE-GEN-00-DOR-DW-Q-030 Standards drawings for accessories and equipment of vessels
(16) Shall be located sufficiently far away from the product inlet and outlet nozzles
(17) : Nozzle location and orientation to be confirmed.

(18) : With a blind, VENDOR shall supply gasket and bolting

(19) : NA

(20) – Circumferential seams and weld lines when indicated on tank sketches are only for information and remain on VENDOR responsibility.

(21) : Reinforcement : the given figures are only for information and remain on VENDOR responsibility.

All given thicknesses are indicative only, subject to calculation verification by VENDOR. Thickness of pad reinforcement shall not exceed 1.5*shell or head

thickness for local load reinforcement purpose.

THICK : Thickness, mm

(22) : /C.LINE : for a nozzle located on the head, this figure is the length from the face of the nozzle to the TL, mm

(23) : Access plat-forms and stairs shall be supported by the tank, size and location to be confirmed BY VENDOR.

Welded gussets for the supporting steel shall be provided accordingly.

VENDOR to check the local loads on tank induced by platforms and stairs.

Starting point for stairs is 220°.

Assumed weight of the platforms and stairs, (3 000 kg) is not included within actual weights, but used for Foundation loads calculations.

(24) : Tank dimensions are based on a 750 bbls standard potable water tank, i.e 15 ft-6 in diameter and 24 ft height.

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
/conversion/tmp/activity_task_scratch/757754187.doc
Doc. Ref.: PP67-PE-PIR-CF-DOR-DS-Q-063
Peru Block 67 Field
Development Revision: 01 Rev Date :13-Jul-2011

Status: IFC Class: 1


DATA SHEET POTABLE WATER
TANK PI-TR-942 Page 9 of 10

Summary of Foundation Loads (To be confirmed by VENDOR)

Vertical load Shearing load Bending Moment


case
(daN) (daN) (daN.m)
(1) 136,932 316 1,390
normal wind
(2) 140,270 316 1,390
Operation
(1) 82,159 316 1,390
extreme wind
(2) 84,162 316 1,390
Lifting (2) 9,977 280 1,165
Erection (2) 12,951 316 1,390
1st (1) 140,616 0 0
compartment (2) 143,954 0 0
2nd (1) / / /
Test
compartment (2) / / /
3rd (1) / / /
compartment (2) / / /
(1) 136,932 316 1,390
normal wind
Shut- (2) 140,270 316 1,390
down (1) 82,159 316 1,390
extreme wind
(2) 84,162 316 1,390
(1) / / /
earthquake
(2) / / /
earthquake (1) 157,891 31,469 159,976
Operation
(+) (2) 161,812 32,345 164,368
(1) 115,974 31,469 159,976
earthquake (-)
(2) 118,728 32,345 164,368
(1) / / /
earthquake
(2) / / /
Shut- earthquake (1) 157,891 31,469 159,976
down (+) (2) 161,812 32,345 164,368
(1) 115,974 31,469 159,976
earthquake (-)
(2) 118,728 32,345 164,368
(1) corroded vessel weight (+) with seismic load downside
(2) non-corroded vessel weight (-) with seismic load upside

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
/conversion/tmp/activity_task_scratch/757754187.doc
Doc. Ref.: PP67-PE-PIR-CF-DOR-DS-Q-063
Peru Block 67 Field
Development Revision: 01 Rev Date :13-Jul-2011

Status: IFC Class: 1


DATA SHEET POTABLE WATER
TANK PI-TR-942 Page 10 of 10

Nozzles orientations (17)


N O Z Z LE O R IE N T A T IO N 270
S C A L E = 1 /6 5

180 N 0

90

M 180

160
B1
150
A1

130
120
L T1 110
L T3 90
G1
D

G
S E C TIO N B E TW E E N E L =0 A N D E L = 2 0 0 9 .6

N O Z Z LE O R IE N T A T IO N
270
S C A L E = 1 /5 2 .5

180 N 0

90

110
90
G2
B2
S E C TIO N B E TW E E N E L =6 0 2 8 .9 A N D E L =8 0 3 8 .6

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
/conversion/tmp/activity_task_scratch/757754187.doc