GENERAL STRUCTURAL NOTES 2.

3.
ALL CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 3,000 PSI, UNO.
ALL CONCRETE IS REINFORCED AND CAST-IN-PLACE UNO. WHERE REINFORCING IS NOT
ROUGH FRAMING CONNECTIONS 5.3 - ENGINEERED WOOD PRODUCTS

SPECIFICALLY SHOWN OR WHERE DETAILS ARE NOT GIVEN, PROVIDE REINFORCING SIMILAR TO 1. REFERENCE STANDARDS (CURRENTLY ADOPTED EDITIONS)
CONNECTION NAILS A. ANSI / AWC NDS
1.0 - GENERAL THAT SHOWN FOR SIMILAR CONDITIONS, SUBJECT TO REVIEW BY THE OWNER'S REPRESENTATIVE.
SUBSTITUTION OF SHOTCRETE FOR CAST-IN-PLACE CONCRETE IS NOT ACCEPTABLE. STUDS TO PLATES - END NAIL (2) 16d COMMON OR (3) 10d 2. ENGINEERED WOOD I-JOIST & OPEN WEB JOIST:
1. MATERIALS AND WORKMANSHIP TO CONFORM WITH THE 2018 EDITION OF THE INTERNATIONAL 4. ROUGHEN CONCRETE SURFACES OF CONSTRUCTION JOINTS TO 14" AMPLITUDE AND CLEAN OF A. PRODUCTS BY TRUS-JOIST CORPORATION OR BOISE CASCADE. MARK MEMBERS WITH APA
STUDS TO PLATES - TOE NAIL (4) 10d
BUILDING CODE (IBC), ALONG WITH THE CALIFORNIA BUILDING CODE (CBC), LOCAL AMENDMENTS LAITANCE, FOREIGN MATTER, AND LOOSE PARTICLES. LOCATE CONSTRUCTION JOINTS AS SHOWN PRI TRADEMARK INDICATING CONFORMANCE WITH MANUFACTURING AND QUALITY
AS REQUIRED BY THE AHJ, AND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. ON THE DRAWINGS. SUBMIT ALTERNATE JOINT LOCATIONS OR JOINTS NOT SHOWN TO THE TOP PLATES & BOTTOM PLATES - 10d AT 8" OC ASSURANCE OF APA EWS STANDARD PRI-400.
2. THESE GENERAL NOTES SUPPLEMENT THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS. IN OWNER'S REPRESENTATIVE FOR REVIEW AND APPROVAL PRIOR TO PROCEEDING WITH THE WORK. SPIKE TOGETHER B. CONTRACTOR IS RESPONSIBLE FOR ERECTION BRACING TO KEEP JOISTS STRAIGHT AND 09-30-2022
CASE OF CONFLICT BETWEEN THE PLANS AND SPECIFICATIONS, CONTACT THE OWNER'S 5. AT LOCATIONS WHERE CONCRETE IS CAST AGAINST EXISTING CONCRETE, ROUGHEN CONTACT LAP AND INTERSECTIONS (4) 10d EACH SIDE JOINT PLUMB AND PROVIDE ADEQUATE LATERAL SUPPORT FOR THE INDIVIDUAL MEMBERS AND
REPRESENTATIVE. SURFACES TO 14" AMPLITUDE AND CLEAN OF LAITANCE, FOREIGN MATTER, AND LOOSE PARTICLES. THE ENTIRE SYSTEM UNTIL CONSTRUCTION HAS BEEN COMPLETED.
3. REFERENCE TO CODES, RULES, REGULATIONS, STANDARDS, MANUFACTURER'S INSTRUCTIONS OR SURFACE SHALL BE PREPARED AS SATURATED SURFACE DRY. FLOOR, ROOF, CEILING JOISTS- (2) 10d C. INSTALL BLOCKING, BRIDGING, STIFFENERS, FILLER BLOCKS AND BACKER BLOCKS IN
REQUIREMENTS OF REGULATORY AGENCIES IS TO THE LATEST PRINTED EDITION OF EACH IN 6. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR LOCATIONS OF ADDITIONAL TO PLATES OR BEAMS - TOE NAIL CONFORMANCE WITH MANUFACTURER'S STANDARDS AND AS DETAILED.
EFFECT AT THE DATE OF SUBMISSION OF BID UNLESS THE DOCUMENT DATE IS SHOWN. CONCRETE CURBS AND HOUSEKEEPING PADS NOT SHOWN. BLOCKING TO PLATE - TOE NAIL (2) 10d 3. I-JOIST MANUFACTURED BY TRUS-JOIST CORPORATION:
4. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE 7. CONTINUOUSLY MOIST CURE CONCRETE SLABS-ON-GRADE FOR 7 DAYS MINIMUM. WATER FOG A. FURNISH ALL END AND INTERMEDIATE STIFFENERS, BLOCKING AND/OR SHEAR PANELS,
NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, USE SIMILAR BLOCKING TO JOISTS - EACH END (2) 10d METAL BRIDGING ASSEMBLIES AND HANGERS, AS REQUIRED TO PROVIDE A COMPLETE
SPRAYS, PONDING, SATURATED ABSORPTIVE COVERS, OR MOISTURE RETAINING COVERS MAY BE
DETAILS OF CONSTRUCTION, SUBJECT TO REVIEW BY THE ENGINEER OF RECORD. USED. CURING COMPOUNDS ARE NOT ACCEPTABLE. CORNER STUDS 10d AT 12" OC FLOOR OR ROOF STRUCTURAL SYSTEM. DEPTHS OF JOISTS OR JOIST SPACINGS MAY NOT LOCATION:
5. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND FOR 8. CONCRETE CLEAR COVER TO REINFORCING BARS SHALL BE AS FOLLOWS, UNO: 2x LAMINATED BEAMS (2) ROWS STAGGERED 10d BE CHANGED WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER OF RECORD.
CHECKING DIMENSIONS. NOTIFY THE OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES AND AT 12" OC 4. DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS, EXCEPT AS APPROVED BY THE STRUCTURAL
RESOLVE BEFORE PROCEEDING WITH THE WORK. ENGINEER OF RECORD PRIOR TO INSTALLATION.
6. DO NOT SCALE THE DRAWINGS. LOCATION CLEAR COVER 2x6 TONGUE AND GROOVE- (1) 16d TOE NAIL & 5. MODIFICATIONS/ALTERNATES: THE SPECIFICATION IS BASED ON TRUS-JOIST CORPORATION
21541 YANKEE VALLEY ROAD
EACH BOARD TO SUPPORTING MEMBERS 16d FACE NAIL ENGINEERED WOOD PRODUCTS. NO ALTERNATIVES, MODIFICATIONS OR SUBSTITUTIONS ARE
7. PROVIDE MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH
MEASURES INCLUDE, BUT MAY NOT BE LIMITED TO, BRACING AND SHORING FOR LOADS DURING
CONCRETE PLACED AGAINST EARTH 3"
TO PARALLEL WALLS AND BEAMS ALLOWED UNLESS THE GENERAL CONTRACTOR SUBMITS IN WRITING FOR SUCH REQUESTS TO THE
HIDDEN VALLEY LAKE, CA. 95467
CONSTRUCTION. ADEQUATELY BRACE STRUCTURE AND ALL STRUCTURAL COMPONENTS AGAINST FORMED SURFACES EXPOSED ENGINEER OF RECORD FOR APPROVAL, NO LATER THAN TWO WEEKS PRIOR TO BID. ALTERNATE
WIND, LATERAL EARTH AND SEISMIC FORCES UNTIL THE PERMANENT LATERAL-FORCE RESISTING TO WEATHER OR IN CONTACT 112" 3x6 TONGUE AND GROOVE- (1) 40d TOE NAIL & 60d PRODUCTS MUST HAVE A CURRENT ICC-ES CODE EVALUATION REPORT WITH LISTED DESIGN
SYSTEMS HAVE BEEN INSTALLED. RETAIN A REGISTERED CIVIL ENGINEER WHOM IS PROPERLY WITH EARTH EACH BOARD TO SUPPORTING MEMBERS FACE NAIL PROPERTIES EQUIVALENT OR GREATER THAN SPECIFIED PRODUCTS. SUBSTANTIATING
QUALIFIED TO DESIGN BRACING, SHORING, ETC. VISITS TO THE SITE BY THE OWNER'S CALCULATIONS SHALL BE SUBMITTED.
WALL OR SLAB SURFACES 1" TO PARALLEL WALLS AND BEAMS (1) 60D FACE NAIL
REPRESENTATIVE WILL NOT INCLUDE OBSERVATION OF THE ABOVE NOTED ITEMS.
NOT EXPOSED TO WEATHER AT 8" OC
A. NAILING LIMITATIONS OF ALTERNATE SHALL BE SUBSTANTIATED AS EQUIVALENT IN AN PROJECT:
8. INFORMATION SHOWN ON THE DRAWINGS RELATED TO EXISTING CONDITIONS REPRESENTS THE ICC-ES CODE EVALUATION REPORT.
PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. REPORT CONDITIONS THAT OR EARTH B. WHEN APPLICABLE, FLOOR PERFORMANCE OF ALTERNATE SHALL BE SUBSTANTIATED AS
CONFLICT WITH THE CONTRACT DOCUMENTS TO THE OWNER'S REPRESENTATIVE. DO NOT BETWEEN PARALLEL BARS 1" EQUIVALENT TO TJ-PRO RATING OF 50.
DEVIATE FROM THE CONTRACT DOCUMENTS WITHOUT WRITTEN DIRECTION FROM THE OWNER'S 2. NAILING: C. ALL TIMBERSTRAND® LSL RIM BOARD /BLOCKING SUBSTITUTIONS SHALL BE ICC-ES REPORT
REPRESENTATIVE. SLABS ON GRADE (TOP) 112" A. DRIVE NAILS PERPENDICULAR TO THE GRAIN, UNO. EVALUATED FOR USE AS RIM BOARD/BLOCKING AND/OR BE CROSS-PLY LAMINATED.
9. REFER TO ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF FLOOR, ROOF AND WALL B. PRE-DRILL HOLES TO 3 4" OF NAIL DIAMETER WHERE SPECIFIED AND WHEN WOOD TENDS TO D. ALL EQUIVALENT FIRE AND SOUND RATINGS FOR FLOOR/CEILING ASSEMBLIES SHALL BE
EMBEDDED BOLTS 1" ALL-AROUND
OPENINGS NOT SHOWN ON THE STRUCTURAL DRAWINGS. COORDINATE THE SIZE AND LOCATION SPLIT. SUBSTANTIATED IN AN ICC-ES CODE EVALUATION REPORT OR SIMILAR THIRD PARTY
OF OPENINGS ASSOCIATED WITH, BUT NOT LIMITED TO, ELECTRICAL, MECHANICAL AND PLUMBING C. AIR-DRIVEN NAILS TO BE FULL-HEADED NAILS. DO NOT OVERDRIVE NAILS. EVALUATION AS EQUIVALENT TO TJI JOIST ASSEMBLIES.
TRADES. SUBMIT FINAL SIZING AND LOCATION REQUIREMENTS OF OPENINGS TO THE OWNER'S D. PANEL SHEATHING:
REPRESENTATIVE FOR REVIEW. 5.0 - ROUGH CARPENTRY a. AT FLOOR AND ROOF SHEATHING, USE RING SHANK NAILS. USE SMOOTH SHANK 5.4 - METAL PLATE-CONNECTED WOOD TRUSSES
10. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR PROVIDING A SAFE PLACE TO WORK AND MEETING NAILS AT WALLS.
THE REQUIREMENTS OF ALL APPLICABLE JURISDICTIONS. EXECUTE WORK TO ENSURE THE SAFETY 1. FRAMING LUMBER: DOUGLAS FIR (COAST REGION) GRADED AND MARKED IN ACCORDANCE WITH THE b. USE OF MACHINE NAILING IS SUBJECT TO A SATISFACTORY JOB SITE 1. DESIGN TRUSS SYSTEM ACCORDING TO PROVISIONS OF "DESIGN SPECIFICATIONS FOR LIGHT METAL
OF PERSONS AND ADJACENT PROPERTY AGAINST DAMAGE BY FALLING DEBRIS AND OTHER STANDARD GRADING RULES NO. 17 OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB) OR DEMONSTRATION FOR EACH PROJECT AND APPROVAL BY THE OWNER'S PLATE CONNECTED WOOD TRUSSES", BY THE TRUSS PLATE INSTITUTE, UNO.
HAZARDS IN CONNECTION WITH THIS WORK. WESTERN LUMBER GRADING RULES, OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA). REPRESENTATIVE. NAIL HEADS THAT PENETRATE THE OUTER PLY MORE THAN 2. TRUSS DESIGN CRITERIA:
11. APPLY, PLACE, ERECT OR INSTALL ALL PRODUCTS AND MATERIALS IN ACCORDANCE WITH THE USE LUMBER OF THE FOLLOWING GRADES: WOULD BE NORMAL FOR A HAND HAMMER OR IF THE MINIMUM ALLOWABLE EDGE A. ROOF TRUSSES
MANUFACTURER'S INSTRUCTIONS. DISTANCES ARE NOT MAINTAINED THE INSTALLATION IS UNSATISFACTORY. a. DEAD LOAD 29 PSF TOTAL
MACHINE NAILING IS NOT APPROVED IN 5 16" OR LESS SHEATHING. A.1 TOP CHORD DEAD LOAD 14 PSF
MEMBER WOOD/GRADE 3. BOLT AND SCREW INSTALLATION: A.2 BOTTOM CHORD DEAD LOAD 15 PSF
2.0 - FOUNDATION AND SITE WORK DIMENSIONAL LUMBER (UNO) DF #2 A. DRILL BOLT HOLES A MAXIMUM OF 116" INCH LARGER IN DIAMETER THAN THE BOLT NOMINAL b. SNOW LOAD 25 PSF
1
DIAMETER. c. NET WIND UPLIFT 20 PSF (ASD)
BEAMS 5 2" AND WIDER DF #1
1. THE DESIGN OF THE FOUNDATION SYSTEM IS BASED UPON THE CRITERIA AND RECOMMENDATIONS B. DRILL PRE-BORED LEAD HOLES FOR WOOD SCREWS AS FOLLOWS. d. LIVE LOAD DEFLECTION L/360
1 DF #1
CONTAINED IN IBC 1806. BEAMS 4 2" AND NARROWER a. DRILL LEAD HOLE FOR THE SHANK TO A DEPTH EQUAL TO THE LENGTH OF THE e. DEAD LOAD DEFLECTION L/240
2. LOCATE AND PROTECT EXISTING UTILITIES TO REMAIN DURING AND/OR AFTER CONSTRUCTION. POSTS, 6X6 & LARGER DF #1 UNTHREADED PORTION IN THE MAIN MEMBER. USE A DRILL BIT 7 8" THE DIAMETER 3. PROVIDE TRUSS AND COMPRESSIVE MEMBER LATERAL BRACING AND CONNECTIONS FOR
3. REMOVE ABANDONED FOOTINGS, UTILITIES, ETC. WHICH INTERFERE WITH NEW CONSTRUCTION, OF THE WOOD SCREW. CONSTRUCTION AND PERMANENT LOADS, INCLUDING BRACING FOR WIND UPLIFT.
POSTS, 4X6 & SMALLER DF #1
UNO. b. EXTEND THE LEAD HOLE FOR THE THREADED PORTION OF THE SCREW WITH A 4. CONNECTION PLATE DESIGN: DEVELOP FULL DESIGN STRESS IN A MEMBER. PROVIDE A MINIMUM
BACKING, STRIPPING AND FURRING CONSTRUCTION DRILL BIT WHOSE DIAMETER IS 7 8" THE DIAMETER OF THE SCREW AT THE ROOT OF TRANSFER AT ANY MEMBER OF 2,000 POUNDS.
4. NOTIFY THE OWNER'S REPRESENTATIVE IF ANY BURIED STRUCTURES NOT INDICATED, SUCH AS
CESSPOOLS, CISTERNS, FOUNDATIONS, ETC., ARE FOUND. THE THREAD. 5. SHOP DRAWINGS:
5. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR EXCAVATION PROCEDURES INCLUDING LAGGING, 2. MAXIMUM MOISTURE CONTENT: 19% c. INSERT THE SCREW INTO LEAD HOLE BY TURNING. DO NOT DRIVE WITH A HAMMER. A. INCLUDE ERECTION PLAN SHOWING LATERAL BRACING FOR TRUSS COMPRESSIVE
SHORING, UNDERPINNING AND PROTECTION OF EXISTING CONSTRUCTION. 3. PROVIDE SOLID BLOCKING (SAME DEPTH OF MEMBER) AT ALL POINTS OF BEARING (MAXIMUM d. LUBRICATE WITH SOAP OR BEESWAX TO FACILITATE INSTALLATION. MEMBERS AND REQUIRED BRACING CONNECTIONS.
6. MECHANICALLY COMPACT EXCAVATION BACKFILLS TO 95% OF MODIFIED PROCTOR IN LIFTS OF 8 SPACING OF 8'-0" OC) AT JOIST WITH A 5:1 OR GREATER DEPTH-TO-THICKNESS RATIO OR WHERE 1 C. DRILL PRE-BORED LEAD HOLES FOR LAG SCREWS AS FOLLOWS: B. SUBMIT TRUSS DESIGN CALCULATIONS SHOWING MEMBER FORCES AND COMBINED
INCHES IN HEIGHT MAXIMUM. PROVIDE COMPACTION IN ACCORDANCE WITH THE ASTM D1557 TEST EDGE OF JOIST IS NOT ATTACHED TO SHEATHING, WALLBOARD, BRACING, ETC. a. DRILL LEAD HOLE FOR THE SHANK TO A DEPTH EQUAL TO THE LENGTH OF THE STRESSES. CALCULATIONS SHALL BE STAMPED BY A REGISTERED CIVIL ENGINEER IN THE
METHOD. VERIFY ADEQUACY OF STRUCTURAL FILL COMPACTION WITH RANDOM FIELD DENSITY 4. PLATES AND LEDGERS USED IN INTERIOR CONDITIONS (LUMBER AND FASTENERS ARE INSIDE OR UNTHREADED PORTION IN THE MAIN MEMBER. USE A DRILL BIT OF THE SAME STATE OF OREGON.
TESTS. COMPACT STRUCTURAL TO 90% RELATIVE COMPACTION FILL WITHIN 5'-0" OF RETAINING OR CONCEALED BY MOISTURE BARRIER, ROOFING, ETC.) AND IN CONTACT WITH CONCRETE OR DIAMETER AS THE LAG SCREW. C. SUBMIT ICC APPROVAL INFORMATION.
BASEMENT WALLS WITH LIGHTWEIGHT, HAND-HELD EQUIPMENT. EXERCISE CARE TO AVOID MASONRY SHALL BE PRESSURE TREATED LUMBER. b. EXTEND THE LEAD HOLE FOR THE THREADED PORTION OF THE LAG SCREW WITH A D. SUBMIT SHOP DRAWINGS TO AHJ FOR REVIEW.
DAMAGE TO WALLS AND FOUNDATIONS. PLACE FOOTINGS ON COMPACTED STRUCTURAL FILL. 5. BEAMS, JOIST, POSTS, PLATES AND LEDGERS USED FOR EXTERIOR CONDITIONS (EXPOSED TO DRILL BIT WHOSE DIAMETER IS 60% OF THE NOMINAL LAG SCREW DIAMETER. 6. CONNECT TRUSSES TO SUPPORTING MEMBERS FOR CALCULATED LOADINGS.
7. LOCATE BOTTOM OF FOOTINGS AT A MINIMUM OF 1'-6" BELOW FINAL GRADE AT EXTERIOR EXTERIOR ENVIRONMENT IN ANY CIRCUMSTANCE) SHALL BE PRESSURE TREATED LUMBER. ENDS c. INSERT LAG SCREW INTO LEAD HOLE BY TURNING. DO NOT DRIVE WITH A HAMMER. 7. PROVIDE DOUBLE TRUSSES ADJACENT TO ANY OPENING EXCEEDING 4'-0".
LOCATIONS, 1'-0" BELOW FINAL GRADE AT INTERIOR LOCATIONS, OR 1'-0" BELOW EXISTING GRADE, OF FIELD CUT PRESSURE-TREATED WOOD SHALL CONFORM TO AMERICAN WOOD PROTECTION LUBRICATE WITH SOAP OR BEESWAX TO FACILITATE INSTALLATION.
WHICHEVER IS DEEPER. ASSOCIATION (AWPA) STANDARD M4 FOR STANDARD OF CARE WHERE WATER EXPOSURE IS LIKELY. 4. FRAMING CONNECTORS: SIMPSON STRONG-TIE OR APPROVED. 6.0 - STRUCTURAL TESTS, INSPECTIONS, AND OBSERVATIONS
8. PRIOR TO PLACEMENT OF CONCRETE, REMOVE ALL DISTURBED SOIL FROM FOOTING EXCAVATION 6. PROVIDE BLOCKING BETWEEN STUDS (OR OTHER MEANS OF BRACING) AT WOOD BEARING WALLS TO C. FILL ALL NAIL HOLES WITH NAILS AS SPECIFIED BY THE CONNECTOR MANUFACTURER, UNO.
TO NEAT LINES. REMOVE STANDING WATER FROM FOUNDATIONS PRIOR TO PLACING CONCRETE. PREVENT STUD BUCKLING PRIOR TO INSTALLATION OF GYPSUM WALLBOARD. D. CONNECTIONS IN CONTACT WITH PRESSURE-TREATED LUMBER SHALL BE HOT-DIPPED 1. AN INDEPENDENT TESTING AGENCY AND SPECIAL INSPECTORS WILL BE RETAINED BY THE OWNER
9. STEP BOTTOM OF FOOTINGS FROM ELEVATION TO ELEVATION AT A RATIO OF 1 VERTICAL TO 2 7. DO NOT USE WOOD SHINGLE SHIMS UNDER STUDS, JOISTS, BEAMS, OR POSTS. ZINC-COATED GALVANIZED. TO PERFORM TESTS AND INSPECTIONS AS SHOWN ON SHEET S0.3. PROVIDE ACCESS AND FURNISH
HORIZONTAL, WITH A MAXIMUM VERTICAL STEP OF 2'-0". 8. PANEL SHEATHING: IDENTIFY WOOD STRUCTURAL PANELS WITH THE APPROPRIATE TRADEMARK OF 5. ANCHOR ALL PLATES AND LEDGERS WITH A MINIMUM OF 3 ANCHORS PER PIECE. SAMPLES TO THE AGENCY AS REQUIRED BY THE CONTRACT DOCUMENTS.
. APA-THE ENGINEERED WOOD ASSOCIATION AND MEET THE REQUIREMENTS OF THE VOLUNTARY 6. MAXIMUM SPACING OF WOOD PLATE OR LEDGER CONNECTIONS SHALL BE 4'-0" OC, UNO. 2. IF INITIAL TESTS OR INSPECTIONS MADE BY THE OWNER'S TESTING AGENCY REVEAL THAT ANY
3.0 - FORMWORK PRODUCT STANDARD PS-1-95 AND APA PRP-108 PERFORMANCE STANDARD. A. PLACE ANCHOR 1'-0" FROM SPLICE OR END OF MEMBER. PORTION OF THE WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS, ADDITIONAL TESTS,
A. PANEL SHEATHING SHALL BE EXPOSURE 1. INSPECTIONS, AND NECESSARY REPAIRS WILL BE MADE AT THE CONTRACTOR'S EXPENSE.
1. REFERENCE STANDARDS (CURRENTLY ADOPTED EDITIONS) B. PLYWOOD PANELS SHALL BE 5-PLY MINIMUM. 3. THE ITEMS IDENTIFIED IN THE FOLLOWING TABLE REQUIRE TESTS AND INSPECTIONS IN
A. ACI 301 SECTION 2 "FORMWORK AND ACCESSORIES". C. PLYWOOD SHALL BE CC GRADE AT LOCATIONS EXPOSED TO WEATHER; CD GRADE ACCORDANCE WITH THE "STRUCTURAL TESTS AND INSPECTIONS" REQUIREMENTS OF THE CODE
2. PROVIDE POUR POCKETS IN FORMS AND UNDER EXISTING STRUCTURAL MEMBERS AS REQUIRED TO ELSEWHERE. OF THE GOVERNING JURISDICTION AS NOTED.
PREVENT AIR POCKETS AND/OR "HONEYCOMB" UNDER OR AROUND THE EXISTING MEMBERS. 9. SUBSTITUTION OF ORIENTED STRAND BOARD (OSB) FOR PLYWOOD IS ACCEPTABLE IF THE OSB:
CONCRETE CAST WITH AIR POCKETS AND/OR "HONEYCOMB" UNDER OR AROUND THE MEMBERS IS A. CONFORMS WITH APA PERFORMANCE STANDARDS FOR WOOD BASED STRUCTURAL USE
NOT ACCEPTABLE. PANELS PRP-108 AND UNITED STATES PRODUCT STANDARD PS2-92.
3. REMOVE FORMS AND SHORES NO SOONER THAN 48 HOURS AFTER PLACEMENT. B. IS MANUFACTURED WITH EXTERIOR GLUE.
C. HAS A LOAD/SPAN RATING INDEX EQUAL TO PLYWOOD.
D. BEARS THE APA TRADEMARK.
3.1 - REINFORCING STEEL 10. PROVIDE PRESSURE-TREATED PLYWOOD WHERE INDICATED ON DRAWINGS. CONFORM WITH AWPA
STANDARD C11. MARK SHEETS WITH AWPB.
1. REFERENCE STANDARDS (CURRENTLY ADOPTED EDITIONS) 11. PLYWOOD LAYOUT AND INSTALLATION:
A. ACI 301 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE", SECTION 3 A. LAY OUT PLYWOOD SHEATHING WITH END JOINTS STAGGERED, UNLESS NOTED OTHERWISE.
"REINFORCEMENT AND REINFORCEMENT SUPPORTS". B. LAY OUT PLYWOOD TO ELIMINATE WIDTHS LESS THAN 1'-0" AT ROOFS, OR LESS THAN 2'-0"
B. ACI SP-66 "ACI DETAILING MANUAL" INCLUDING ACI 315 "DETAILS AND DETAILING OF AT FLOORS, UNLESS ALL EDGES OF UNDERSIZED PIECES ARE SUPPORTED BY BLOCKING.
CONCRETE REINFORCEMENT". C. PROVIDE PANEL SPACINGS ACCORDING TO APA RECOMMENDATIONS.
C. CRSI MSP-1 "MANUAL OF STANDARD PRACTICE". D. IMMEDIATELY PRIOR TO PLACING FLOOR SHEATHING PANELS, APPLY A 1 4" DIAMETER INSPECTION TASKS
D. ANSI/AWS D1.4 "STRUCTURAL WELDING CODE - REINFORCING STEEL". CONTINUOUS BEAD OF CONSTRUCTION ADHESIVE, CONFORMING WITH AFG-01, TO TOPS OF
E. IBC CHAPTER 19, "CONCRETE". ALL JOISTS, BLOCKING AND PLATES.
F. ACI 318 AND ACI 318R. "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE". E. BLOCK SHEAR WALL SHEATHING WITH 3 X 4 FLAT BLOCKING AT ALL EDGES. INSPECTION TASKS AND DOCUMENTATION FOR SPECIAL INSPECTION SHALL BE PROVIDED BY THE QUALITY
G. ACI 315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" F. PROTECT FLOOR AND ROOF SHEATHING FROM EXTREME WET CONDITIONS. ASSURANCE SPECIAL INSPECTOR AS SHOWN IN TABLE 1. THE FOLLOWING ENTRIES ARE USED IN THE
2. ALL REINFORCING SHALL CONFORM TO ASTM A615, 60 KSI, UNO. G. NAIL ACCORDING TO SCHEDULE AND DRAWINGS. TABLES:
3. ACCURATELY POSITION, SUPPORT, AND SECURE REINFORCEMENT FROM DISPLACING DUE TO 12. ANCHOR BOLTS: ASTM A307 OR ASTM A36, UNO. DATE: 3/13/2022
FORMWORK, CONSTRUCTION, OR CONCRETE PLACEMENT OPERATIONS. LOCATE AND SUPPORT CONTINUOUS: THE INSPECTOR SHALL BE IN THE AREA OF WORK FULL-TIME, AND SHALL INSPECT IN A
REINFORCING BY METAL CHAIRS, RUNNERS, BOLSTERS, SPACERS, AND HANGERS AT A MAXIMUM 5.1 - FRAMING CONNECTORS TIMELY MANNER.
3-FOOT SPACING.
4. TERMINATE REINFORCING STEEL WITH STANDARD HOOKS, UNLESS OTHERWISE SHOWN. 1. ROUGH HARDWARE: PERIODIC: THE INSPECTOR SHALL BE PRESENT IN THE AREA OF WORK PART-TIME. THE INSPECTOR MUST PRINT:
5. PROVIDE REINFORCING SHOWN OR NOTED IN CONTINUOUS LENGTHS AS LONG AS PRACTICABLE. A. NAILS: COMMON WIRE NAILS, FEDERAL SPECIFICATION FF-N-105B, STANDARD LENGTHS BE PRESENT INTERMITTENTLY DURING THE WORK, AND AT THE COMPLETION OF THE WORK.
6. TYPICAL REINFORCING (MINIMUM, UNO ON DRAWINGS): UNO. USE HOT-DIPPED ZINC-COATED GALVANIZED NAILS FOR EXTERIOR INSTALLATIONS
A. CORNERS AND INTERSECTIONS OF WALLS AND FOUNDATIONS: CORNER BARS EQUAL IN AND WHEN IN CONTACT WITH PRESSURE TREATED OR FIRE-RETARTANT LUMBER.
SIZE AND NUMBER T0 HORIZONTAL REINFORCING LEG LENGTH: 48 BAR DIAMETER (2'-0" B. BOLTS AND THREADED RODS: ASTM A307, HEXAGONAL HEAD MACHINE BOLTS WITH ASTM
MINIMUM). A563 NUTS. USE MALLEABLE IRON WASHERS UNDER HEAD AND NUT WHEN IN CONTACT TABLE 1
8. DO NOT DISPLACE, WELD, HEAT OR CUT REINFORCING UNLESS INDICATED ON THE DRAWINGS, OR WITH WOOD. SIGNATURE:
APPROVED BY STRUCTURAL ENGINEER OF RECORD. C. LAG SCREWS: ASTM A307, ANSI/ASME STANDARD B18.2.1. USE ANSI B18.22.1 WASHERS REQUIRED STRUCTURAL SPECIAL INSPECTIONS
9. LAP SPLICE: UNDER HEAD WHEN IN CONTACT WITH WOOD.
D. SCREWS: ASTM A307, ANSI/ASME STANDARD B18.6.1. USE CADMIUM-PLATED PAN OR ROUND
INSPECTION

LAP SPLICE LENGTHS (INCHES)1,2 HEADED SCREWS AT STEEL-TO-WOOD AND WOOD-TO-WOOD CONNECTIONS. SYSTEM or MATERIAL IBC CODE CODE or STANDARD FREQUENCY REMARKS
GRADE 60 REINFORCING BARS, NORMAL WEIGHT CONCRETE E. MISCELLANEOUS STEEL: ASTM A36. REFERENCE REFERENCE Continuous Periodic
F. BOLTS, NUTS, WASHERS, STRAPS AND OTHER HARDWARE EXPOSED TO THE WEATHER
BAR SIZE #3 #4 #5 #6 #7 #8 #9 #10 #11 SHALL BE HOT-DIPPED GALVANIZED OR STAINLESS STEEL. CONCRETE DATE:
TOP BAR3 28 38 47 56 81 93 105 118 131 G. ANCHOR BOLTS: ASTM A307 OR ASTM A36, UNO.
SPECIAL INSPECTIONS APPLY TO ANCHOR PRODUCT
f'c = 3000 PSI H. UNO, FRAMING CONNECTIONS SHALL COMPLY WITH THE FOLLOWING NAILING SCHEDULE: NAME, TYPE, AND DIMENSIONS, HOLE DIMENSIONS,
OTHER BAR 22 29 36 43 63 72 81 91 101
COMPLIANCE WITH DRILL BIT REQUIREMENTS,
NOTES: INSPECTION OF ANCHORS INSTALLED IN 1909.1 ACI 318:
X CLEANLINESS OF THE HOLE AND ANCHOR,
1. LAP SPLICE LENGTHS, WHERE PERMITTED, SHALL BE IN ACCORDANCE WITH HARDENED CONCRETE TABLE 1705.3 3.8.6, 8.1.3, 21.1.8
ADHESIVE EXPIRATION DATE, ANCHOR/ADHESIVE
THIS TABLE UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE. INSTALLATION, ANCHOR EMBEDMENT, AND DRAWN BY: LARS WYATT
2. EMBEDMENT LENGTHS OF DOWELS SHALL BE EQUAL TO LENGTHS FOR "OTHER TIGHTENING TORQUE
BARS. 1705.3 TOLERANCES AND REINFORCING PLACEMENT PER
3. TOP BARS ARE HORIZONTAL BARS SO PLACED THAT MORE THAN 12 INCHES OF ACI 318: 3.5
REINFORCING STEEL PLACEMENT 1910.4 X ACI 7.5; SPACING LIMITS FOR REINFORCING ACI 7.6
CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. ACI 318: 7.1-7.7
1901.3.2 PROTECTION OF REINFORCEMENT PER ACI 7.7
TABLE ACI 318: 1.3.2.D
SCALE:
3.2 - CAST-IN-PLACE CONCRETE CONCRETE PLACEMENT X
1705.3 ACI 318: 5.9 - 5.10
SPECIAL INSPECTIONS APPLY TO SHAPE, LOCATION

N/A
1. REFERENCE STANDARDS (CURRENTLY ADOPTED EDITIONS) TABLE
VERIFICATION OF FORMWORK ACI 318: 6.1.1 X AND DIMENSIONS OF THE CONCRETE MEMBER
A. ALL CONCRETE SHALL BE MIXED AND PLACED IN ACCORDANCE WITH ACI 318-08. 1705.3
BEING FORMED
B. ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE".
C. IBC CHAPTER 19 "CONCRETE". POST INSTALLED CONCRETE ANCHORS
SPECIAL INSPECTIONS APPLY TO ANCHOR
PRODUCT NAME, TYPE, AND DIMENSIONS, HOLE
ICC EVALUATION
1705.1.1 DIMENSIONS, COMPLIANCE WITH DRILL BIT
INSPECTION OF ANCHORS INSTALLED IN REPORT
HARDENED CONCRETE
TABLE
1705.3
ACI 318:
X REQUIREMENTS, CLEANLINESS OF THE HOLE AND
ANCHOR, ADHESIVE EXPIRATION DATE,
SHEET No.:
3.8.6, 8.1.3, 21.1.8
ANCHOR/ADHESIVE INSTALLATION, ANCHOR

S01
EMBEDMENT, AND TIGHTENING TORQUE
(S) RPS18 (S) MSTC W/
SHEAR WALL SCHEDULE 2x STUD, SEE 2x TOP PLATE, (36) 16d AT 24" CLR,
PLAN, TYP TYP (44) 16d AT 18" CLR,
PANEL NAILING BOT PL (S) RPS28 W/ & (48) 16d AT 16" CLR
MARK SHTHG SIDE NAILING TO PANEL SILL AB RIM JST VALUE
WOOD BELOW BLKG PL (MIN 7" EMBED) ABOVE (PLF) (16) 16d
SIZE EDGE FIELD

A 7/16" APA RATED 3x (2) 16d


SHTHG WITH ONE 8d 6" OC 12" OC 16d AT 6" OC 2x 5/8" x 10" AT 48" OC TOENAIL 280
STUDS AT 16" OC (2) 2x AT 8" OC
(S) CTS218
B 7/16" APA RATED 3x (S) LTP4
SHTHG WITH ONE 8d 4" OC 12" OC 16d AT 4" OC 3x 5/8" x 12" AT 42" OC OR A35 AT 430 09-30-2022
STUDS AT 16" OC (2) 2x 20" OC

C 7/16" APA RATED 3x


(S) LTP4 WATER
SHTHG WITH ONE 8d 3" OC 12" OC 16d AT 3" OC 3x 5/8" x 12" AT 36" OC 550
AT 16"
STUDS AT 16" OC (2) 2x
OC
OR VENT
PIPE BY
D 7/16" APA RATED 3x (S) OTHERS NOTE:
SHTHG WITH ONE 10d 2" OC 12" OC 16d AT 2" OC 3x 5/8" X 12" AT 24" OC LTP4 870 1. CENTER ALL HARDWARE ON MECHANICAL/ELECTRICAL/
TO FLOOR
STUDS AT 16" OC (2) 2x AT 12" OC
ABOVE PLUMBING OPENINGS. LOCATION:
7/16" APA RATED 3x (S) 2. ALL HARDWARE LOCATED AT SILL PLATE, PT LUMBER,
E
SHTHG WITH TWO 8d 6" OC 12" OC 16d AT 3" OC 3x 5/8" X 12" AT 32" OC LTP4 EF 560 (S) NS1 OR EXPOSED TO MOISTURE OR EXTERIOR CONDITIONS
STUDS AT 16" OC (2) 2x AT 24" OC (S) SS1.5 TO HAVE (S) ZMAX COATING. 21541 YANKEE VALLEY ROAD
F 7/16" APA RATED
SHTHG WITH TWO 8d 4" OC 12" OC 16d AT 2" OC 3x
3x
5/8" x 12" AT 24" OC (S) LTP4 EF 860
(S) NS1 HIDDEN VALLEY LAKE, CA. 95467
STUDS AT 16" OC (2) 2x AT 20" OC

G 7/16" APA RATED (2) ROWS OF 3x (S) LTP4 EF


SHTHG WITH TWO 10d 2" OC 12" OC 3x 5/8" x 12" AT 12" OC AT 12" OC 1740
16d AT 3" OC
STUDS AT 16" OC (2) 2x
PROJECT:
NOTES: (S) HSS2- HVAC CHASE BY
SUPPLY SDS1.5 OTHERS AT
1. REFERENCE 1/S4 FOR SHEAR WALL ELEVATION (APPLY AT ALL SHEARWALL LOCATIONS). HVAC CHASE BY LINES
(2) ADJACENT
OTHERS IN EXTERIOR BY OTHERS
STUD BAYS
2. SOME SHEARWALLS LISTED MAY NOT BE USED IN THIS PROJECT. SEE PLAN FOR LOCATIONS AND REQUIREMENTS. OR LOAD BEARING WALL
3. 8d NAIL = 2 21 " x 0.131" COMMON OR 2 21" x 0.113" GALVANIZED BOX. (S) HSS2-3-SDS1.5
10d NAIL = 3" x 0.148" COMMON OR 3" x 0.128" GALVANIZED BOX. (S) NS1 (3) 16d NAILS AT
16" OC STAGGERED
4. IF ANCHOR BOLT SPACING IS GREATER THAN SHEARWALL LENGTH INSTALL (1) ANCHOR BOLT WITHIN 12" OF EACH END. ELECTRICAL WIRING EA SIDE OF
BY OTHERS, TYP OPENING
5. NAIL SIZES SHOWN ARE FOR COMMON NAILS OR GALVANIZED BOX. POWER DRIVEN NAILS SHALL COMPLY WITH ESR 1539 FOR RECOMMENDED SPACING AND NS1
(S) PSPN516Z LOAD BEARING WALL
INSTALLATION TO COMPLY WITH THE ABOVE SHEARWALL SCHEDULE.
(S) PSPN58Z (WITH HVAC CHASE
6. SILL PLATE ANCHORS SHALL INCLUDE A STEEL PLATE WASHER NOT LESS THAN 0.229"x3"x3" IN SIZE PER AF&PA SDPWS SECTION 4.3.6.4.3. THE HOLE IN THE BY OTHERS)
PLATE WASHER SHALL BE PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3 16" LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT
TO EXCEED 1 34 ", PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. THE PLATE WASHER SHALL EXTEND TO
(S) PS28 W/ (16) 16d
WITHIN 12" OF THE EDGE OF THE BOTTOM PLATE ON THE SIDE(S) WITH SHEATHING.

7. IN SEISMIC DESIGN CATEGORIES D, E, OR F, WHERE SHEAR DESIGN VALUES EXCEED 700 POUNDS PER LINEAR FOOT (350 PLF ASD), ALL FRAMING MEMBERS
RECEIVING EDGE NAILING FROM ABUTTING PANELS SHALL NOT BE LESS THAN A SINGLE 3" NOMINAL MEMBER, OR (2) 2" NOMINAL MEMBERS FASTENED FRAMING DETAILS FOR UTILITY PENETRATIONS
TOGETHER IN ACCORDANCE WITH SECTION 2306.1 TO TRANSFER THE DESIGN SHEAR VALUES BETWEEN FRAMING MEMBERS. WOOD STRUCTURAL PANEL
JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL CASES.
A SCALE: N.T.S.

8. WHERE PANELS ARE APPLIED TO BOTH FACES OF A WALL AND NAIL SPACING IS LESS THAN 6" OC ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL
ON DIFFERENT FRAMING MEMBERS. ALTERNATIVELY, THE WIDTH OF THE NAILED FACE OF FRAMING MEMBERS SHALL BE 3" NOMINAL OR GREATER AT
ADJOINING PANEL EDGES AND NAILS AT ALL PANEL EDGES SHALL BE STAGGERED.

9. SHEARWALL NAILING MUST BE INSTALLED SUCH THAT THE NAIL HEAD OR CROWN IS FLUSH WITH THE SURFACE OF SHEATHING. OVERDRIVEN OR OVER
PENETRATED NAILS WILL NOT BE ALLOWED OR COUNTED AS APPROPRIATE NAILING.
(S) A35 EA CORNER, TYP DBL TOP PL

HOLDOWN SCHEDULE
MARK HOLDOWN WOOD WOOD AB COMMENTS VALUE
AB
MEMBER FASTENER EMBED (IN) SEE NOTES BELOW (LBS)

NONE
0 REQUIRED HDR, SEE SCHED

WRAP & NAIL STRAP TO


(2) 2x (22) 16d NAILS N/A N/A 2,710 CRIPPLE
(S) MST37 BEAM/HEADER BELOW KING
1 1/2 T&B
AS REQUIRED
STUDS STUDS
TYP TYP
WRAP & NAIL STRAP TO
(2) 2x (32) 16d NAILS N/A N/A 4,205
(S) MST48 BEAM/HEADER BELOW
2 1/2 T&B
AS REQUIRED DBL BTM PL

WRAP & NAIL STRAP TO


(2) 2x (48) 16d NAILS N/A N/A 6,235
(S) MST60 BEAM/HEADER BELOW
3 1/2 T&B
AS REQUIRED

(S) (2) 2x (8) (S) 1/2" DIA 7"


SDS SCREWS J-BOLT 1,450
4 DTT2Z-SDS2.5

(S) (2) 2x (6) (S) 5/8" DIA 12 5/8"


HDU2-SDS2.5 SDS SCREWS (S) SSTB16 3,075
5

STUDS SEE PLAN


(S) (2) 2x (14) (S) 5/8" DIA 16 5/8"
SDS SCREWS (S) SSTB20 4,040 (S) A35 EA CORNER, TYP BTM PL
6 HDU4-SDS2.5

(S) (2) 2x (14) (S) 5/8" DIA 18"


7 HDU5-SDS2.5 SDS SCREWS (S) SB 5/8"x24" 5,645 HEADER SCHEDULE
OPEN WIDTH CRIPPLE STUDS KING STUDS HEADER
HEADER CONN
WINDOW SILL PL DATE: 3/13/2022
TO TRIM STUDS
(S) (1) 4x (20) (S) 7/8" DIA 18" (4) 16d NAILS
SDS SCREWS (S) SB 7/8"x24" 6,970 UP TO 4'-0" (1) 2x (2) 2x 4x6 (1) 2x
8 HDU8-SDS2.5
EA SIDE
UP TO 6'-0" (1) 2x (2) 2x 4x8
(4) 16d NAILS
(1) 2x
PRINT:
(S) (1) 6x (24) (S) (S) SB 1"x30" 24" EA SIDE
11,810
9 HHDQ11-SDS2.5 SDS SCREWS (S) ST2115
UP TO 9'-0" (2) 2x (3) 2x 6x10 (2) 2x
EA SIDE
(S) ST21154
(S) (1) 6x (30) (S) (S) PAB8 de= 11" UP TO 11'-0" (2) 2x (4) 2x 6x12 (4) 2x
10 HHDQ14-SDS2.5 SDS SCREWS W = 33" 13,710 EA SIDE
SIGNATURE:
NOTE:
(S) (1) 6x (36) (S) (S) PAB8 de = 11" TYPICAL OPENING FRAMING REQUIREMENTS DO NOT APPLY TO GARAGE DOOR
SDS SCREWS W = 33" 14,445
11 HDU14-SDS2.5
OPENINGS. SEE TYPICAL GARAGE PIER ELEVATION FOR ADDITIONAL
INFORMATION AND REQUIREMENTS FOR GARAGE OPENINGS.
NOTES:

1. NOT ALL HOLDOWNS IN TABLE ARE USED. SEE PLAN FOR LOCATIONS AND REQUIREMENTS. TYPICAL OPENING FRAMING DATE:
B SCALE: N.T.S.
2. SEE DETAIL 1/S4 FOR TYPICAL SHEAR WALL AND HOLDOWN ELEVATION.

3. DOUBLE STUDS ARE REQUIRED AT HOLDOWNS, UNO. DOUBLE STUDS SHALL BE LAMINATED TOGETHER WITH 16d NAILS AT 6" OC FULL HEIGHT (TYPICAL).

4. PROVIDE HOLDOWN NOTED WITHIN 6" FROM EACH END OF EACH SHEARWALL SHOWN ON PLANS.
DRAWN BY: LARS WYATT
5. INSTALL ANCHORS PER MANUFACTURER RECOMMENDATIONS.

ROOF FRAMING PLAN


6. ADJUST FOOTING AND STEM WALL HEIGHT TO ACCOMMODATE ANCHOR BOLT EMBEDMENT REQUIREMENTS PER MANUFACTURER RECOMMENDATIONS.

7. ALL HOLDOWN ANCHORS AND BOLTS SHALL BE INSTALLED IN THE CORRECT LOCATION IN THE TOP OF THE CONCRETE WALL AND SECURED TO THE
FORMS PRIOR TO CONCRETE INSTALLATION. THERE IS NO PRACTICAL SOLUTION TO POST-INSTALLED HOLDOWN ANCHORS IN THE TOP OF THE
SCALE:
CONCRETE STEM WALL. NO EPOXY OR MECHANICAL ANCHOR BOLT ALTERNATIVES WILL BE OFFERED FOR MISSING OR MISPLACED EMBEDDED
ANCHORS. CONCRETE FOOTINGS AND STEM WALLS MAY HAVE TO BE REMOVED AT CONTRACTOR'S EXPENSE TO MITIGATE MISPLACED, MISALIGNED, OR
SCALE 1/4" = 1'-0"
AS NOTED
MISSING HOLDOWN ANCHORS OR BOLTS.

8. WHERE SUB-FLOOR WALLS ARE PRESENT, HOLD-DOWNS SHALL CONNECT FLOOR-LEVEL WALLS TO SUB-FLOOR-LEVEL WALLS IN ADDITION TO
CONNECTING INTO THE FOUNDATION; REFER 11/S4 FOR HOLD-DOWN INFO.

SHEET No.:

S02
09-30-2022

6
S3

LOCATION:

21541 YANKEE VALLEY ROAD


HIDDEN VALLEY LAKE, CA. 95467

PROJECT:
9
S3
6
S3

12 8
S3 S3
B B 4x6 POST W/ (S)
4x6 POST W/ (S)
5 5 ABU POST BASE
ABU POST BASE

4x6 POST CONTINUOUS TO


ROOF W/ (S) ABU POST BASE
S S 2'-0" SQ x 12" CONC FTG W/ 2'-0" SQ x 12" CONC FTG W/
(4) #4 EA WAY (4) #4 EA WAY 7
S4
INDICATES APPROXIMATE LOCATION OF FOOTING STEP PER 6/S6.
LOCATION OF FOOTING STEPS TO BE DETERMINED BASED ON
GROUND CONDITIONS AND SUBMITTED FOR STRUCTURAL
ENGINEER'S REVIEW PRIOR TO CONSTRUCTION.

EQ
S
NOTE: STEP LOCATIONS MUST NOT OCCUR WITHIN A SHEAR WALL A
UNLESS PRIOR APPROVAL IS GIVEN BY STRUCTURAL ENGINEER.
5

B
8

EQ
S

2'-0" SQ x 12" CONC FTG


W/ (3) #4 EA WAY, TYP
4x4 FOR POSTS UP TO 8'-0" 4x6 POST, TYP
4x6 FOR POSTS UP TO 12'-0"
2'-0" SQ x 12" CONC FTG
W/ (3) #4 EA WAY, TYP

10
S
S3 8'-0" TYP

5 B
S3 7 DATE: 3/13/2022

EQ
1'-6" x 12" CONT FTG W/ (2) #4
CONT BARS, TYP PRINT:
12 12
S3 S4
S S S
SIGNATURE:
4x6 POST CONTINUOUS TO
ROOF W/ (S) ABU POST BASE
A A 1'-6" x 12" CONT FTG W/
(2) #4 CONT BARS, TYP
1 1
SHEAR WALL OCCURS EACH 12 DATE:
SIDE OF FOOTING STEP S3

DRAWN BY: LARS WYATT

FOUNDATION & SUB-FLOOR PLAN SCALE:

SCALE 1/4" = 1'-0"


GENERAL FRAMING NOTES:

1. ALL GRADING AND DRAINAGE DESIGN IS BY OTHERS.


AS NOTED
2. ALL CIVIL ENGINEERING AND SLOPE STABILITY IS BY OTHERS.

3. ALL FOOTINGS ARE TO BE CONSTRUCTED ON STABLE GROUND SLOPED NO MORE THAN 1H:4V.
SHEET No.:
4. ALL EXTERIOR WALLS AND ALL BEARING/SHEAR WALLS SHALL BE 2x6 STUDS AT 16" OC. ALL NON-BEARING WALLS SHALL BE 2x STUDS AT 24" OC.

S1
5. HEIGHT OF SUB-FLOOR STUDS SHALL NOT EXCEED 12'-0".

INDICATES LOAD-BEARING WALL

INDICATES NON-LOAD-BEARING WALL

INDICATES SHEAR WALL


09-30-2022

6
S4
B B
5 5 LOCATION:

21541 YANKEE VALLEY ROAD


HIDDEN VALLEY LAKE, CA. 95467

PROJECT:
9
4" CONCRETE SLAB ON GRADE S4
6 W/ #4 AT 18" OC EA WAY

S4

A
5

12 8
S4 S4
B 4x6 POST
B
4x6 POST
4 4

4x4 POST CONTINUOUS TO


ROOF W/ (S) ABU POST BASE

7
S4
3
4" PLYWOOD SHEATHING W/
10d AT 6" OC AT PANEL EDGES
AND 12" OC IN THE FIELD.
A
4

B
1178"TJI-210 FLOOR 2x10 JOIST @ 16" OC,
5 JOIST @ 16" OC, TYP TYP AT PORCH

4x8 BEAM, TYP


POST BELOW, TYP 4x4 POST BELOW, TYP
4x10 BEAM, TYP 2'-0" SQ x 12" CONC FTG
W/ (3) #4 EA WAY, TYP

10
S4
5 B
S4 5 MIN 2x DECKING BY OTHERS
DATE: 3/13/2022

PRINT:
12 12
S4 S4

SIGNATURE:
4x4 POST CONTINUOUS TO
A ROOF W/ (S) ABU POST BASE

0
12 DATE:
S4

DRAWN BY: LARS WYATT

FLOOR PLAN SCALE:

SCALE 1/4" = 1'-0"


GENERAL FRAMING NOTES:

1. ALL EXTERIOR WALLS AND ALL BEARING/SHEAR WALLS SHALL BE 2x6 STUDS AT 16" OC. ALL NON-BEARING WALLS SHALL BE 2x STUDS AT 24" OC.
AS NOTED
2. ALL EXTERIOR WALLS TO MEET TYPE 'A' SHEAR WALL REQUIREMENTS, UNO. SEE SHEAR WALL SCHEDULE.

3. WHERE NON-STRUCTURAL WALLS ARE PARALLEL TO FLOOR JOISTS, LOCATE (1) JOIST BELOW WALL.
SHEET No.:
4. WHERE NON-STRUCTURAL WALLS ARE PERPENDICULAR TO FLOOR JOISTS, PROVIDE FULL-DEPTH SOLID BLOCKING AT 24" OC ALONG FULL LENGTH OF WALL.

S2
5. WHERE SUB-FLOOR WALLS ARE PRESENT, HOLD-DOWNS SHALL CONNECT FLOOR-LEVEL WALLS TO SUB-FLOOR-LEVEL WALLS IN ADDITION TO CONNECTING
INTO THE FOUNDATION; REFER 11/S4 FOR HOLD-DOWN INFO.

INDICATES LOAD-BEARING WALL

INDICATES NON-LOAD-BEARING WALL

INDICATES SHEAR WALL


09-30-2022
9
S5

LOCATION:

21541 YANKEE VALLEY ROAD


(S) CCQ POST CAP,
HIDDEN VALLEY LAKE, CA. 95467
TYP AT GARAGE BEAM

PRE-MANUFACTURED
PROJECT:
ROOF TRUSS @ 24" OC
8
514" X 1178" 2.2E PSL GARAGE BEAM
S5

8
S5

8
S5 11
S5
POST CAP PER GIRDER
TRUSS MFR, TYP

11 PRE-MANUFACTURED GIRDER 4x8 PORCH BEAM


TRUSS, ALIGN W/ INTERIOR WALL
S5

(S) BC POST CAP

10
S5
PRE-MANUFACTURED DRAG TRUSS, ALIGN
W/ INTERIOR WALL. TRUSS MFR TO DESIGN OUTERMOST TRUSS ALIGNS
FOR 8000# DRAG LOAD (ASD) WITH TIMBER POST

1
S6

PRE-MANUFACTURED
ROOF TRUSS @ 24" OC

9
S5

2 5
8" T&G PLYWOOD SHEATHING W/

S6 10d AT 6" OC AT PANEL EDGES


AND 12" OC IN THE FIELD. DATE: 3/13/2022

PRE-MANUFACTURED DRAG TRUSS, ALIGN PRINT:


W/ INTERIOR WALL. TRUSS MFR TO DESIGN
FOR 8000# DRAG LOAD (ASD)

HEADER PER SCHEDULE, TYP


SIGNATURE:
(S) BC POST CAP

DATE:
8
S5

DRAWN BY: LARS WYATT

ROOF FRAMING PLAN SCALE:

SCALE 1/4" = 1'-0"

GENERAL FRAMING NOTES:


AS NOTED
1. ROOF TRUSS MANUFACTURER TO CARRY OUT DESIGN FOR ALL TRUSSES (INCLUDING GIRDER TRUSS AND DRAG TRUSSES)

2. PROVIDE MIN (2) 2x STUDS BELOW ENDS OF ALL GIRDER TRUSSES AND DRAG TRUSSES, UNO)
SHEET No.:
INDICATES LOAD-BEARING WALL BELOW

S3
INDICATES NON-BEARING SHEAR WALL BELOW
SHORT BEND 6d GREATER THAN 3"
R = 3d FOR #3 THRU #8
S 135°
4d FOR #9 THRU #11 24 BAR 24 BAR
R = 2d FOR DIA DIA
1
5d FOR #14 & #18 4d (2 2" MIN) #3 THRU #5 R 09-30-2022
LONG BEND R = 3d FOR 90°
CLEAN GRANULAR

24 BAR
#6 THRU #8 10-MIL VAPOR BARRIER
R L= 8d FOR ALL BARS

DIA
MIN BAR SPACING: (NON-SPLICED MATERIAL BELOW SLAB
BARS) 1 12"OR 1 1/2d WHICHEVER IS CONC SOG, SEE PLAN
R 180° TIES & HOOPS LARGER 90° HKS W/ 24 DIA
R S
S EXTENSIONS
12d MIN

6d EQUAL OR
UNO

TURNED VERT
LOCATION:

2" MIN
90° d
GREATER THAN 2
1/2" FOR #3-#5 12d
LONG BEND, R L FOR #6-#8

2 1/2" MAX
TYP WALL REINF

1 1/2" MIN
90° 21541 YANKEE VALLEY ROAD
MAX BAR SPACING FOR
BENDS & STD HOOKS R= 2d FOR HIDDEN VALLEY LAKE, CA. 95467

MIN
NONCONTACT LAP SPLICES SEE ADD TRIM BARS TO

6"
#3 THRU #5 NOTE #3 MATCH WALL

4"
.
6 = 3d FOR REINF
1 #6 THRU #8
R
90° STD HK ROTATE TO PROVIDE
BAR OFFSETS 6d GREATER THAN MIN CLEARANCE CLEAN CRUSHED PROJECT:
2 12" FOR #3 THRU ROCK SEE GSN'S FOR SUBGRADE
2" CLR MAX (TO END OF HOOKED BARS ONLY)
#8 NOTES:
1" CLR MIN PREPARATION REQUIREMENTS
1. COLUMN DOWELS, TYPICAL HORIZONTAL WALL STEEL AND TYPICAL WALL STEEL
DOWELS MAY BE WIRED TOGETHER INSTEAD OF SPACING AS SHOWN ABOVE.
R 135° 2. CLEAR DISTANCE LIMITATION BETWEEN BARS SHALL APPLY ALSO TO THE CLEAR
90° DISTANCE BETWEEN A CONTACT LAP SPLICE AND ADJACENT SPLICES OF BARS.
STIRRUPS 3. BARS SPLICED BY NONCONTACT LAP SPLICES SHALL NOT BE SPLICED
NOTES:
TRANSVERSELY FURTHER APART THAT ONE-FIFTH THE REQUIRED LAP SPLICE NOTE:
LENGTH, NOR 6". SPLICES IN HORIZ REINFORCEMENT SHALL BE STAGGERED.
1. 'd' IS NOMINAL BAR DIAMETER
2. REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL
NOT BE FIELD BENT, UNLESS SPECIFICALLY NOTED ON THE
DRAWINGS.

HOOKS AND BENDS BAR SPACING WALL REINFORCEMENT AT CORNERS AND INTERSECTIONS TYP SUBGRADE PREP & SLAB ON GRADE DETAIL
1 SCALE: NTS 2 SCALE: NTS 3 SCALE: 1"=1'-0" 4 SCALE: 1"=1'-0"

SW SHTHG, SEE PLAN SW SHTHG, SEE PLAN


EN TO BLKG, SEE PLAN FLR JST SPLICE AS OCCURS AND SW SCHED AND SW SCHED
STUD WALL, SEE PLAN STUD WALL, SEE PLAN
FLR SHTHG, SEE PLAN JST CONNECTION TO BM PER
JST MANUF
SHEAR WALL, SEE SILL PL, RIP TO STEM SILL PL, RIP TO STEM
PLAN & SCHED WALL WIDTH, SEE SW WALL WIDTH, SEE SW
SCHED FOR REQ'S SCHED FOR REQ'S
EN, SEE SW SCHED EN, TYP EN, TYP
#4 HORIZ BARS FLR SHTHG, SEE PLAN FLR SHTHG, SEE PLAN
AT 18" OC. CONC SOG, SEE PLAN
SOG, SEE PLAN

12" MAX
6" MAX

12" MAX
1 12 LSL/LVL BLKG
12" MAX

EA, JOIST BAY FLR JST, SEE PLAN EXT GRADE


FINISHED GRADE
10d TOE NAIL AT
8" OC

BEAM, SEE PLAN (S) BC POST CAP FLR JST, SEE PLAN FLR JST, SEE PLAN
(PARALLEL AS OCCURS) (PARALLEL AS OCCURS)
POST, SEE PLAN #4 HORIZ AT 18" (BEAM AS OCCURS) #4 HORIZ AT 18" (BEAM AS OCCURS)
OC, TYP ADD FULL-DEPTH BLKG @ 32" OC OC, TYP ADD FULL-DEPTH BLKG @ 32" OC
1'-6"
MIN

(S) ABU POST BASE W/ 5 8" DIA WHEN JOISTS PARALLEL TO WALL WHEN JOISTS PARALLEL TO WALL

1'-6" MIN
6" 6"
MIN 12" INTO COMPACT OR

x 6" TITEN-HD ANCHOR

1'-6" MIN
(S) HU HANGER AT JOIST, (S) HGLT4 HANGER (S) ITS TOP FLANGE HANGER
UNDISTURBED EARTH

AT BEAM. PROVIDE 30# FELT PAPER, TYP WITH 30# FELT PAPER

#4 VERTS AT 48" #4 VERTS AT 48"


CLR

OC W/ STD HK OC W/ STD HK
3"

FTG PER PLAN (ALT DIRECTION), (ALT DIRECTION),


TYP TYP
EQ 6" EQ

FTG PER PLAN FTG PER PLAN FTG PER PLAN

ALTERNATE DIRECTION OF ALTERNATE DIRECTION OF


SEE GSN'S FOR SUBGRADE EACH HK, TYP EACH HK, TYP
PREPARATION REQUIREMENTS

POST FOOTING EXTERIOR STEM WALL AT GARAGE TYPICAL FOOTING DETAIL TRANSITION FOOTING DETAIL
5 SCALE: 1"=1'-0" 6 SCALE: 1"=1'-0" 7 SCALE: 1"=1'-0" 8 SCALE: 1"=1'-0"

11
STUD WALL, SEE PLAN WALL FRAMING PER
S5 PLAN FLR SHTHG, SEE PLAN DATE: 3/13/2022
SW SHTHG, SEE PLAN REFER PLAN FOR
HOLD-DOWN PER PLAN AS OCCURS HOLD-DOWN PER PLAN
GARAGE WALL AND SW SCHED SHEAR WALL LENGTH
AS OCCURS PRINT:
BEYOND
JOIN HOLD-DOWNS WITH THREADED ROD JOIN HOLD-DOWNS
EN, TYP WITH THREADED ROD SUB-FLOOR WALL
DOWELS W/ STD PT SILL AND
'd' SLAB DEPTH

HOOK TO MATCH ANCHORAGE, FLR SHTHG, SEE PLAN STUD WALL, FRAMING PER PLAN
FLR SHTHG, SEE PLAN
SEE PLAN

SEE PLAN

12'-0" MAX
SLAB REINF SEE SW SCHED

SLAB REINF
REFER PLAN FOR SUB-
FLR JST, SEE PLAN
SIGNATURE:
SEE PLAN FLOOR WALL LENGTH
(PARALLEL AS OCCURS)
TO GRADE (BEAM AS OCCURS)
OR SLAB ADD FULL-DEPTH BLKG @ 32" OC
HOLD-DOWN PER WHEN JOISTS PARALLEL TO WALL
CONT #4 WALL ABOVE

12" MAX
SW, MATCH WALL
FLR JST, SEE PLAN ABOVE EXT GRADE (S) HU HANGER AT JOIST, (S)
DATE:
MIN

SW, MATCH WALL ABOVE HGLT4 HANGER AT BEAM.


d

1 BUNDLED STUDS STUD WALL,


1'-6" MIN

1 BEAM PER PLAN, AS OCCURS OR POST MATCH WALL


STUD WALL, MATCH WALL ABOVE. ABOVE
PROVIDE 4x4 POST UNDER FLOOR
6" SEE GSN's FOR #4 HORIZ AT 18" OC, TYP
BEAMS AS OCCURS
SUBGRADE
PREPARATION HOLD-DOWN PER 6" DRAWN BY: LARS WYATT
WALL ABOVE

MIN 12" INTO COMPACT OR


REQUIREMENTS HOLD-DOWN AS PER WALL ABOVE

1'-6" MIN

UNDISTURBED EARTH
ANCHOR BOLT PER #4 VERTS AT 48"

ALT DIRECTION HOLD-DOWN SCHEDULE OC W/ STD HK


(ALT DIRECTION),
SCALE:
FTG PER PLAN
OF HK FTG PER PLAN TYP

NOTE:
OMIT WALL FRAMING AT GARAGE DOOR. ADD #3 HORIZ
FTG PER PLAN
FTG PER PLAN

ALTERNATE DIRECTION OF
AS NOTED
BARS & 48" OC EACH HK, TYP

FREE EDGE AT SLAB ON GRADE INTERIOR SHEAR WALL DETAIL HOLD-DOWN AT SUBFLOOR WALL CRIPPLE WALL DETAIL
9 SCALE: 1"=1'-0" 10 SCALE: 1"=1'-0" 11 SCALE: 1/2" = 1'-0" 12 SCALE: 1"=1'-0" SHEET No.:

S4
LENGTH, SEE PLAN DBL TOP PL
(S) HOLDOWN, SEE SW
SCHED TRIMMER STUD
EN, SEE SW SCHED, TYP
(AS REQD)
SILL PL, SEE SW
SCHED (2) 16d AT EQ EQ 09-30-2022
(2) 16d AT 8" OC,
FLOOR SHTG, SEE 8" OC, TYP
BLKG AT PANEL JOINTS, TYP
PLAN
EN SEE SW SCHED, TYP POST
HOLDOWN ANCHOR SEE
SEE SCHED PLAN

9"
HEIGHT, SEE PLAN

MIN (2) BOLTS IN


BUNDLED STUDS OR POST, SEE EA SILL SECT
HOLDOWN SCHED FOR SIZE.
((2) 2x MIN)
EDGE NAIL, TYP LOCATION:
SEE SW SCHED POST SEE
ENLARGED PLAN

ELEVATION WALL SHTHG, CORNER W/ POST INTERIOR W/ POST 21541 YANKEE VALLEY ROAD
WHERE SILL PL IS DRILLED OR
CON STEM WALL 5"
SEE SW SCHED
NOTCHED MORE THAN 1/3 OF THE
HIDDEN VALLEY LAKE, CA. 95467
SEE PLAN, TYP MIN PL WIDTH, INSTALL ONE BOLT
(2) 16d AT ES OF NOTCH
8" OC, TYP

9"
ANCHOR BOLT, SEE SW SCHED
FOR SPACING REQUIREMENTS, IF FLR SHTHG, EN TYP, SEE EDGE NAIL,
WALL SHTHG,
SPACING IS GREATER THAN SW
SEE SW SCHED
SEE PLAN SW SCHED TYP SEE PROJECT:
LENGTH, INSTALL AB WITHIN 12" SW SCHED
A
OF EA END.
RIM
9" 9" 9" 9" 9"
SEE ENLARGED ELEVATION
EN TYP, SEE CORNER W/O POST INTERIOR W/O POST
SW SCHED
NOTES: 5/8" DIA AB's AT 48" OC TYP,
1. SEE ON PLAN FOR SW LOCATIONS. SEE SW SCHED FOR OTHER
AB EMBEDMENT,
2. SEE SW SCHED AND PLAN FOR STUD REQ'S. SPACINGS AT SHEAR WALLS
SEE HOLDOWN
A SCHED PROVIDE JOIST TO ALIGN W/
HOLDOWN (AT PARALLEL
CONDITION, PROVIDE TIGHT
1 FIT BLKG)
1 12" 12" WALL CORNER DETAIL SILL PLATE ANCHORAGE
CLR

1 3/4" 2 3
3"

FLOOR JOIST 1 3/4" SCALE: N.T.S. SCALE: 1"=1'-0"


℄ HOLDOWN MIN
(PARALLEL AS MIN
ANCHOR OCCURS, CONC. SOG
AS OCCURS) SECTION A-A SECTION A-A (AT SIM)
TYPICAL SHEAR WALL ANDCLHOLDOWN ELEVATION
SPLICE IN EITHER TOP OR BOTTOM
1 SCALE: N.T.S. PLATE CENTER OVER STUD

16D 4'-0" LAP 4'-0" LAP 16D


AT 8"OC 16-16D 16-16D AT 8"OC

3" OC 1 12" NO NOTCHES OR


TYP HOLES PERMITTED 1" MIN 0.5d 1" MIN
WITHIN 'd' OF MAX
SUPPORT
MIN SPACING BTWN
'd' 'd' 't' 'd'/6 MAX
HOLES IS TWICE THE
MIN MIN DIA OF THE
(2) 2x TOP PLATES
EDGE NAIL EA (S) ST2215 LARGEST HOLE
ALTERNATIVE
2X, TYP ES AT HOLE

'd'
4'-0"
MIN SIMP. HOLDOWN,
112" 112" DBL TOP PL 'd' 't' 't' TYP PLYWOOD
SPLICE 16d AT 4" OC NOTES:
MIN MIN MIN AT INTERIOR WALL AT DOOR JAMB 1. NOTCHING, CUTTING & BORING OTHER
AT SPLICE
16d AT 16" OC, BM OR JST MAX DIA EQ TO LESSER THAN SHOWN REQ PRIOR
TYP OF 'd' OR 2" APPROVAL FROM STRUCT ENGINEER.
2. NO NOTCHING, CUTTING OR BORING
OF STUDS WITHIN THE MIDDLE 1/3

6" MIN
1" MIN AFTER 0.5d 1" MIN AFTER OF THE STUD HEIGHT.
BORING MAX BORING 3. DO NOT CUT, NOTCH OR BORE MULTIPLE
SPLICE STUDS OR POSTS AT END OF SHEAR
WALLS.
STUD AT BOT SPLICE

2" MAX
LOCATION, TYP NOTES:
d/6
1. HOLES & NOTCHES NOT PERMITTED FOR d=4" OR LESS. MAX
2. NOTCHES NOT PERMITTED WITHIN MIDDLE THIRD OF SPAN.
3. DO NOT OVER CUT NOTCHES. (2) 16d NAILS
TYPICAL 4. NOTCHES NOT PERMITTED IN BOTTOM OF MEMBER. AT 6" OC TWICE DIA
OF LARGEST HOLE
NOTES: AT EXTERIOR WALL AT INTERIOR CORNER (MIN)
1. SEE GENERAL NOTES FOR ADD'L. NAILING NOT SHOWN.
2. WHERE PLATE DISCONTINUITIES ARE CREATED BY BEAMS & PIPES, ETC. STRAP W/ d
(1) SIMPSON ST6236 UNLESS NOTED OTHERWISE. STRAP MAY BE PLACED ON TOP
OR SIDE OF PLATES AT CONTRACTOR'S OPTION.

TYPICAL TOP PLATE SPLICE NOTCHES & HOLES IN JOIST/BEAMS SHEAR WALL CORNER FRAMING STUD NOTCHING AND HOLES
4 SCALE: N.T.S.
5 SCALE: 1"=1'-0" 6 SCALE: 3/4"1'-0" 7 SCALE: 1"=1'-0"

2x8 OUTRIGGER AT 24" OC


(S) LUS28 HANGER
ROOF SHTHG, SEE PLAN
EN, SEE PLAN (6) 16d NAILS DATE: 3/13/2022

ROOF SHTHG, (S) RBC AT 48" OC


SEE PLAN
EN TO DRAG PRINT:
TRUSS, SEE PLAN
ROOF SHTG,
SEE PLAN (S) A35 EACH SIDE OF ALIGN PRE-MANUF DRAG TRUSS (DRAG
EN, SEE PLAN TRUSS, T&B, TYP BM AT SIM) OVER STRAP BELOW. SEE
PLAN FOR LATERAL FORCE TO BE
CONT 2x BLKG TRANSFERRED FROM SHTHG TO STRAP
LAT PRE-MFR BELOW
2x BLKG
BRACE IF DRAG TRUSS SIGNATURE:
EN, SEE SW (S) LTP4 AT 48" OC ALIGNED
L > 72" NAIL STRAP TO TOP PL OF SW
SCHED W/ WALL,
EN, SEE SW SCHED BEFORE PLACING ROOF
SEE PLAN TRUSSES (DRAG BM AT SIM)
ROOF TRUSS
GABLE TRUSS WITH PARALLEL (S) A35 AT (S) CMST 12
PRE-MANUF RF (S) GBC EA SIDE
VERTS AT 24" OC EA BRACE 24" OC
TRUSS (SCISSOR AS
OCCURS), SEE PLAN
DATE:
2x BRACE AT 48" OC, SEE SW (2) 16d NAILS ROOF TRUSS
WALL SHTHG, SEE SCHED. LATERAL BRACE MID PERPENDICULAR
(S) H2.5A EA TRUSS EQ EQ
SW SCHED SPAN MIN WHEN BRACE
LENGTH > 72" TRUSS SEATED ON
STUD WALL, CONT DBL TOP PL 2x BLKG AT 48" OC TOP PLATE, TYP
SEE PLAN 16d TOENAILS AT 8" OC PRE-MANUF RF W/ 16d TOE NAILS DRAWN BY: LARS WYATT
(2) 10d TOE NAILS
BEAM AS EN, SEE SW SCHED TRUSS, SEE PLAN EN, SEE SHEAR @ 6" OC, TYP
OCCURS BLKG AT BRACING WALL SCHED
WALL SHTHG, SEE
LOCATIONS CONT DBL
SW SCHED
(MIN (2) BAYS), TYP SHEAR WALL, SEE
2x TOP PL SCALE:
BRACE SCHED (S) HGA10 AT 48" OC PLAN & SCHED
CL OF STRAP AT END OF WALL
LENGTH CONT DBL TOP PL
TYPE

1-2x6
UP TO
12'-0"
STUD WALL, SEE PLAN
2x STUD WALL,
SEE PLAN AS NOTED
2-2x6 17'-0"

TYPICAL ROOF TRUSS AT EXTERIOR STUD WALL TYPICAL GABLE ROOF TRUSS BRACE AT EXTERIOR WALL TRUSS TRANSITION AT INTERIOR WALL DRAG TRUSS TO PARALLEL SHEAR WALL
8 SCALE: 1"=1'-0" 9 SCALE: 1"=1'-0" 10 SCALE: 1"=1'-0" 11 SCALE: 1"=1'-0" SHEET No.:

S5
(S) LUS28 HANGER
BLOCKING PER 9/S4 TYP EXCAVATION PIPE SLEEVE
18"
MIN

NO PIPE IN THIS
09-30-2022
EN TO DRAG

HEIGHT
TRUSS, SEE PLAN 1" CLR
ROOF SHTG, TYP
SEE PLAN

OUTLOOKER PER 9/S4


PRE-MFR

2" MIN
DRAG TRUSS
ALIGNED
LOCATION:
W/ WALL,
TYPE 'A' WALL SHEATHING SEE PLAN

4" MIN
ROOF TRUSS 21541 YANKEE VALLEY ROAD
PARALLEL (S) A35 AT
24" OC HIDDEN VALLEY LAKE, CA. 95467
(2) 16d NAILS 1
2

2x BLKG AT 48" OC DO NOT EXCAVATE 4" MIN SECOND PROJECT:


W/ 16d TOE NAILS PARALLEL TO FTG MATCH FTG PLACEMENT
(2) 10d TOE NAILS BELOW THIS LINE WIDTH
EN, SEE SHEAR @ 6" OC, TYP CONC FILL,
DIAG BRACE AT OUTERMOST ROOF DIAG BRACE AT EXTERIOR WALL, WALL SCHED SEE PLACEMENT
CONT DBL SEE NOTE 1
TRUSS, REFER 9/S4 FOR ADDITIONAL INFO REFER 9/S4 FOR ADDITIONAL INFO
2x TOP PL
SHEAR WALL, SEE
SOFFIT BY OTHERS EXTERIOR WALL PER PLAN PLAN & SCHED
NOTES:
1. CONCRETE FILL/LEAN CONCRETE TO BE PLACED A MINIMUM OF 3 DAYS BEFORE PLACING FOOTING.
2x STUD WALL, 2. SEE MECHANICAL AND CIVIL DRAWINGS FOR ADDITIONAL REQUIREMENTS AT SLEEVES.
SEE PLAN

FRONT PORCH ROOF DETAIL TRUSS AT INTERIOR SHEAR WALL PIPE SLEEVE AT FOOTING
1 SCALE: 1"=1'-0" 2 SCALE: 1"=1'-0" 3 SCALE: 3/4"=1'-0"

TRUSS, TRUSS,
SEE PLAN SEE PLAN
FULL DEPTH 2x BLKG. 1'-6" MIN
EA SIDE AT 48" OC 2x8 RIDGE BOARD W/ 2x
KICKERS AT 8'-0" OC MAX
TO MATCH BOT REINF, TYP
ROOF TRUSSES OR
RAFTERS PER PLAN, TYP
CLR.
114"

(S) LSSU HANGER, TYP 1'-6" MIN

2x6 AT 4'-0" OC W/ SIMPSON HTC4 AT 48" OC


CLR.
11 4"

(2) 16d NAILS EA END (SLOT NAILS SHALL BE IN


MIDDLE OF SLOT)

2'-0" MAX TYP


NON-BEARING

'H'
STUD WALL, 2* 'H'
S.A.D.

PARALLEL TO TRUSS (TJI AT SIM.) 2x6 FLAT AT VALLEY & AT


KICKERS W/ (2) 16d INTO
EA ROOF TRUSS, TYP MATCH TRANSV FTG REINF

FTG THK
(S) A34 AT EACH RAFTER
CLR.
11 4"

TRUSS BOTTOM CHORD,


WHEN RAFTER LENGTH
SEE PLAN SIMPSON HTC4 AT 48" OC EXCEEDS 4'-0", TYP
(SLOT NAILS SHALL BE IN
MIDDLE OF SLOT)
STUD WALL, S.A.D.

FTG THK
PERPENDICULAR TO TRUSS (TJI AT SIM.) 2* 'H' FTG THK

NOTE: 2x4 KICKER W/ (2) 16d


DO NOT INSTALL NON-BEARING PARTITIONS UNTIL DEAD LOAD IS IN PLACE (AT ROOF 2x8 RAFTERS AT PROVIDE COLLAR TIE
FACE NAILS AT TOP & (2)
CONSTRUCTION AND WHERE A DEFLECTION SPACE HAS BEEN PROVIDED FOR THIS 16" OC, TYP WHEN RAFTER LENGTH
TOE NAILS AT BOT, TYP
REQUIREMENT MAY BE WAIVED). EXCEEDS 4'-0", TYP
FIX COLLAR TIE W/
(5) 16d EA END, TYP
NON-BEARING PARTITION WALLS AT ROOF TRUSSES CALIFORNIA ROOF FRAMING STEPPED FOOTING DETAIL
4 SCALE: N.T.S.
5 SCALE: N.T.S. 6 SCALE: 1"=1'-0"

DATE: 3/13/2022

PRINT:

SIGNATURE:

DATE:

DRAWN BY: LARS WYATT

SCALE:

AS NOTED
SHEET No.:

S6