HemoCue® Hb 201+ System

The Standard for Have Confidence in Your


Uncompromising Answers at the Point of Care
Accuracy Precise factory calibration against the
ICSH reference method
Providing lab accuracy and ease of use, the Patented microcuvette technology with
excellent lot-to-lot reproducibility
­HemoCue® Hb 201+ system has become a standard
in Hb point-of-care testing. Healthcare providers Date and time storage for up to 600 results
around the world rely on the immediate results so Blood-based liquid controls available
they can make the right decisions when they need
them most — right at the point of care. Get Easy Access to
Lab-Quality Accuracy
With dedicated support and service as well as
Capillary, venous or arterial whole
unmatched training and education based on over 30
blood sample
years of experience, you can count on HemoCue
Brief training with virtually no maintenance
for the right solutions for all your needs.
Link result with patient ID for medical
Accuracy Starts With Us record integration
Printer interface

To learn more about the HemoCue® Hb 201+


system, please scan the QR-code with your
smartphone or visit hemocue.com
HemoCue® Hb 201+ System
Principle Modified azidemethemoglobin reaction;
HemoCue® Hb 201+ vs ICSH
dual wavelengths (570 nm and 880 nm)
for compensation of turbidity

Hb 201+ – All Test Method Results


25

Calibration Factory calibrated against the ICSH 20

reference method; needs no further


calibration 15

Sample Material Capillary, venous or arterial whole blood


10

Measurement 0–25.6 g/dL (0–256 g/L,


Range 0–15.9 mmol/L) 5

Results Within 60 seconds 0


0 5 10 15 20 25

All Comparison Method Results, ICSH (A 540–A700)


Sample Volume ~10 µL

Dimensions 160×43×85 mm
(6.30×1.69×3.35 inches)

Weight 350 g (0.77 pounds) with batteries


installed

Storage Temp. Analyzer: 0–50 °C (32–122 °F)


Microcuvettes: unopened 15–30 °C
(59–86 °F); three-month open vial
stability

Operating Temp. 15–30 °C (59–86 °F)

Power AC Adapter or 4 AA batteries

Interface Printer and HemoCue® Basic Connect™


including optional barcode scanner

Quality Control Built-in ”selftest”; optional liquid


controls

Three Simple Steps

12.4 g/dL

Hb 201+
GPM307INDON 170208

1 Fill microcuvette. 2 Place microcuvette 3 View results.


into analyzer.

PT. Medquest Jaya Global | Menara Salemba 6th Fl Zone 1 | Jl. Salemba Raya No. 5-5A | Jakarta Pusat 10440