PROCEDURE QUALIFICATION RECORD

0
PQR NO.: SAIPL/AIPPL/PQR/01 Date:

TENSILE TEST (QW-150)


Specimen No. Width - mm Thickness - mm Area Ultimate total load - Ultimate Unit Stress Type of Failure & Location
(Sq. mm) KN
TT1 18.98 7.44 141.21 67.8 480 Broken in Parent Metal, Ductile Fracture
TT2 18.99 7.42 140.90 67.0 475 Broken in Parent Metal, Ductile Fracture

GUIDED - BEND TESTS (QW-160)


Type and Figure No. Result
Face Bend "FB-1" Satisfactory
Face Bend "FB-2" Satisfactory
Root Bend "RB-1" Satisfactory
Root Bend "RB-2" Satisfactory

TOUGHNESS TEST (QW-170)


Specimen No. Notch Location Specimen Size Test Temp. Impact Values Drop Weight Break (Y/N)
Ft. lbs. % Shear Mils

Not Applicable

FILLET - WELD TEST (QW-180)


Test Not Applicable

Result-Satisfactory: Yes/ No Penetration into Parent Metal: Yes / No

Macro Results:

Other Tests

Type of Test RADIOGRAPHIC

Analysis FOUND SATISFACTORY

Other None

Welder's Name Clock No.: Stamp No. W1

Test Conducted By : Laboratory Test No. :

Welding Supervised by :
Mechanical Testing witnessed by:

We certify that the statement in this record are correct and that the test weld were prepared, welded and tested in accordance with the
requirements of Section IX of the ASME BOILER AND PRESSURE VESSEL CODE 2007, ADDENDA 2008

Manufacturer: APPROVED BY: