132 kV 2000 A

Aluminium bus I
Provision for future extension
DS 31.5 kA

BUS CVT
132KV 110V 110V
3 3 3
100 VA; Cl 3P DS 31.5 kA
100 VA; Cl 0.2
DS 31.5 kA DS 31.5 kA 145 kV, 1250 A
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
DS 31.5 kA

DS 31.5 kA

DS 31.5 kA DS 31.5 kA
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
132 kV 2000 A
Aluminium bus II
DS/ES 31.5 kA

BUS CVT
DS/ES 31.5 kA

DS/ES 31.5 kA

132KV 110V 110V


3 3 3
100 VA; Cl 3P
100 VA; Cl 0.2
145 kV, 1250 A
CB SF6 31.5 kA DS/ES 31.5 kA DS/ES 31.5 kA
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
87B
CB SF6 31.5 kA Bus Protection CB SF6 31.5 kA CB SF6 31.5 kA
600-300/1A

CB SF6 31.5 kA
145 kV, 1250 A Protection 50 BF 67/67N 145 kV, 1250 A 145 kV, 1250 A
145 kV, 1250 A
CT

Measuring W Fi kWh A
DS 31.5 kA

DS/ES 31.5 kA Spare V DS/ES 31.5 kA DS/ES 31.5 kA


145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
DS 31.5 kA DS/ES 31.5 kA DS 31.5 kA DS 31.5 kA
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
To Bus CVT
Trans. Protection 87T 25 Trans. Protection 87T 25 Line Protection 21 79 98 25 Line Protection
CT 600-300/1A

CT 600-300/1A

CT 600-300/1A

CT 600-300/1A
Trans. Protection 50 BF 67/67N Trans. Protection 50 BF 67/67N Backup Protection 50 BF 67/67 N Backup Protection All Protection
Measuring Measuring n measuring
W Fi kWh A W Fi kWh A Measuring W Fi kWh A Measuring
system as
Spare Spare mentioned in
V V Spare V Spare
Bus Protection Bus Protection left side
87B 87B Bus Protection 87B Bus Protection
LA 120kV 10 kA LA 120kV 10 kA LA 120kV 10 kA LA 120kV 10 kA
132 kV BCT 100/1 132 kV BCT 100/1 CVT
CVT 132KV 110V 110V
132KV 110V 110V 3 3 3
3 3 3 100 VA; Cl 3P
100 VA; Cl 0.2
100 VA; Cl 3P
64 64 100 VA; Cl 0.2
Outdoor Transformer Outdoor Transformer
87T 87T
132/33 kV 1620 MVA 132/33 kV 1620 MVA
To 132 kV substation
with OTC 17 taps with OTC 17 taps
LA 30kV 10 kA

LA 30kV 10 kA

50/51N 50/51N
33 kV BCT 400/1 33 kV BCT 400/1 at Chapartola
3x1x300 sq. mm 3x1x300 sq. mm
36 kV cu XLPE 36 kV cu XLPE
cable cable
33 kV 200-400/1 33 kV 200-400/1 98 FAULT LOCATOR
Trans. Protection 50/50N 67/67N Trans. Protection
Measuring W Fi kWh A Measuring
V HIGH IMPEDANCE RESTRICTED
87N EARTH FAULT RELAY
VCB 36 kV VCB 36 kV
PT 200 VA; Cl 3P/0.2 1250A 25kA 1250A 25kA PT 200 VA; Cl 3P/0.2
87T TRANSFORMER DEFERENTIAL RELAY
2 3 2 3
33KV 110V 110V 33KV 110V 110V
3 3 3 1 3 3 3 1
Fu se Fu se
87B BUS DEFERENTIAL RELAY
TRANSFORMER DRY TRANSFORMER DRY 81 FREQUENCY RELAY
VCB 36 kV VCB 36 kV VCB 36 kV VCB 36 kV VCB 36 kV VCB 36 kV
33/0.4 KV 100 KVA 1250A 25kA 1250A 25kA 1250A 25kA 1250A 25kA 1250A 25kA 1250A 25kA
33/0.4 KV 100 KVA
(IN CABINET) (IN CABINET) 79 AUTO RECLOSE RELAY
CT 100-200/1 CT 100-200/1 CT 100-200/1 CT 100-200/1 CT 100-200/1 CT 100-200/1 CT 100-200/1
Trans. Protection 50/50N 67/67N Trans. Protection 50/50N 67/67N Trans. Protection 50/50N 67/67N Trans. Protection 50/50N 67/67N Trans. Protection 50/50N 67/67N Trans. Protection 50/50N 67/67N Trans. Protection 50/50N 67/67N 67/67N DIRECTIONAL O/C GROUND RELAY
Measuring W Fi kWh A Measuring W Fi kWh A Measuring W Fi kWh A Measuring W Fi kWh A Measuring W Fi kWh A Measuring W Fi kWh A Measuring W Fi kWh A
V V V V V V V
59 OVER VOLTAGE RELAY
Spare LA 30kV 10 kA PT 200 VA; Cl 3P/0.2
LA 30kV 10 kA PT 200 VA; Cl 3P/0.2
LA 30kV 10 kA PT 200 VA; Cl 3P/0.2
LA 30kV 10 kA PT 200 VA; Cl 3P/0.2
Spare 51/51N O/C & GROUND FAULT RELAY
33KV 110V 110V 33KV 110V 110V 33KV 110V 110V 33KV 110V 110V
Feeder for local Feeder for local
3 3 3 3 3 3 3 3 3 3 3 3
50BF BREAKER FAILURE RELAY
33 kV distribution 33 kV distribution
From From 25 SYNCHRO-CHECK RELAY
BGSHPP BGSHPP
From Budhi From Budhi 21 DISTANCE RELAY
Ganga 20 MW Ganga 20 MW
Var REACTIVE POWER METER
A AMMETER
V VOLT METER
312 core 95 sq. mm 1.1 kV cu XLPE cable 312 core 95 sq. mm 1.1 kV cu XLPE cable
W WATT METER
Var REACTIVE POWER METER
Wh ENERGY METER
DS DISCONNECTING SWITCH
CB CIRCUIT BREAKER
400 V distribution
switch gear panels
LA LIGHTNING ARRESTOR
MCCB Bus sectionizer MCCB
200 A MCCS 200 A 200 A CT CURRENT TRANSFORMER
CVT CAPACITIVE VOLTAGE TRANSFORMER
400 V Bus system 400 V Bus system
VT VOLTAGE TRANSFORMER
WT WAVE TRAP/COUPLING CAPACITOR
MCCBs MCCBs
For self consumption For self consumption
of substation of substation
SLD BUDIGANGA 132 kV SS
5064033-DCW-BHP-BSS-001
132 kV double circuit
For future
151
Service road Service road Symbol Transformer I & II
25000
BATTERY
ROOM
AC/DC
ROOM
REST
ROOM
STORE ROOM Spa re 3
Lightning Arrester (LA)
K ITC HEN
WORKSH OP ROOM
Transformer I & II
Spa re 1
BGSHP1
132/33 kV Disconnecting Switch (DS)
33 kV switchgear

BGHP1
WC
BATH Sta tion
Service road

Tren-er 1
Tra n-er 1
PLCC ROOM
Link
Circuit Breaker (CB)
TYPICAL Bus
coupler
7.0
CONTROL
PLCC ROOM
Tra n-er 2
PLAN OF 2. 08
Sta tion
Post Insulator (PI)
Tren-er 1
ROOM
2. 18
CONTROL
23. 64
BGHP2
OFFICE

3.0
ROOM

BGSHP2
BUILDING Spa re 2
2.0
Current Transformer CT

DS
4. 26
Spa re 4

DS CB CT DS LA
2.0
4.0
Service road Potential Transformer (PT)
4.0
4.0
Transformer I & II

BUS II
2.5
2.5
105

3.0
t

Service road
DS
3.0
Space for future extension

3.0 t

DS
3.0
2.5 t

BUS I
2.5
t
Service road

3.0 3.0 2.5 3.0 3.0


4.0 t

DS CT CB DS
4.0
t
2.0

DS
2.0
3.0 t

LA CT
3.0
Transformer I & II
Service road Service road
132 kV double circuit
with BEAR ACSR
To Chapartola/Pahalwanpur
132 kV double circuit
For Future 132 kV grid substation
LAYOUT FOR BUDHI GANGA 132 kV SS
5064033-DCW-BHP-BSS-003
132 kV double bus
out door switchyard
For future provision
98 FAULT LOCATOR
HIGH IMPEDANCE RESTRICTED
87N EARTH FAULT RELAY
87T TRANSFORMER DEFERENTIAL RELAY
87B BUS DEFERENTIAL RELAY
81 FREQUENCY RELAY
79 AUTO RECLOSE RELAY
Outdoor Transformer 67/67N DIRECTIONAL O/C GROUND RELAY
132/33 kV 1620 MVA To 132 kV sub- station For future For future 59 OVER VOLTAGE RELAY
at Chapartola
51/51N O/C & GROUND FAULT RELAY
50BF BREAKER FAILURE RELAY
25 SYNCHRO-CHECK RELAY
33 kV section bus
indoor switch gear 21 DISTANCE RELAY
panels Var REACTIVE POWER METER
A AMMETER
Station Station transformer V VOLT METER
X-mer 33/0.4 kV 100 kVA
33/0.4 kV W WATT METER
100 kVA Var REACTIVE POWER METER
Spare Spare Wh ENERGY METER
BGSHPP BGSHPP DS DISCONNECTING SWITCH
CB CIRCUIT BREAKER
Budhi Budhi
Ganga Ganga LA LIGHTNING ARRESTOR
CT CURRENT TRANSFORMER
CVT CAPACITIVE VOLTAGE TRANSFORMER
VT VOLTAGE TRANSFORMER
400 V distribution
MCCB
200 A
Bus sectionizer
MCCS 200 A
MCCB
200 A
switch gear panels WT WAVE TRAP/COUPLING CAPACITOR
400 V Bus system 400 V Bus system
MCCBs MCCBs
For self consumption For self consumption
of substation of substation
PROTECTION SCHEME FOR BUDHI GANGA
132kV SS
5064033-DCW-BHP-BSS-002
To Pahalwanpur
132 kV grid substation
132 kV double circuit
with BEAR ACSR
170
Chapar Tola substation
Symbol Transformer I & II
Service road Service road Lightning Arrester (LA)
25000

132/33 kV Disconnecting Switch (DS)


Transformer I & II
Fire Wall
BATTERY AC/DC REST STORE ROOM
2. 35
Space for
33 kV switchgear

ROOM Tran-er
11 kV switchgear

ROOM ROOM
K ITC HEN
WORKSH OP ROOM
Feeder 1
Feeder2
future Circuit Breaker (CB)
Service road

Feeder3
Spa re 1
Extension
Spa re 2 HEP
WC Tran-er
BATH
TYPICAL Sta tion
Tren-er 1
33/11 kV 7.0 Post Insulator (PI)
CONTROL
PLCC ROOM
Link
PLAN OF 2. 08
Local
ROOM
2. 18
CONTROL
33/11 kV
OFFICE

3.0
ROOM

BUILDING 2.0
Current Transformer CT
4. 26

DS CB CT DS LA
2.0

Space for future extension


4.0
Potential Transformer (PT)
Service road
4.0
4.0
Transformer I & II

BUS II
2.6
2.6
105

3.0 t

Service road

DS
3.0
Space for future extension

3.0 t

DS
3.0
2.6
t

BUS I
2.6
t
Service road

2.5 3.0 3.0 2.5 3.0 3.0


t
t
t
Transformer I & II
Service road Service road
For Future
For Future 132 kV double circuit
132 kV double circuit To Budhi Ganga SS
132 kV double circuit
with BEAR ACSR
132/33/11 kV SUBSTATION LAYOUT AT
CHAPARTOLA
5064033-DCW-BHP-BSS-006
132 kV double bus
out door switchyard
For future provision
132 kV bus I
132 kV bus II
For future provision

Outdoor X-mer
132/33 kV
To 132 kV substation To 132 kV Grid sub- For future For future
8/10 MVA
at Budhi Ganga station at Pahalwanpur
Outdoor X-mer
33/11 kV 6/8 MVA
PT 200 VA; Cl 3P/0.2
33KV 110V 110V
3 3 3 PT 200 VA; Cl 3P/0.2
2 3 11KV 110V 110V 2 3
1
33 kV Bus system 3 3 3
1
11 kV Bus system
Fuse
Fuse
400 V Bus system
for self-consumption of X-mer in For local distribution
substation panel 33/0.4 For local distribution Future Use
Future Use
kV 100 kVA
400/230 Distribution panel
36 kV indoor switch gear panels 12 kV indoor switch gear panels
CHAPARTOLA SUBSTATION SLD
5064033-DCW-BHP-BSS-005
132 kV 2000 A
Aluminium bus I
Provision for future extension
DS 31.5 kA

BUS CVT
1 32KV 1 10V 110V
3 3 3
1 00 VA; Cl 3P DS 31.5 kA DS 31.5 kA DS 31.5 kA
1 00 VA; Cl 0.2
DS 31.5 kA DS 31.5 kA 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
DS 31.5 kA DS 31.5 kA DS 31.5 kA DS 31.5 kA DS 31.5 kA DS 31.5 kA
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
132 kV 2000 A
Aluminium bus II
BUS CVT
1 32KV 1 10V 110V
3 3 3
1 00 VA; Cl 3P
1 00 VA; Cl 0.2
DS/ES 31.5 kA
145 kV, 1250 A
DS/ES 31.5 kA DS/ES 31.5 kA CB SF6 31.5 kA DS/ES 31.5 kA DS/ES 31.5 kA DS/ES 31.5 kA DS/ES 31.5 kA
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
CB SF6 31.5 kA 87B
CB SF6 31.5 kA Bus Protection CB SF6 31.5 kA CB SF6 31.5 kA CB SF6 31.5 kA CB SF6 31.5 kA
600-300/1A

145 kV, 3150 A 145 kV, 1250 A Protection 50 BF 67/67N 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
CT

Measuring W Fi kWh A
DS/ES 31.5 kA DS/ES 31.5 kA DS/ES 31.5 kA DS/ES 31.5 kA DS/ES 31.5 kA
Spare V
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
DS 31.5 kA DS 31.5 kA DS/ES 31.5 kA DS 31.5 kA DS 31.5 kA DS 31.5 kA DS 31.5 kA
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
145 kV, 1250 A To Bus CVT
Trans. Protection 87T 25 Trans. Protection 87T 25 Line Protection 21 79 98 25 Line Protection Line Protection Line Protection
CT 600-300/1A

CT 600-300/1A

CT 600-300/1A

CT 600-300/1A

CT 600-300/1A

CT 600-300/1A

Trans. Protection 50 BF 67/67N Trans. Protection 50 BF 67/67N Backup Protection 50 BF 67/67 N Backup Protection All Protection Backup Protection All Protection Backup Protection All Protection
Measuring Measuring n measuring n measuring n measuring
W Fi kWh A W Fi kWh A Measuring W Fi kWh A Measuring Measuring Measuring
system as system as system as
Spare Spare
V V Spare V Spare mentioned in Spare mentioned in Spare mentioned in
Bus Protection Bus Protection left side left side left side
87B 87B Bus Protection 87B Bus Protection Bus Protection Bus Protection
LA 120kV 10 kA LA 120kV 10 kA LA 120kV 10 kA LA 120kV 10 kA LA 120kV 10 kA LA 120kV 10 kA
132 kV BCT 100/1 132 kV BCT 50/1 CVT CVT CVT
CVT 1 32KV 1 10V 110V 1 32KV 1 10V 110V 1 32KV 1 10V 110V
1 32KV 1 10V 110V 3 3 3 3 3 3 3 3 3
3 3 3 1 00 VA; Cl 3P 1 00 VA; Cl 3P 1 00 VA; Cl 3P
1 00 VA; Cl 0.2 1 00 VA; Cl 0.2 1 00 VA; Cl 0.2
1 00 VA; Cl 3P
64 64 1 00 VA; Cl 0.2
Outdoor Transformer Outdoor Transformer
132/33 kV .../... MVA 87T 132/33 kV 8/10 MVA 87T
with OLTC 17 taps
50/51N
with OLTC 17 taps
50/51N
To 132 kV substation To 132 kV Grid
33 kV BCT 400/1 33 kV BCT 200/1 at Budhi Ganga sub-station at Pahalwanpur 98 FAULT LOCATOR
LA 30kV 10 kA LA 30kV 10 kA
HIGH IMPEDANCE RESTRICTED
87N EARTH FAULT RELAY
87T TRANSFORMER DEFERENTIAL RELAY
3x1x300 sq. mm 3x1x300 sq. mm
36 kV cu XLPE 36 kV cu XLPE
cable cable 87B BUS DEFERENTIAL RELAY
33 kV 200-400/1
Trans. Protection
33 kV 200-400/1
Trans. Protection
81 FREQUENCY RELAY
Measuring Measuring
79 AUTO RECLOSE RELAY
VCB 36 kV VCB 12 kV
PT 200 VA; Cl 3P/0.2 1250A 25kA PT 200 VA; Cl 3P/0.2 850A 25kA 67/67N DIRECTIONAL O/C GROUND RELAY
33KV 110V 110V 2 3 11KV 110V 110V 2 3
3 3 3 3 3 3
1 1
Fu se Fu se
59 OVER VOLTAGE RELAY
51/51N O/C & GROUND FAULT RELAY
TRANSFORMER DRY
33/0.4 KV 100 KVA
(IN CABINET)
VCB 36 kV
1250A 25kA
VCB 36 kV
1250A 25kA
VCB 36 kV
1250A 25kA
VCB 12 kV
850A 25kA
VCB 12 kV
850A 25kA
VCB 12 kV
850A 25kA 50BF BREAKER FAILURE RELAY
50/50N
25 SYNCHRO-CHECK RELAY
CT 100-200/1 CT 100-200/1 CT 100-200/1 CT 100-200/1 CT 100-200/1 W Fi kWh CT 100-200/1
Trans. Protection 50/50N 67/67N Trans. Protection 50/50N 67/67N Trans. Protection 50/50N 67/67N Trans. Protection 50/50N 67/67N Trans. Protection Trans. Protection 50/50N 67/67N
Measuring W Fi kWh Measuring W Fi kWh Measuring W Fi kWh Measuring W Fi kWh Measuring Measuring W Fi kWh
A A A A
21 DISTANCE RELAY
V V V V
LA 30kV 10 kA Var REACTIVE POWER METER
PT 200 VA; Cl 3P/0.2
LA 30kV 10 kA
33KV 110V 110V
3 3 3
Outdoor Transformer Feeder 1 Feeder 2 Feeder 3 A AMMETER
local distribution local distribution local distribution
33/11 kV 6/8 MVA
with OLTC 17 taps
V VOLT METER
Feeder for local
W WATT METER
33 kV distribution
From local LA 9kV 10 kA
Var REACTIVE POWER METER
hydropower Projects
Wh ENERGY METER
DS DISCONNECTING SWITCH
CB CIRCUIT BREAKER
400 V distribution LA LIGHTNING ARRESTOR
MCCB switch gear panels CT CURRENT TRANSFORMER
200 A
CVT CAPACITIVE VOLTAGE TRANSFORMER
400 V Bus system VT VOLTAGE TRANSFORMER
WT WAVE TRAP/COUPLING CAPACITOR
MCCBs
For self consumption
of substation
PROTECTION SYSTEM IN CHAPARTOLA 132kV
SS
5064033-DCW-BHP-BSS-004
132 kV double circuit
with BEAR ACSR 132 kV double circuit
with BEAR ACSR
To Ataria
To Lamki SS
132 kV grid substation
132 kV grid substation
5.00
3.00
3.00
3.50
3.00
4.00
Other existing
switchyard 2.50
equipment at 2.50
Pahalwanpur
1.00
substation
2.50
2.50
1.00
2.50
2.50
7.50
11.50
14.50
Existing 132 kV double bus out door
CLIENT
EXISTING 132 kV DOUBLE BUS OUTDOOR
SWITCHYARD LAYOUT AT PAHALMANPUR
5064033-DCW-BHP-BSS-007
To Attaria ss To Budhi Ganga ss From Lamki ss
CVT 100 VA CVT 100 VA CVT 100 VA
132/0.11 kV 132/0.11 kV 132/0.11 kV VT 100 VA
LA 120kV 10 kA 132/0.11 kV
VT 100 VA
132/0.11 kV
LA 120kV LA 120kV 10 kA LA 120kV 10 kA
LA 120kV 10 kA
10 kA
WT 1 MH-800 A WT 1
MH-800 A
DS/ES 31.5 kA DS/ES 31.5 kA DS/ES 31.5 kA
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
CT 600-300/1A CT 600-300/1A CT 600-300/1A
DS 31.5 kA CB SF6 31.5 kA CB SF6 31.5 kA CB SF6 31.5 kA
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
145 kV, 1250 A
132 kV 2000 A
Aluminium bus I
VT 100 VA
132/0.11 kV
DS 31.5 kA DS 31.5 kA DS 31.5 kA DS 31.5 kA
145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A 145 kV, 1250 A
VT 100 VA
132/0.11 kV
132 kV 2000 A
Aluminium bus II
DS 31.5 kA

Extend two bays and shift wave


145 kV, 1250 A CB SF6 31.5 kA trap, electrical connections,
145 kV, 1250 A
communication and other
CT 600-300-150/1A settings for Lamki SS from the
DS 31.5 kA
DS/ES 31.5 kA
145 kV, 1250 A existing bay.
145 kV, 1250 A
LA 120kV 10 kA
Outdoor X-mer
132/11 kV 24/30
MVA ONAN/ONAF
PROPOSED 132 kV DOUBLE BUS OUTDOOR
SWITCHYARD AT PAHALMANPUR
5064033-DCW-BHP-BSS-009
Scope of work
under this job:
132 kV double circuit 132 kV double circuit
132 kV double circuit with BEAR ACSR
with BEAR ACSR with BEAR ACSR
To Ataria To Budhi Ganga To Lamki SS
132 kV grid substation 132 kV substation 132 kV grid substation
A
3.00
3.00
3.50
3.00
4.00
Other existing 2.50
switchyard 2.50
equipment at
1.00
Pahalwanpur
2.50
substation
2.50
1.00
2.50
2.50
A
PROPOSED 132 kV DOUBLE BUS OUTDOOR
SWITCHYARD LAYOUT AT PAHALMANPUR
5064033-DCW-BHP-BSS-008
SECTION E-E 33 kV TRANSFORMER BAY
3m 2m 2m 4m

TRANSFORMER
DS

CB

CT
33 kV BUS

33/11 kV
Department of Electricity Development
Budhiganga, Pahalmanpur and Chapartola 33 kV Transformer TENDER PROPOSE ONLY NOT IN SCALE DRAWING No.
Substation SS-07
SECTION E-E 33 kV TRANSFORMER BAY
3m 2m 2m 4m

TRANSFORMER
DS

CB

CT
33 kV BUS

33/11 kV
Department of Electricity Development
Budhiganga, Pahalmanpur and 33 kV TENDER PROPOSE ONLY NOT IN SCALE DRAWING No.
Transformer SS-07
Chapartola Substation
SECTION A-A 132 kV Line Bay

3m
11.5 m
AL Bus
AL Bus

7.5m
5m

2.5 m
3m 2m 3m 3m 3m 7m 3m 3m 3m 3m 5.5 m 3m

MAIN BUS
GYNTRY

MAIN BUS I

GYNTRY
DS

DS

DS
CB
VT

CT

BUS VT
LA

BUS VT

II
Department of Electricity Development
Section A-A TENDER PROPOSE ONLY NOT IN SCALE DRAWING No.
Budhiganga, Pahalmanpur and
132 kV Line Bay SS-03
Chapartola Substation
SECTION B-B Bus Coupler
7.5m

3m 5.5m 3m 5.5m 3m 3m 3m 4m 3m 3m 3m
MAIN BUS

GYNTRY
MAIN BUS I
GYNTRY
DS

DS
CB
BUS VT

CT
BUS VT
II
Department of Electricity Development
Budhiganga, Pahalmanpur and Chapartola Bus Coupler TENDER PROPOSE ONLY NOT IN SCALE DRAWING No.
Substation SS-04