Professional Documents
Culture Documents
4.2 Wall 2 300
4.2 Wall 2 300
4.2 Wall 2 300
0 DESIGN OF WALL
DBR FOR BRIDGE NEAR INTAKE WELL FOR GURUNDIA
DESIGN OF WALL
My Outside (Plt. No. : 478) = 1.443 Mton.M (-VE) (Load Comb = 44 DL+LL+SL+WC+
My Inside (Plt. No. : 1410) = 11.054 Mton.M (Load Comb = 81 DL+LL+SL+WC+
NOTES:
1 -ve Moment in STAAD indicates Tension on outer face of wall when Local Z axis of plate points towards inside of tank
2 Local X axis of Plates are parallel to Horizontal Direction. Hence, reinforcement along X axis corresponds
Horizontal Bending. Also, in plane stresses along X direction Sx (if +ve) correspond to horizontal axial tension in wall.
3 Local Y axis of Plates are parallel to Vertical Direction. Hence, reinforcement along Y axis corresponds
Vertical Bending.
DBR FOR BRIDGE NEAR INTAKE WELL FOR GURUNDIA
INPUT DATA
Grade of concrete = M 30
Steel Grade = Fe 500
Density of concrete = 2.5 T /m3
clear cover = 50 mm @ outside
clear cover = 50 mm @ inside
Depth (D) = 300 mm
Breadth (b) = 1000 mm (for unit width)
d eff (Vertical bending) = 242.0 mm
d eff (Horiz. bending) = 242.0 mm
Reinforcement
Ast minimum
Ast Min. @ 0.35% of surface zone = 525 mm2 / m (Each Face Each way)
(Cl.8.1.1 of IS 3370 (Part 2) :2009) { For D < 500, surface zone = D/2 }
(For Tanks > 15m) { For D > 500, surface zone = 250mm }
Ast Min. @ 0.12% of c/s area = 360 mm2 / m (Each way for both faces combined)
(Cl.26.5.2.1 of IS 456:2000) = 180 mm2 / m (Each way for Each Face)
SUMMARY :
Provide Depth (D) = 300 mm