Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Code/ Client:

Tube mill
Gaps at trunnion bearings
Place: Date:
Measuring record

Check with feeler gauge

C
B
A Oil intake side
C
B
C A
B

A C
Direction of B
rotation
A
Check with feeler gauge
about ~ 1/3 surface of main contact

without load with load

The bearing bush is supplied by: Polysius Client


Diameter of trunnion: mm
Check of bearing bush: Fixed bearing Floating bearing
The dimensions have been checked: Without load With load
Please mark the fields underlaid in grey

Prior to scraping After scraping


Oil intake side Oil discharge side Oil intake side Oil discharge side

x1 b1 x2 b2 x1 b1 x2 b2 x1 b1 x2 b2 x1 b1 x2 b2
(mm) (mm (mm (mm (mm) (mm) (mm (mm (mm) (mm (mm (mm (mm) (mm) (mm (mm

A A
B B
C C

Nominal size (x1 ; b1 ; x2 ; b2) see data on attached page

During test run the following temperatures have been measured:


after ….hours: 2 4 6 8 10 12
Bearing temperature (°C):

TKIS Client
Signature Signature

TM.09en Vs 00 Page 1
Tube mill
Gaps at trunnion bearings
Nominal dimensions (Page 2)

Oil intake

Trunnion without load b1 Trunnion with load


(installed at full filling of the mill cylinder)

b2 X2

X1 b1
X2
X2

b1 X1

X2 b2

primarily supporting area~1/3


about 90% contact ratio are desirable

Nominal dimensions
Trunnion without load Trunnion with load
Ø Trunnion
x1 b1 x2 b2 x1 b1 x2 b2
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
1000 0.4 10 0.2 150 0.2 10 0.1 150
1200 0.6 10 0.3 150 0.3 10 0.1 150
1300 0.6 10 0.3 200 0.3 10 0.1 200
1400 0.6 10 0.3 200 0.3 10 0.2 200
1500 0.6 10 0.4 200 0.4 10 0.2 200
1650 0.9 10 0.5 250 0.5 10 0.2 250
1800 1.0 10 0.5 250 0.5 10 0.2 250
2000 1.0 10 0.5 300 0.5 10 0.2 300
2200 1.2 10 0.7 300 0.5 10 0.3 300
2400 1.2 10 0.7 300 0.6 10 0.3 300
2600 1.2 10 0.7 400 0.6 10 0.3 400
2800 1.3 10 0.7 400 0.7 10 0.4 400
3000 1.5 10 0.8 450 0.7 10 0.4 450
3200 1.5 10 0.8 450 0.8 10 0.5 450
3400 2.1 10 1.2 450 0.8 10 0.5 450

Tolerance ± 10mm + 10% ± 10mm + 10%

Test run: After 8 hours of operating time, the bearing temperature should stabilize

Bearing temperature: Alarm at 70 ° C.


Shutdown at 75 ° C in the normal case
Deviations from it only after consultation with the specialist department

TM.09en Vs 00 Page 2

You might also like