Checking the speed displayed by the frequency converter
Check pOints Test Result Action The read value must be If the value is not f'{"\"r"",~t between 20 and 480 r.p.m. check the {"\\I(.>rc,,\Q£,ri switch tion, encoder cable con nection}. ;. < i If the error E.6? occurs, check the configuration of •the card and the encoder · connection. Operate "Lowering The read value must be If the value is not correct, 1st notch". between check the overspeed card -20 and -480 r.p.m. (fitting, switch encoder cable con nection).
If the error E.6? occurs,
• check the card
Operate «Hoisting at The read value must be If
high speed". between check the overs peed 3580 and 3620 r.p.m. card.
If the error E.65 or E.66
occurs, check the config uration of the card switches, the tightening of the encoder on the shaft, and the tightening of the connections. lnl"'l"nnilnn of the encoder can also be checked both directions. See the at CP05.
for HOIST WINCH
Checking the brake function (error E.68)
Check Test Result Action Frequency Frequency converter If an error E.68 occurs Check the state of the converter display alive, without control. frequency converter input 13 (open circuit 0 V).
Check the contact
I adjustment and wiring on the brake a normally open contact). "Hoisting If an error E.68 occurs Check the brake release.
Check the contact
adjustment and on the brake (use a normally open contact).
The frequency converter
input 13 must be 24 V DC when the brake is released.