Installation guide

Radar gauge Antennas

April 2015
Part no. 4416.642_Rev8

Enraf BV
PO Box 812
2600 AV Delft
The Netherlands

Tel. : +31 15 2701 100


Fax : +31 15 2701 111
E-mail : hfs-tac-support@honeywell.com
Website : http://www.honeywellenraf.com

Installation Guide Radar Gauge Antennas Page 1


Preface

Preface

This installation guide is intended for technicians involved in mechanical and electrical installation of
the Enraf Series 970, 971, 973 SmartRadar and SmartRadar FlexLine. It describes the antenna
installation, which is identical for both types of SmartRadar. It should be noted that some legacy
antennas such as T06, W06 and RoD are not available anymore.
High temperature applications can be covered with the F06 or F08 antenna, depending on the
existing nozzle size. See page 6.

EC declaration of conformity

Refer to the installation guide of the instrument (970, 971, 973 SmartRadar and SmartRadar
FlexLine).

Safety aspects, legal aspects

Refer to the installation guide of the instrument.

Page 2 Installation Guide Radar Gauge Antennas


Table of contents

Table of Contents

Preface ......................................................................................................................................... 2

Flange adapter.............................................................................................................................. 5

Tank separator.............................................................................................................................. 5

Free space 6” and 8” planar antennas .......................................................................................... 6


Antenna position ..................................................................................................................... 6
Field orientation planar antenna.............................................................................................. 7
Manhole cover preparation ..................................................................................................... 7
Install antenna with flange adapter on nozzle ......................................................................... 8

Stilling well 6" to 12" planar antennas ......................................................................................... 10


Install antenna with flange adapter on stilling well ................................................................. 10
Install antenna on dip/sample hatch ...................................................................................... 11
Stilling wells with reducer ‘bottleneck’ ................................................................................... 11

High pressure 4" horn antenna ................................................................................................... 12


Install horn antenna to adapter flange (4" or 6") .................................................................... 13
Installation on 4" ball valve (type H04/B1 and H04/B4) ......................................................... 14
Place horn antenna with 4" adapter flange in spool piece ............................................ 15
Place tank separator and position adapter flange ........................................................ 15
Installation in 4" SCH40 stilling well (type H04/N4) ............................................................... 17
Place horn antenna with 4" adapter flange in stilling well ............................................. 18
Place ball valve and position adapter flange ................................................................ 18
Install tank separator ................................................................................................... 19
Installation in 4" SCH10s insert pipe (type H04/N1) .............................................................. 21
Place horn antenna with 6" adapter flange in insert pipe ............................................. 22
Place ball valve and position adapter flange ................................................................ 22
Install tank separator ................................................................................................... 23

Appendix A Flange adapters and flanges ............................................................................. 25

Appendix B Dimensional drawings antennas........................................................................ 27

Appendix C Related publications .......................................................................................... 31

Installation Guide Radar Gauge Antennas Page 3


Page 4 Installation Guide Radar Gauge Antennas
Flange adapter / tank separator

Flange adapter

Prepare flange adapter to install tank separator for atmospheric and medium pressure antennas:
• free space: F06 - F08 antennas
• stilling well: S06 - S12 antennas

Use any flange adapter of 10 to 30 mm (0.03 to 0.10”) thickness or, alternatively, prepare
counter flange.

Flange adapter must have hole pattern of roof nozzle


flange. Refer to Appendix A for mechanical details.

For safety, the flange adapter must be finished to 20 µm over a diameter of 100 mm (4") at
the underside of the flange adapter around tank separator hole. However, for adequate
sealing in pressurized applications, the surface finish requirement is 1.6 µm.

Tank separator
The tank separator for planar antennas is already fixed to the antenna.
Install tank separator and antenna as follows (figure 1):

1) Check if O-ring (1) on tank separator is in 4


place.
3
2) Insert tank separator (2) from underneath
flange adapter.
Mind locking pin! 2

3) Place M55 inside star washer (3) over tank


separator. 1

4) Tighten tank separator nut (4).

Figure 1 Install tank separator

Installation Guide Radar Gauge Antennas Page 5


Installation F06 – F08 antenna

Free space 6” and 8” planar antennas


The 6" planar antenna (F06) can be installed on a 6" (or larger) roof nozzle or on a manhole.
The 8" planar antenna (F08) can be installed on an 8" (or larger) roof nozzle or on a manhole.
Refer to section: flange adapter / tank separator.
Measuring range: up to 30 m (98 ft) for F06; up to 75 m (246 ft) for F08
For longer distances contact factory.
Temperature range: -40°C to +100°C (-40°F to +212°F)
Process temperature range: -200°C to +250°C (-328°F to +483°F)
For high temperature applications, planar antennas need to be mounted in
accordance with the installation manual. For temperatures > 250°C (482 °F)
consult your local Honeywell Enraf representative.
Maximum operating pressure: 6 bar / 0.6 MPa (87 psi)
Wetted parts: AISI 316 and FEP
Stem length: 50 mm (0.16 ft); 300 mm (0.98 ft); 500 mm (1.64 ft);
800 mm (2.62 ft)

Antenna position
If possible, the radar beam should avoid large reflecting obstacles.
The antenna can be positioned anywhere on the tank roof, except in the centre when the tank
has a dome roof. For optimum accuracy, a minimum distance from the tank shell is
recommended (refer to table below).
Antenna Minimum distance from tank shell
97x without 97x with
SmartRadar
AdvancedDSP AdvancedDSP
FlexLine
software enabled software enabled
F06 0.28 x tank height 0.14 x tank height 0.14 x tank height
F08 0.15 x tank height 0.1 x tank height 0.1 x tank height
For normal applications it is recommended to select the stem length so that antenna position
is below roof nozzle as shown in figure 2. For high temperature applications and those
applications where it is required to pull up the antenna into the nozzle to meet maximum safe
fill requirements, the flange with separator’s hole off center must be used as shown in figure 3.

Figure 2 Normal applications: antenna Figure 3 High temperature applications: Pull up


below nozzle antenna in nozzle

Page 6 Installation Guide Radar Gauge Antennas


Installation F06 - F08 antenna

Field orientation planar antenna


Install antenna with tank separator as far as
possible from the tank wall and with magnetic
field (H-field) and electric field (E-field) directed E Locking
in a 45° angle towards tank shell (refer to pin hole
figure 4).
Note: For the F06 antenna, this configuration is
appropriate for the new F06 antenna, Antenna H
that can be recognized by the off centre Tank shell
stem. The old F06 antenna has the stem Nozzle
in the centre, comparable to the S06
antenna (see Appendix B).

Figure 4 Field orientation planar antenna

Manhole cover preparation


For easy installation, make 6”/8" nozzle
on manhole cover.

Limit nozzle height to minimize antenna


stem length. Nozzle can be constructed
from a 6”/8", 150 lb welding neck Figure 5 Manhole nozzle for SmartRadar
flange. Refer to figure 5.

Installation Guide Radar Gauge Antennas Page 7


Installation F06 – F08 antenna

Install antenna with flange adapter on nozzle

Refer to figure 6.
Tank shell
1) Place planar antenna / flange adapter
assembly on roof nozzle. 1

2
2) Position flange adapter so that:
3
a) tank separator (1) is located as far
as possible from tank shell, while
E-field and H-field are directed at
an angle of 45° towards the tank Figure 6 Position of antenna assembly on
shell (refer to figure 4); roof (manhole) nozzle

b) locking pin hole (2) on top of tank


separator is directed at an angle
of 45° towards tank shell.

3) Secure flange adapter.


Line (3) in figure 6 indicates antenna
position.

Warning
For proper bonding of flange adapter,
install a copper strip under one
of the flange bolts.

Place sharks ring between flange


and strip (figure 7).

Figure 7 Example of flange bond

Page 8 Installation Guide Radar Gauge Antennas


Installation F06 - F08 antenna

Installation Guide Radar Gauge Antennas Page 9


Installation S06 - S12 antenna

Stilling well 6" to 12" planar antennas

Refer to section: flange adapter / tank separator.


Measuring range: up to 75 m (246 ft). For longer distances contact factory.
Temperature range: -40°C to +100°C (-40°F to +212°F)
Process temperature range: -200°C to +250°C (-328°F to +483°F)
Maximum operating pressure: 6 bar / 0.6 MPa (87 psi)
Wetted parts: AISI 316 and FEP
Stilling well sizes: 6” (S06), 8” (S08), 10” (S10), 12”, 14” (S12), 16” (S08),
20” (S10), 24” (S12)
Stem length: 50 mm (0.16 ft); 300 mm (0.98 ft); 500 mm (1.64 ft);
800 mm (2.62 ft)

Stilling well should have at least one row of equalisation holes with a pitch of 300-500 mm
(12-20").
Recommended hole diameter: 15 mm (0.6") for a 6" stilling well
20 mm (0.8") for 8" and 10" stilling well
25 mm (1") for a 12" stilling well

Inner side stilling well should be free from burrs at equalisation hole positions. Stilling well should
be straight and consistent in diameter without welding seams at inside; obliquity should be better
than 1:1000 (1 mm per 1 m stilling well length).

Install antenna with flange adapter on stilling well

Refer to figure 8.

1) Place antenna / flange adapter


assembly on stilling well's counter
flange.
1
2) Position of locking pin hole on tank
separator (1) determines position of
Antenna Unit / SmartRadar LT.

3) Secure flange adapter.


Figure 8 Antenna assembly on stilling well

Page 10 Installation Guide Radar Gauge Antennas


Installation S06-S12 antenna

Warning 1
For proper bonding of flange,
install a copper strip under one
of the flange bolts.

Place shark rings (1) between flange


and strip (figure 9).

Figure 9 Example of flange bond

Install antenna on dip/sample hatch


In case the antenna is installed on a dip/sample
hatch the antenna stem length should be such that
the antenna is positioned above the hatch. The
spool piece should have the same inner diameter as
the stilling well.
A spool piece with dip/sample hatch is available in
the price list. Refer to figure 10.

Figure 10 Spool Piece with dip hatch

Stilling wells with reducer ‘bottleneck’


In case of stilling wells with a reducer ‘bottle neck’, a
stilling well antenna must be selected with a
diameter half of the stilling well diameter. Refer to
figure 11 and table below.

Stilling well
Antenna
diameter
S06 12”
S08 16”
S10 20”
S12 24”
Note: Only with SmartRadar FlexLine.
Figure 11 Position of antenna in double
diameter stilling well

Installation Guide Radar Gauge Antennas Page 11


Installation H04 antenna

High pressure 4" horn antenna


The stilling well should have at least one row of equalisation holes with a diameter of 5 - 10 mm
(3/16 - 3/8") at 500 mm (20") pitch. Local regulations may require a different pitch and/or size of
equalisation holes. In this case consult Enraf or the local representative. Stilling well’s inner side
should be smooth and free from burrs.

The equalisation hole position in the pipe should be clearly marked on the stilling well flange.
When using verification pins, they should also be in line with the mark on the flange.
Refer to figure 12.

Mark on flange in line Mark on flange in line


with equalisation holes with verification pins

4" 300 lb flange with 6" 300 lb flange with


4" Sch. 10 pipe or 4" Sch. 10 insertion pipe
4" Sch. 40 pipe

Figure 12 Holes and verification pins in line with mark on flange

Temperature range: -200°C to +250°C (-330°F to +482°F)


Operating pressure: Up to 40 bar / 4 MPa (580 psi)
There are four configurations:

• on a 4" ball valve, type H04/B1


• on a 4" ball valve, type H04/B4
• in a 4" SCH40 stilling well, type H04/N4
• in a 4" SCH10s insert pipe, type H04/N1

Page 12 Installation Guide Radar Gauge Antennas


Installation H04 antenna

Install horn antenna to adapter flange (4" or 6")

This procedure is common for all configurations.

Refer to figure 13.

1) Place four Allen head screws M6 x 60 (2)


with springs (3) and nuts (4) in Horn
Antenna (1). 6

2) Insert bushing (5) from underneath adapter 5


flange (6).
4
3) Place antenna (1) against bushing and turn
Allen head screws (2) into adapter flange.
Secure Allen head screws with nuts (4) 3
against adapter flange. Leave sufficient
space for springs (3) to be pressed at 2
least 8 mm (5/16").
1

Figure 13 Installing antenna to adapter flange

Installation Guide Radar Gauge Antennas Page 13


Installation H04 antenna

Installation on 4" ball valve (type H04/B1 and H04/B4)

Refer to figure 14.

Item Description 4

1 4" SCH10/SCH40 stilling well with


welding neck flange (300 lbs)

2 4" full bore ball valve (300 lbs)

3 spool piece
3

4 tank separator

Note:
The 4” full bore ball valve should be well
aligned on welding neck flange.
Bad alignment of internal diameters will
cause false reflections, resulting in level
inaccuracies. Also, spool piece should be
well aligned, as cone will lower into ball
valve housing.
2

Note:
The spool piece should provide a plug for
a vent facility (by means of a small valve)
and/or pressure gauge.
1
Start installation with ball valve and spool
piece; mind alignment as described in note
above. Figure 14 Assembly of H04 antenna on top of
4" ball valve

Page 14 Installation Guide Radar Gauge Antennas


Installation H04 antenna

Place horn antenna with 4" adapter flange in spool piece

1) Place 4" gasket on spool piece flange.

2) Carefully lower the antenna/adapter flange assembly inside spool piece. Do not yet fix adapter
flange to spool piece.

Place tank separator and position adapter flange

Refer to figure 15.

1) Place 1" gasket (1) between the four stud


bolts on 4" adapter flange.
5

2) Place tank separator (2) over the four stud 3


bolts. Tighten with four nuts.

Note:
Tighten nuts carefully on opposite sides.
Check that bushing is pressed downwards.
2

4
3) Turn 4" adapter flange in position.
The correct position is as indicated in 1
figure 15. Hole for locking pin (3), which is
90° away from vent plug (4), is in line with
marker on stilling well flange (5).

4) Secure 4" adapter flange to spool piece


flange with standard bolts and nuts.

Figure 15 Position of adapter flange with


respect to equalisation holes or
verification pins

Installation Guide Radar Gauge Antennas Page 15


Installation H04 antenna

Warning
For proper bonding of all flanges,
install a copper strip under one
of the flange bolts.

Place shark rings (1) between flange


and strip (figure 16).

Marker

Figure 16 Example of flange bond

Page 16 Installation Guide Radar Gauge Antennas


Installation H04 antenna

Installation in 4" SCH40 stilling well (type H04/N4)

Refer to figure 17.

4
Item Description

1 4" SCH40 stilling well with


300 lb flange 3

2 4" 300 lb adapter flange

3 1" full bore ball valve 2

4 tank separator

Refer to section: install horn antenna to


adapter flange. 1

Figure 17 Assembly of H04 antenna in


4" SCH40 stilling well

Installation Guide Radar Gauge Antennas Page 17


Installation H04 antenna

Place horn antenna with 4" adapter flange in stilling well

1) Place 4" gasket on stilling well flange.

2) Carefully lower antenna/adapter flange assembly inside stilling well. Do not yet fix adapter
flange to stilling well flange.

Place ball valve and position adapter flange

Refer to figure 18.

1) Place 1" gasket (1) between the four stud


bolts on the 4" adapter flange.
3
2) Place 1" ball valve (2) over the four stud
bolts. Tighten with four nuts.

Note: 2
Tighten nuts carefully on opposite sides.
Check that bushing is pressed downwards.
1

3) Turn 4" adapter flange in position.


The correct position is found when handle
4
of ball valve (3) is in line with the marker on
stilling well flange (4).

4) Secure 4" adapter flange to stilling well


flange with standard bolts and nuts.

Figure 18 Position of adapter flange with


respect to equalisation holes or
verification pins

Page 18 Installation Guide Radar Gauge Antennas


Installation H04 antenna

Install tank separator

Refer to figure 19.

1) Place 1" gasket (1) on 1" ball valve


flange (2).
6
2) Place tank separator (3).
Mind the position! 4
The correct position is as indicated in figure 19.
Hole for locking pin (4), which is 90° away from
vent plug (5), is in line with marker on the
stilling well flange (6).
3
3) Secure the tank separator with 4 standard bolts
and nuts. 5

Figure 19 Position of tank separator

Installation Guide Radar Gauge Antennas Page 19


Installation H04 antenna

Warning
For proper bonding of all flanges,
install a copper strip under one
of the flange bolts.

Place shark rings (1) between flange


and strip (figure 20).

Marker

Figure 20 Example of flange bond

Page 20 Installation Guide Radar Gauge Antennas


Installation H04 antenna

Installation in 4" SCH10s insert pipe (type H04/N1)

Refer to figure 21.

Item Description 6

1 6" SCH40 stilling well (or nozzle)


5
2 4" SCH10s insert pipe

3 6" 300 lb intermediate flange


4
4 6" 300 lb adapter flange 3

5 1" full bore ball valve


2
6 tank separator 1

Refer to section: Install horn antenna to


adapter flange. Figure 21 Assembly of H04 antenna in
4" SCH10s insert pipe

Installation Guide Radar Gauge Antennas Page 21


Installation H04 antenna

Place horn antenna with 6" adapter flange in insert pipe

1) Place 6" gasket on intermediate flange.

2) Carefully lower antenna/adapter flange assembly inside insert pipe. Do not yet fix adapter
flange.

Place ball valve and position adapter flange

Refer to figure 22.

1) Place 1" gasket (1) between the four stud


bolts on 6" adapter flange.
3
2) Place 1" ball valve (2) over the four stud
bolts and tighten it with four nuts.
2
Note:
Tighten nuts carefully on opposite sides. 1
Check that bushing is pressed downwards.

The correct position is found when handle 4


of ball valve (3) is in line with marker on
intermediate flange (4).

4) Secure 6" adapter flange to stilling well


flange with standard bolts and nuts.

Figure 22 Position of adapter flange with


respect to equalisation holes or
verification pins

Page 22 Installation Guide Radar Gauge Antennas


Installation H04 antenna

Install tank separator

Refer to figure 23.

1) Place 1" gasket (1) on 1" ball valve


flange (2).
6

2) Place tank separator (3). 4


Mind the position!
The correct position is as indicated in
figure 23. Hole for locking pin (4), which is
90° away from vent plug (5), is in line with
marker on intermediate flange (6).
3

3) Secure tank separator with 4 standard 5


bolts and nuts.
1

Figure 23 Position of tank separator

Installation Guide Radar Gauge Antennas Page 23


Installation H04 antenna

Warning
For proper bonding of all flanges,
install a copper strip under one
of the flange bolts.

Place shark rings (1) between flange


and strip (figure 24).

Marker

Figure 24 Example of flange bond

Page 24 Installation Guide Radar Gauge Antennas


Appendix

Appendix A Flange adapters and flanges

D
K

ø56 (2.20”)

35 1.32”) Detail "A"


See detail "A" ≥ 3 (0.12”)

 7 (0.28”) ø6 (0.24”)
T

100 (3.94”)
*

Thickness: 10 ≤ T ≤ 30 (0.39” ≤ T ≤ 1.18”)

Flange D K d n a Antenna Part no. Part no.


(number type (cs version) (ss version)
of holes)
279.4 241.3 22.2 35
NPS 6" class 150 8 F06 A0186993 A0186994
(11”) (9.5”) (0.875”) (1.38”)
342.9 298.4 22.2 50
NPS 8" class 150 8 F08 A0186422 A0186424
(13.5”) (11.75”) (0.875”) (1.97”)
320 280 18 45
NW200 ND6
(12.6”) (11.0”) (0.7”)
8
(1.77”)
F08 - -
340 295 23 45
NW200 ND10
(13.4”) (11.6”) (0.9”)
8
(1.77”)
F08 - -
Notes: * ) general finish 20 μm, gas finish 1.6 μm

Installation Guide Radar Gauge Antennas Page 25


Appendix

D
K

ø56 (2.20”)

Detail "A"
35 (1.38”)

See detail "A"  ≥ 3 (0.12”)


T

100 (3.94”)  7 (0.28”) ø6 (0.24”)


*

Thickness: 10 ≤ T ≤ 30
(0.39” ≤ T ≤ 1.18”)

Flange D K n d Antenna Part no. Part no.


(number type (cs version) (ss version)
of holes)
NPS 6" class 150 279.4 241.3 22.2 8 S06 A0186.430 A0186.431
NPS 8" class 150 342.9 298.4 22.2 8 S08 A0186.423 A0186.425
NPS 10" class 150 406.4 361.9 25.4 12 S10 A0186.426 A0186.427
NPS 12" class 150 482.6 431.8 25.4 12 S12 A0186.428 A0186.429
NW150 ND6 265 225 18 8 S06 - -
NW200 ND6 320 280 18 8 S08 - -
NW200 ND10 340 295 23 8 S08 - -
NW250 ND6 375 335 18 12 S10 - -
NW250 ND10 395 350 23 12 S10 - -
NW300 ND6 440 395 23 12 S12 - -
NW300 ND10 445 400 23 12 S12 - -
Notes: * ) general finish 20 μm, gas finish 1.6 μm

Page 26 Installation Guide Radar Gauge Antennas


Appendix

Appendix B Dimensional drawings antennas

F06 Antenna

ø40
(1.57”)

(0.91”)
23
Circlip
Antenna
stem nut

Stem length
(0.79”)
20

34.5
(1.36”)
ø139 (5.49”)

Stem length Weight


50 mm (1.57”) 0.62 kg (1.4 lb)
300 mm (11.81”) 0.97 kg (2.1 lb)
500 mm (19.69”) 1.60 kg (3.5 lb)
800 mm (31.50”) 2.65 kg (5.8 lb)

Material: Antenna housing AISI 316L, mat. no.: 1.4404


Antenna aperture cover: FEP

Installation Guide Radar Gauge Antennas Page 27


Appendix

F08 Antenna

ø40
(1.57”)

(0.91”)
23
Circlip
Antenna
stem nut

Stem length
(0.79”)
20
45
(1.77”)
ø189.5 (7.46”)

Stem length Weight


50 mm (1.57”) 1.23 kg (2.7 lb)
300 mm (11.81”) 1.58 kg (3.5 lb)
500 mm (19.69”) 1.86 kg (4.1 lb)
800 mm (31.50”) 2.25 kg (4.9 lb)

Material: Antenna housing AISI 316L, mat. no.: 1.4404


Antenna aperture cover: FEP

Page 28 Installation Guide Radar Gauge Antennas


Appendix
S06 - S12 Antennas

ø40
(1.57”)

(0.91”)
23
Circlip
Antenna

Stem length
stem nut

( 0.79”)
20
D

S06 D = ø139 (5.49”) S08 D = ø189.5 (7.46”)


Stem length Weight Stem length Weight
50 mm (1.57”) 0.62 kg (1.4 lb) 50 mm (1.57”) 1.23 kg (2.7 lb)
300 mm (11.81”) 0.97 kg (2.1 lb) 300 mm (11.81”) 1.58 kg (3.5 lb)
500 mm (19.69”) 1.60 kg (3.5 lb) 500 mm (19.69”) 1.86 kg (4.1 lb)
800 mm (31.50”) 2.65 kg (5.8 lb) 800 mm (31.50”) 2.25 kg (4.9 lb)

S10 D = ø239 (9.41” ) S12 D = ø289 (11.38”)


Stem length Weight Stem length Weight
50 mm (1.57”) 1.66 kg (3.7 lb) 50 mm (1.57”) 2.18 kg (4.8 lb)
300 mm (11.81”) 2.01 kg (4.4 lb) 300 mm (11.81”) 2.53 kg (5.6 lb)
500 mm (19.69”) 2.29 kg (5.0 lb) 500 mm (19.69”) 2.81 kg (6.2 lb)
800 mm (31.50”) 2.71 kg (6.0 lb) 800 mm (31.50”) 3.23 kg (7.1 lb)

Material: Antenna housing AISI 316L, mat. no.: 1.4404


Antenna aperture cover: FEP

Installation Guide Radar Gauge Antennas Page 29


Appendix

H04 Antenna

19 (0.75”)
(4x)

a
mm inches
( M6 ) (4x)
a ø 25 0.98"
ø89
b ø 85 3.35”
c 65 2.56” (3.50”)
d ø 32 1.26”
e 5 0.20” Connection for pressure
f 10 0.39” relief and/or pressure

113 (4.45”)
gauge 1/4" BSP (RP 1/4)

19 (0.75”)
b
c
124 (4.88”)
e d f

Material : AISI 316 mat. no.: 1.4401


Weight : 3.1 kg (6.8 lb)

Flange : 1", 300 lb, rf acc. to ANSI B16.5

104 (4.09”)

200 (7.87”)
A

165 (6.5”)

g
h

mm inches
g ø 25 0.98"
B h ø 32 1.26”
k 5 0.20”
H04*1 H04*4
A 410 (16.14”) 360 (14.17”)
B ø 107 (4.21”) ø 101 (3.98") Material : AISI 316 mat. no.: 1.4401
Weight : 5.7 kg (12.5 lb)

Material : ASTM A351 CF8M, 316 mat. no.: 1.4408 Flange : 1", 300 lb, rf acc. to ANSI B16.5
Weight : 2.9 kg (6.4 lb) Flange finish : turning, Ra: 3.2-6.3 μm

Page 30 Installation Guide Radar Gauge Antennas


Appendix

Appendix C Related publications

SmartRadar Safety instructions for installation, commissioning, operation and maintenance

Installation guide 970 SmartRadar ATi


Installation guide 971 SmartRadar LTi
Installation guide 973 SmartRadar LT
Installation guide SmartRadar FlexLine

Instruction manual 970 SmartRadar Ati


Instruction manual 971 SmartRadar LTi
Instruction manual 973 SmartRadar LT
Instruction manual SmartRadar FlexLine

Installation Guide Radar Gauge Antennas Page 31


Delftechpark 39
2628 XJ Delft

Tel. : +31 15 2701 100


E-mail : hfs-tac-support@honeywell.com
Website : http://www.honeywellenraf.com

PO Box 812
2600 AV Delft
The Netherlands

We at Honeywell Enraf are committed to excellence.

Information in this publication is subject to change without notice

Enraf is a registered trade mark. Enraf B.V. Netherlands

Page 32 Installation Guide Radar Gauge Antennas