Project: simulacion con 4 extractores_VF
Variant: Nueva variante de simulación
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 23:47
with v7.2.0
Project summary
Geographical Site Situation Project settings
LALAQUIZ Latitude -5.19 °S Albedo 0.20
Peru Longitude -79.68 °W
Altitude 10 m
Time zone UTC-5
Meteo data
LALAQUIZ
Meteonorm 8.0 (2010-2014), Sat=100% - Sintético
System summary
Stand alone system Stand alone system with batteries
System information
PV Array Battery pack
Nb. of modules 4 units Technology Lead-acid, sealed, Gel
Pnom total 1640 Wp Nb. of units 14 units
Voltage 24 V
Capacity 1330 Ah
Results summary
Available Energy 2845 kWh/year Specific production 1735 kWh/kWp/year Perf. Ratio PR 71.25 %
Used Energy 2445 kWh/year Solar Fraction SF 99.67 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 5
Main results 6
Loss diagram 7
Special graphs 8
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 23:47
with v7.2.0
General parameters
Stand alone system Stand alone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 20 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
User's needs
Daily household consumers
Constant over the year
Average 6.7 kWh/Day
PV Array Characteristics
PV module Battery
Manufacturer Jinkosolar Manufacturer Sonnenschein
Model JKM410M-72H Model Solar S12/230 A
(Original PVsyst database) Technology Lead-acid, sealed, Gel
Unit Nom. Power 410 Wp Nb. of units 7 in parallel x 2 in series
Number of PV modules 4 units Discharging min. SOC 20.0 %
Nominal (STC) 1640 Wp Stored energy 25.5 kWh
Modules 2 Strings x 2 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 24 V
Pmpp 1500 Wp Nominal Capacity 1330 Ah (C10)
U mpp 75 V Temperature Fixed 20 °C
I mpp 20 A
Total PV power
Nominal (STC) 2 kWp
Total 4 modules
Module area 8.0 m²
Cell area 7.1 m²
Array losses
Thermal Loss factor DC wiring losses Serie Diode Loss
Module temperature according to irradiance Global array res. 62 mΩ Voltage drop 0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 0.8 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 23:47
with v7.2.0
Array losses
IAM loss factor
Incidence effect (IAM): Fresnel AR coating, n(glass)=1.526, n(AR)=1.290
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 23:47
with v7.2.0
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 23:47
with v7.2.0
Main results
System Production
Available Energy 2845 kWh/year Specific production 1735 kWh/kWp/year
Used Energy 2445 kWh/year Performance Ratio PR 71.25 %
Excess (unused) 234 kWh/year Solar Fraction SF 99.67 %
Loss of Load Battery aging (State of Wear)
Time Fraction 0.3 % Cycles SOW 86.9 %
Missing Energy 8 kWh/year Static SOW 90.0 %
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 23:47
with v7.2.0
Loss diagram
2097 kWh/m² Global horizontal irradiation
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 23:47
with v7.2.0
Special graphs
Diagrama entrada/salida diaria