Condenser Operation and Maintenance - 2202 Words - Research Paper Example
Condenser Operation and Maintenance - 2202 Words - Research Paper Example
Table of Contents
1. Introduction
2. Design, Operation, and Application of the Surface Condenser
3. Surface Condenser Installation
4. Operating the Surface Condenser
5. Maintenance of the Surface Condenser
6. Effects of Air in a Condenser
7. Design and Operation of Single and Two-Stage Air Ejectors
8. Operation and Design Considerations for Condensate Extraction Pumps
9. Conclusion
10. Works Cited
Introduction
A steam condenser is a device or an appliance in which steam condenses and heat released by steam is absorbed by water
(Rajput 4). According to Graham Corporation (3), a surface condenser is designed to ensure that a turbine can operate
efficiently while at the same time allowing the condensation of steam to occur. Later, the condensed steam is fed back into the
system to create a cool environment within the turbine. These activities are handled proficiently to reduce wastage of resources
and guarantee reliable performance of the system.
This paper provides a discussion on condensers and other accessories contained within the steam turbine operation.
Ordinarily, the steam that gets into the condenser system has to be condensed fully. However, some air enters the system
through leakages and other means and is not affected by the said condensation process. This air eventually combines with the
steam and gets condensed in the process. The air cooling zone within the condenser system takes advantage of cold tubes to
facilitate the cooling of air that mixes with water vapor. The expulsion of the waterlogged air is facilitated by venting
paraphernalia such as air ejectors and ring pumps. In some cases, both tools may be utilized for maximum efficiency.
The whole idea of constantly getting rid of air from the condenser system is to ensure that at any particular time of operation, a
desirable free space or vacuum is present within the system. Apparently the build up of air within the condenser can have a
detrimental effect and reduce the effectiveness of the condenser system by causing the pressure to go up uncontrollably. To
cut down on the amount of saturated air, Graham Corporation (4) suggests that the air should be cooled before being channeled
into the venting apparatus. A poor cooling procedure may easily overwhelm the venting equipment and make it malfunction. It is
also important to eliminate any openings that can lead to leakages and hence affect the operation of the condenser.
Figure 1 shows the structural design of the surface condenser. The system has steam inlet that acts as a draining point for the
condenser. Impingement protection keeps the tubes safe from any form of damage. The condenser shell is provides the free
space needed around the tubes. Besides the protection offered by the condenser shell, tube support plates are included in the
design for additional fortification. The shell expansion joint is used to deal with tension as a result of the expansion experienced
between the tubes and the shell. Tubes themselves contain water typically used in the cooling process. Further, they provide a
separation between the condensing side and the cooling end of the condenser. Dome area is an open space over the tubes and
facilitates the distribution of steam. The shell flange provides a point to fix the tube sheets to the shell air off-take provides a
link to the venting apparatus of the condenser.
The pressure release connection is used to ensure that the condenser is not subjected to unbearable pressure. The Hot-well
offers some form of storage for the condensate while condensate outlets provide links to condensate pumps. Support saddles
are used as a base for the condenser to rest on. Tube sheets are used to keep the tubes firm in the system as well to offer
separation for the steam and the cooling substance on the other end. The water box shielded using a water box cover creates a
channel for smooth water circulation within the condenser system. Water box flanges are used to affix the water box to the tube
sheet or to the water box cover. The function of pass partitions is to split the water channels based on the needed number of
tube passes. The water inlet and the water outlet are connections for the cooling water supply and return. Finally, hand holes
are used for examining the tube sheets and tube ends.
Mechanically, the tubes in the surface condenser usually extend to penetrate the tubes structurally located at the two extreme
ends of the condenser. To ensure that no deflection is experienced within the system and that no damage occurs to any of the
tubes, support is guaranteed using strategically placed support plates. The support plates ensure that the tubes are firmly
placed within the system to avoid any damage resulting from vigorous activities undertaken by the system.
First, the installer should ensure that the distance needed to link the outlet for the vapor to the venting tool is kept at a
minimum. This apparently allows for effective control of the pressure drop.
The second consideration has to do with the removal of the condensate. Based on best practice, the installer should ensure that
the condensate drain system can accommodate the correct amount of pressure required to maintain a desirable performance.
Operating the Surface Condenser
Ludwig (211) provides a sequence of steps to ensure a successful operation of the surface condenser. First, all the vent valves in
the system must be in place and fully operational. It is then important to check and ensure that valves attached to the water box
are well placed to get rid of air from within the condenser. Next, valves inside the condenser have to be opened in order to
facilitate a smooth circulation of water while ensuring that the water boxes are constantly filled with water. The water in the hot-
well should then be checked to ensure that it roughly somewhere around the middle. In case the condensate is used as the
coolant, its valves should be left open. The situation is, however, different when cold water is used for cooling purposes. Once
all the above directions have been taken into account as expected, the condensate pump can then be started followed by the
vacuum venting apparatus. Finally, the steam turbine is started once a desirable free space is realized.
First, it leads to lower thermal efficiency which consequently hinders effective operation of the condenser system. The leaked
air in the condenser results in increased back pressure on the prime mover which means that there is loss of heat drop and
consequently the thermal efficiency of the steam power plant is drastically reduced.
Secondly, leaked air in the condenser leads to an increased requirement of the cooling water. The leaked air lowers the partial
pressure of steam which means a lowered saturation temperature of steam. As the temperature saturation of the steam
continues to go lower, its latent heat increases. An increased amount of cooling water to provide increased latent heat in the
condenser will thus be required.
Third, leaked air in the condenser leads to reduced heat transfer. Typically, air has poor thermal conductivity. As a result, the
leaked air eventually reduces the rate of heat transfer from the vapor, and consequently this requires the surface of the tubes of
a surface condenser to be increased for a given condenser capacity.
Finally, leaked air in the condenser will lead to corrosion. Ostensibly, the presence of air in the condenser increases the
corrosive action and this ends up reducing the life of the tubes and other parts within the condenser. It is thus imperative to
ensure that every necessary precaution is taken to safeguard the condenser and give it a long life.
The direct contact heater is supplied with condensate from the condensate pumps together with condensate drains from steam
piping and various heaters. The condensate is sprayed into the steam atmosphere at the top of the heater along with any drains
returned, and the heated water is pumped a long in turn from a bottom suction by the main pumps.
Since the feeder pumps which take suctions from the direct contact heater, pump water that is almost saturated, the heater
must normally be located 30 to 50 feet above the pumps in order to provide enough positive suction head to prevent the feed
pumps from having a tendency to flash when inevitable pressure fluctuations occur in the heater during unexpected changes
(Stamper and Richard 24). Consequently, the heater must be well located in the boiler room casing, or special feed booster
pumps designed to operate with a low suction head must be provided. The main pumps are quite vital and very hard to maintain,
and as a result, they can very easily be damaged when the condenser malfunctions. The pumps are usually located in the lower
level in order to achieve maximum net positive suction effect.
According to Massoud (877), it is important to employ the appropriate condensate pumps and condensate booster pumps in
coming up with the design head and the flow rate. The same principle applies to other types pumps used within the condenser
such as the main feed water pump and the feed water heater pump.
Conclusion
This paper has presented a discussion on various aspects of the surface condenser. Its design, installation, operation, and
maintenance have elaborated been explained. Other issues regarding the surface condenser considered in the paper include
effects of air leakage on a condenser, the workings of single stage and two stage air ejectors, and operation and design
considerations for condensate extraction pumps.
Works Cited
Graham Corporation. Surface Condenser: Operation, Maintenance and Installation Manual, Batavia, NY: Graham Corporation,
n.d., Print.
Ludwig, Ernest. Applied Process Design for Chemical and Petrochemical Plants, Woburn, MA: Gulf Professional Publishing, 1995.
Print.
Massoud, Mahmoud. Engineering Thermofluids: Thermodynamics, Fluid Mechanics, and Heat Transfer, College Park, MD:
Springer, 2005. Print.
Rajput, Rao. Thermal Engineering, New Delhi, India: Laxmi Publications, 2010. Print.
Stamper, Eugene and Richard Koral. Handbook of Air Conditioning, Heating, and Ventilating, New York: Industrial Press Inc.,
1979. Print.