TEST REPORT NO FMTL/TR/CUBE/22-23/34048 Date : 23/01/2023

NAME & ADDRESS OF CUSTOMER PROJECT / SITE ADDRESS


Big city Projects Pvt Ltd Emerald Developers
G-1, Marigold, Almeda Road, Nil Compound,
Opp. Nitin Co. Behind Humera Park,
Panchpakhadi, Triveni Nagar,
Thane West - 400602 Rani Sati Marg, Pathanwadi,
Malad E Mumbai -400097

QUANTITY : 3 Nos.
CONDITION OF SAMPLE : Satisfactory
TEST METHOD FOLLOWED IF ANY : IS 516:1959
SAMPLE RECEIVED DATE 19/01/2023
CONCRETE CUBE TESTING RESULTS
Cube Size (mm) : 150x150x150 Date of Casting : 16/01/2023
Grade of concrete M 50 Date of Testing : 23/01/2023

AGE of Dimension of Specimen Cross- Crushing


SR. (mm) Weight, Maximum
ID Mark of Specimen Specimen Sectional Strength,
NO. (GMS) Load, (KN)
(Days) Length Width Height Area, mm² N/mm²

1 150 150 150 22500 8651 509.2 22.63


2 Footing C-9-9A 7 150 150 150 22500 8538 548.8 24.39
3 150 150 150 22500 8100 651.1 28.94
Average Value = 25.32

Remarks:
1) As per IS 456:2009 (Reaff: 2010) clause no 15.4, the individual variation should not more than ± 15% of the
average. If more, the test results of the sample are invalid.
2) Acceptance criteria of compressive strength is given in IS 456:2008 (Reaff: 2010) Inclause No 16.1

NOTE:
-- Test Results related only to the samples tested. Details of the concrete sample are provided by the client.
-- The reported result/s is/are valid only to the sample submitted to the laboratory.
-- This certificate may not be reproduced in part without the permission of this Laboratory.
-- Only duplicate report will be provided by the laboratory on the request.
-- We do not take any responsibility of any involvement in any type of litigation arising results
submitted by F. m. Testing Lab.
For F.M. Testing Lab

Authorised Signatory

**********END OF REPORT**********