4.

0 DESIGN OF WALL
DBR FOR BRIDGE NEAR INTAKE WELL FOR GURUNDIA

OWNER : RURAL WATER SUPPLY & SANITATION DEPARTMENT

- RURAL PIPED WATER SUPPLY TO GURUNDIA BLOCK OF


PROJECT :
SUNDERGARH DISTRICT

DESIGN OF WALL

SELECT GROUP NAME :- WALL_BM

SELECT GROUP NAME :- WALL_SF


DBR FOR BRIDGE NEAR INTAKE WELL FOR GURUNDIA

OWNER : RURAL WATER SUPPLY & SANITATION DEPARTMENT

- RURAL PIPED WATER SUPPLY TO GURUNDIA BLOCK OF


PROJECT :
SUNDERGARH DISTRICT
DESIGN OF WALL

Forces / Stresses from STAAD: (Unfactored values)

Mx Outside (Plt. No. : 600) = 0 Mton.M (-VE) (Load Comb = 42 DL+LL+SL+WC+


Mx Inside (Plt. No. : 1422) = 1.473 Mton.M (Load Comb = 81 DL+LL+SL+WC+

My Outside (Plt. No. : 478) = 1.443 Mton.M (-VE) (Load Comb = 44 DL+LL+SL+WC+
My Inside (Plt. No. : 1410) = 11.054 Mton.M (Load Comb = 81 DL+LL+SL+WC+

Tension Moment corresponding to Mx:


Mxy Outside (Plt. No. : 600) = 0.908 Mton.M (-VE) (Load Comb = 42 DL+LL+SL+WC+
Mxy Inside (Plt. No. : 1422) = 0.14 Mton.M (Load Comb = 81 DL+LL+SL+WC+

Tension Moment corresponding to My:


Mxy Outside (Plt. No. : 478) = 0.4 Mton.M (-VE) (Load Comb = 44 DL+LL+SL+WC+
Mxy Inside (Plt. No. : 1410) = 0.081 Mton.M (Load Comb = 81 DL+LL+SL+WC+

Shear Stress: (Higher of SQX & SQY)


(Plt. No. : 475) = 0.162 N/mm2 (Load Comb = 68

Nett Unfactored Moments:

Along X: (Horizontal Bending)


Outside Moment = Mx (-ve) + Corresponding Mxy outside
= 0.908 Mton.M
Inside Moment = Mx (+ve) + Corresponding Mxy inside
= 1.613 Mton.M

Along Y: (Vertical Bending)


Outside Moment = My (-ve) + Corresponding Mxy outside
= 1.843 Mton.M
Inside Moment = My (+ve) + Corresponding Mxy inside
= 11.135 Mton.M

Nett Unfactored Shear:


Shear Stress = Shear Stress from STAAD x D / d --> ( where D = overall depth, d = effective depth )
= 0.201 N/mm2

Load Factor = 1.5

FACTORED FORCES FOR DESIGN: (Nett Values x Load Factor)

Mx (Mton.M) My (Mton.M) Shear Stress

Outside Inside Outside Inside N/mm2

1.36 2.42 2.76 16.70 0.30

NOTES:
1 -ve Moment in STAAD indicates Tension on outer face of wall when Local Z axis of plate points towards inside of tank

2 Local X axis of Plates are parallel to Horizontal Direction. Hence, reinforcement along X axis corresponds
Horizontal Bending. Also, in plane stresses along X direction Sx (if +ve) correspond to horizontal axial tension in wall.

3 Local Y axis of Plates are parallel to Vertical Direction. Hence, reinforcement along Y axis corresponds
Vertical Bending.
DBR FOR BRIDGE NEAR INTAKE WELL FOR GURUNDIA

OWNER : RURAL WATER SUPPLY & SANITATION DEPARTMENT

- RURAL PIPED WATER SUPPLY TO GURUNDIA BLOCK OF


PROJECT :
SUNDERGARH DISTRICT
DESIGN OF WALL

INPUT DATA
Grade of concrete = M 30
Steel Grade = Fe 500
Density of concrete = 2.5 T /m3
clear cover = 50 mm @ outside
clear cover = 50 mm @ inside
Depth (D) = 300 mm
Breadth (b) = 1000 mm (for unit width)
d eff (Vertical bending) = 242.0 mm
d eff (Horiz. bending) = 242.0 mm

Reinforcement

Mu for Horiz. Bending Tension Outside = 1.36 T-m/m


Ast reqd. @ Horizontal Outside = 131 mm2/m
(pt = 0.05 )

Mu for Horiz. Bending Tension Inside = 2.42 T-m/m


0.5 f ck  4 .6 M u 
Ast  1  1  2 bd
Ast reqd. @ Horizontal Inside = 234 mm2/m
(pt = 0.10 )

Mu for Vertical Bending Tension Outside =


Ast reqd. @ Vertical Outside =
2.76 T-m/m
268 mm2/m
f y  f ck bd 
(pt = 0.11 )

Mu for Vertical Bending Tension Inside = 16.70 T-m/m


Ast reqd. @ Vertical Inside = 1814 mm2/m
(pt = 0.75 )

Ast minimum

Ast Min. @ 0.35% of surface zone = 525 mm2 / m (Each Face Each way)
(Cl.8.1.1 of IS 3370 (Part 2) :2009) { For D < 500, surface zone = D/2 }
(For Tanks > 15m) { For D > 500, surface zone = 250mm }

Ast Min. @ 0.12% of c/s area = 360 mm2 / m (Each way for both faces combined)
(Cl.26.5.2.1 of IS 456:2000) = 180 mm2 / m (Each way for Each Face)

SUMMARY :
Provide Depth (D) = 300 mm

Provide 12 tor @ 200 c/c @ Horizontal Outside


(Ast prov 565 mm2 / m) > 525 mm2 SAFE

Provide 16 tor @ 200 c/c @ Vertical Outside


(Ast prov 1005 mm2 / m) > 525 mm2 SAFE

Provide 12 tor @ 200 c/c @ Horizontal Inside


(Ast prov 565 mm2 / m) > 525 mm2 SAFE

Provide 16 tor @ 100 c/c @ Vertical Inside


(Ast prov 2010 mm2 / m) > 1814 mm2 SAFE
DBR FOR BRIDGE NEAR INTAKE WELL FOR GURUNDIA

OWNER : RURAL WATER SUPPLY & SANITATION DEPARTMENT

- RURAL PIPED WATER SUPPLY TO GURUNDIA BLOCK OF


PROJECT :
SUNDERGARH DISTRICT

CHECK FOR ONEWAY SHEAR :

Maximum tv = 0.30 N/mm2 (Max SQX/SQY from STAAD x Load Factor x D / d )


pt = 0.67 %
tc perm = 0.56 N/mm^2
> tv SAFE