dual Process Segement Controller

dPSC
General description

Integrating the Local Process Bus and For that reason it is advised to use the
the Global Process Bus dPSC to split two different process
The dPSC is a dual two channel CAN segments, where inter-communication is
gateway. Most often the two channels are necessary.
working in parallel on redundant CAN lines.
Its main task is to process messages from dPSC setup and Configuration
the local CAN segment and send them on All necessary configuration and SW
the global process bus, where they are installation is done via the global CAN.
available for other dPSC’s and System
GateWays (SGW). Commands and Interface with external equipment
download of parameters and software from The dPSC is equipped with a dual serial
any System GateWay to the nodes interface, RS422/485 to communicate with
connected to the local process bus will be other vendors equipment.
handled as well.

Mastership for the local process bus


The dPSC is a node with CANopen master Dual PSC system architecture
capability. The CANopen network
management (NMT) has a redundant
service implemented to guard all nodes
connected to the local Process Bus. If the
communication towards one node fails, the
dPSC will generate a System Failure
message on the global process bus,
identifying the node and the failure.

Redundant Application Process Control


Logic
When the dual PSC is controlling the same
Distributed Processing Units (DPU’s) they
are working in parallel running the same
process algorithm.

Galvanic isolation between process bus


segments
The two CAN channels in the PSC are
based on the ISO 11898 standard, with
optical isolation. Shortcircuit or malfunction
on one CAN channel does not affect the
other CAN channel.

Functions
dPSC Data sheet AD-0296-B
 Redundant routing of messages
between local and global CAN segments  Self check
 Application mastership with active  All parameters stored in module
running backup.  Remote configurable
 PLC algorithm for controlling I/O-signals  No serviceable parts
connected to the local DPU’s.  All connections plugable

Features

Technical description
Connections, pluggable srew terminals:
Supply voltage: 2 serial lines, each 5 terminals 2.5 mm2
18-32 VDC Power 4 terminals 2.5 mm2
Power Consumption: CAN bus A 4 terminals 2.5 mm2
Nominal 12 W Max. 15 W CAN bus B 4 terminals 2.5 mm2
Ambient operational temperature: Specification:
Max temp. range: –15C to +70 C Isolation power port:
Max rel. Humidity: 96% non-condensing 50 VDC continous 50 VAC 1 minute.
Mechanical environment: Isolation:
Dnv class B Power: Complete isolated
IACS E10 ( Direct mout on engines, (DC/DC Converter)
compressors etc. ) CAN: Complete isolated
EMC properties: (Opto coupler)
According IACS E10, EN60945 Serial line: Complete isolated
Ambient storage temperature: (Opto coupler)
-25C to +70C Local Processor
Weight of module: 2xC16X Microcontroller
1.6 kg. CAN Compatible
Mounting: Two independent CAN interface channels
Screws, 4 pcs M5 using Philips SJA1000 CAN controllers
Type Approval: ISO/DIS 11898 high speed physical
DNV, LRS, BV, GL, RINA, NK, ABS, KR, interface with optical isolation
PRS, MRS (Russia), CCS (China)

Dimensions

. Kongsberg Norcontrol reserves the right to change this specification without prior notice

Kongsberg Norcontrol
P.O. Box 1009, N-3194 HORTEN, Norway
Telephone: +47 33 03 20 00 Fax: +47 33 04 22 50
www.Kongsberg.com/Maritime