1SDH000721R0507

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Doc. N.° 1SDH000721R0507 - ECN000254658 - Rev.

SACE Tmax XT

1SDH000721R0507

Sganciatori Ekip G Dip LS/I, Ekip M Dip LIU, Ekip M-I XT2-XT4
Release Ekip G Dip LS/I, Ekip M Dip LIU, Ekip M-I XT2-XT4
Auslöser Ekip G Dip LS/I, Ekip M Dip LIU, Ekip M-I XT2-XT4
Dèclencheur Ekip G Dip LS/I, Ekip M Dip LIU, Ekip M-I XT2-XT4
Relé Ekip G Dip LS/I, Ekip M Dip LIU, Ekip M-I XT2-XT4
电子脱扣器Ekip G Dip LS/I, Ekip M Dip LIU, Ekip M-I XT2-XT4

XT2-XT4

XT2 XT4
1

1 XT2-XT4

2
1
2 Ekip G Dip LS/I - XT2-XT4 III/IV - IEC ONLY

LED Color CONDITION Run time


Green LED ON (fixed) = Device active
L Red LED Fixed = L pre alarm (0,9 * I1 < I < 1,2 * I1) LED Blinking = L alarm (I > 1,2 * I1)
S Red LED Blinking = S alarm (I > I2)
LED Blinking = Parameters inconsistency - L = S or L = I.
L|S |I Red
LED Blinking without Parameters inconsistency = generic fault (please contact ABB)

1 Ekip G Dip LS/I

Default setting
Default-Einstellung
Configuration par défauit
Esempio: Ajuste de default
Example: 默认设置
In = 100 A
I1= 100 x (0,4+0,08+0,32)= 80A
t1= 6 s @240 A (3I 1) 2
Esempio: In=100 A
Example: I2 =100 x (1,5+2)=350A
t2= 0,2 s @ In>I2

t
t L
L

t1

S
I

t2

I1 I3 I I1 I2
I

SACE Tmax | ABB


3 Ekip M Dip LIU - XT2-XT4 III - IEC/UL

LED Color CONDITION Run time

Green LED ON (fixed) = Device active


L Red LED Fixed = L pre alarm (0,9 * I1 < I < 1,2 * I1) LED Blinking = L alarm (I > 1,2 * I1)
U Red LED Blinking = U alarm
LED Blinking = Parameters inconsistency - L = I.
L | U | I Red
LED Blinking without Parameters inconsistency = generic fault (please contact ABB)

1 Default setting
Default-Einstellung
Configuration par défauit
Ajuste de default
默认设置
Esempio:
Example:
In = 100 A
I1= 100 x (0,4+0,08+0,32)= 80A
CLASS = 3E@(7,2xI1)=2s<ti<3s@576A(7,2Ax80) Esempio:
Example:
In=100 A
Ekip M Dip LIU I3 =100 x (6+1+2)=900A
t
L
t
L

CLASS
U
CLASS
I U

I1 I3 I 2

I1 I3 I
t
L

CLASS
3E 2s<ti£3s U

5E 3s<ti£5s @ (7,2 x I1) t6 I

10E 5s<ti£10s
20E 10s<ti£20s I6 I1 I3 I
U = ON

I6=
t6 = 2s
{ min (L1, L2, L3) < 0,1In
and
max (L1, L2, L3) > 0,5I1

4 Ekip M-I - XT2-XT4 III - IEC ONLY

Default setting
LED Color CONDITION Run time Default-Einstellung
Configuration par défauit
Green Ajuste de default
LED ON (fixed) = Device active
默认设置

Esempio: t
Example:

In = 100 A I
I3= 100 x (6+2)= 800A

1 I3 I

SACE Tmax | ABB


5 XT2-XT4

1
PROCEDURA DI CONTROLLO DIAGNOSTIC PROCEED DIAGISTIKABLAUF PROCÉDURE DE DIAGNOSTIC PROCEDIMIENTO DIAGNOSTICO 自诊断流程
- CONTROLLO LED: - UNIT CHECK LED: - EINEITHSPRUF-LED: - UNIT CHECK LED : toutes les - LED CONTROL UNIDAD: todos los - 脱扣器功能指示灯:
tutti i led del relè si all the leds in the relay Alle LEDs des Relais müssen diodes du relais doivent led del relé se deben 各功能指示灯依次闪烁
devono accendere must come on aufleuchten s'allumer encender
- ULTIMA INDICAZIONE DI TRIP: - LAST TRIP INDICATION: - ANGABE DER LETZTEN AUSLOSUNG: - LAST TRIP INDICATION : - INDICACION ULTIMA ACTUACION: - 前次脱扣指示
se presente nella memoria if present in the relay's Wenn im Speicher des Relais si présente dans la mémoire si está presente en la memoria 如果在脱扣器内有存储
del relè data store vorhanden. du relais del relé
- LED: resta acceso finchè - LED: remains on for - LED: Bleibt angeschaltet, - LED: la DIODE reste - LED: queda encendido - LED指示灯: TT连接
l’unità TT e’ connessa al relè as long as the TT is bis die Einheit TT an die Relais allumée tant que l'unité TT mientras la unidad TT 到脱扣器后保持常亮
connected to the relay angeschlossen ist. est connectée au relais permanezca conectada con el relé
- PRONTO PER TRIP - READY TO TRIP - AUSLOSEBEREIT - READY TO TRIP - LISTO PARA LA ACTUACION - 诊断就绪

LED Ekip TT
Verde Rosso
Green Red
Grün Rot
Vert Rouge
Verde Rojo
绿 红
Dispositivo acceso Sostituire batterie
Device ON Change battery
Einrichtung eingeschaltet Batterie ersetzen
Dispositif allumé Remplacer batteries
Dispositivo encendido Sustituir baterías
设备运行 更换电池
2