Technical data: ZT 22VSD-10 IMD

Product definition
Model ZT 22VSD
Pressure variant 10 bar
Integrated dryer IMD dryer
Frequency 50 Hz

Reference conditions
Absolute inlet pressure 1 bar(a)
Relative humidity 0%
Air inlet temperature 20 °C
Cooling air inlet temperature 20 °C
Effective working pressure 7 bar(g)
Motor shaft speed(rpm) 4570 rpm

Performance data*1
Maximum working pressure 9.5 bar(g)
Free air delivery ( at maximum volume flow rate ) 47.4 l/s
− Total electrical power input 27.6 kW
− Total specific energy requirements (SER) 582.4 J/l
Free air delivery ( at minimum volume flow rate ) 25.6 l/s
− Total electrical power input 16.9 kW
− Total specific energy requirements (SER) 660.9 J/l
Effective working pressure 7 bar(g)
Free air delivery ( at maximum volume flow rate ) 56.3 l/s
− Total electrical power input 29.1 kW
− Total specific energy requirements (SER) 517.1 J/l
Free air delivery ( at minimum volume flow rate ) 26.2 l/s
− Total electrical power input 13.5 kW
− Total specific energy requirements (SER) 517.5 J/l
Minimum effective working pressure 4 bar(g)
Free air delivery ( at maximum volume flow rate ) 57.2 l/s
− Total electrical power input 24.5 kW
− Total specific energy requirements (SER) 427.8 J/l
Free air delivery ( at minimum volume flow rate ) 27.1 l/s
− Total electrical power input 10.9 kW
− Total specific energy requirements (SER) 403 J/l
Integrated dryer data
Integrated dryer data IMD50
Typical pressure dew point Remark: Depending on
operating conditions. Please consult Atlas Copco for -5 - -40 °C
more details.

Unit data*3
Mean sound pressure level*2 69 dB(A)
Cooling air flow compressor 2.2 m³/s

Cooling air flow motor 0.12 m³/s

Cooling air flow frequency converter 0.14 m³/s


Cooling air flow dryer 0.81 m³/s
Oil capacity 23 l

Dimension and Weight


Unit dimensions Shipping dimensions Shipping dimensions
with pallet only with wooden crate
Length 2195 mm 2420 mm 2420 mm
Width 1016 mm 1200 mm 1200 mm
Height 1621 mm 1760 mm 1830 mm
Volume 3.62 m³ 5.11 m³ 5.31 m³
Net weight 1341 kg 1397 kg 1436 kg

Limitations
Maximum effective working pressure 9.5 bar(g)
Minimum effective working pressure 4 bar(g)
Maximum ambient temperature 40 °C
Minimum ambient temperature 0 °C
Maximum cooling air temperature 40 °C
Minimum cooling air temperature 0 °C
Maximum altitude (above sea level) 1000 m

Installation connections
Compressed air outlet G1 1/2" F
Condensate drain connections DO 8 mm/ DI 5,5 mm
Electrical cable entry size M63x1,5 F
Main drive motor
Motor manufacturer Siemens
Motor nominal power 22 kW
Motor service factor 1.2
Motor efficiency class dedicated VSD motor
IES2
Power drive system efficiency*4
motor nominal efficiency 92.7 %
Motor protection class IP54

Frequency Converter
Converter manufacturer SIEMENS SINAMICS

Electrical data
Supply voltage 400 V
Supply frequency 50 Hz
Package current*5 47.1 A
Electrical network TT or TN network

Main feeder circuit protection


(Customer’s installation) *6
Main fuse type gL/gG
Maximum main fuse size 90A
Main control panel short-circuit current rating 10 kA

Approvals
Electrical approval IEC
Pressure vessel approval CE / ASME

Notes
*1 The FAD figures quoted correspond to 'Actual Volume Flow Rate' in accordance with ISO 1217
Ed. 4 (2009), guaranteed with a tolerance of +/-5 % for FAD < 250 l/s (530 cfm) or +/-4 % for FAD >
250 l/s (530 cfm).

*1 The SER figures quoted are in accordance with ISO 1217 Ed. 4 (2009),
guaranteed with a tolerance of +/-6 % for FAD < 250 l/s (530 cfm) or +/-5 % for FAD > 250 l/s (530
cfm).
*2 A-weighted emission sound pressure level at the work station (LpWSAd).
Measured according to ISO 2151: 2008 using ISO 9614-2 (sound intensity scanning method).
The added correction factor (+/- 3 dB(A)) is the total uncertainty value (KpAd) conform with the test
code.
For air cooled machines, sound pressure levels are stated with ducting of outlet cooling air
according the installation proposal

*3 Unit data is valid at reference conditions

*4 The inverter and motor together comply with the requirements for power drive efficiency
(according to IEC 61800-9-2 & EN 50598)

*5 Package current is the current a compressor uses


- at reference ambient conditions
- at 100 % load
- at max pressure
- at nominal voltage
- right before service interval (including fouled filters, etc).

*6 The pre-described fuses OR circuit breaker are maximum main fuses or circuit breaker to protect
the installed compressor electrical panel.
Cable and fuse or circuit breaker selection will depend on customer’s installation.
Fuses or circuit breaker of the same type/class are mandatory. Not installing these fuses or circuit
breaker will void warranty in case of an electrical failure.
Installing smaller fuses might lead to smaller supply cables. If Main circuit breaker shown as NA (not
applicable), only fuses are allowed.

The information in this document is subject to change without prior notice.